Improved LFIAs for highly sensitive detection of BNP at point-of-care

Heart failure (HF) has become a major cause of morbidity and mortality with a significant global economic burden. Although well-established clinical tests could provide early diagnosis, access to these tests is limited in developing countries, where a relatively higher incidence of HF is present. This has prompted an urgent need for developing a cost-effective, rapid and robust diagnostic tool for point-of-care (POC) detection of HF. Lateral flow immunoassay (LFIA) has found widespread applications in POC diagnostics. However, the low sensitivity of LFIA limits its ability to detect important HF biomarkers (e.g., brain natriuretic peptide [BNP]) that are normally present in low concentration in blood. To address this issue, we developed an improved LFIA by optimizing the gold nanoparticle (GNP)–antibody conjugate conditions (e.g., the conjugate pH and the amount of added antibody), the diameter of GNP and the concentration of antibody embedded on the test line and modifying the structure of test strip. Through these improvements, the proposed test strip enabled the detection of BNP down to 0.1 ng/mL within 10–15 min, presenting ~15-fold sensitivity enhancement over conventional lateral flow assay. We also successfully applied our LFIA in the analysis of BNP in human serum samples, highlighting its potential use for clinical assessment of HF. The developed LFIA for BNP could rapidly rule out HF with the naked eye, offering tremendous potential for POC test and personalized medicine.

[1]  Zhenpeng Qin,et al.  Significantly improved analytical sensitivity of lateral flow immunoassays by using thermal contrast. , 2012, Angewandte Chemie.

[2]  Reinhard Renneberg,et al.  Development of a quantitative lateral-flow assay for rapid detection of fatty acid-binding protein. , 2003, Journal of immunological methods.

[3]  B. Yawn,et al.  Trends in heart failure incidence and survival in a community-based population. , 2004, JAMA.

[4]  A. Khera,et al.  Forecasting the Future of Cardiovascular Disease in the United States: A Policy Statement From the American Heart Association , 2011, Circulation.

[5]  H. Calkins,et al.  2009 ACCF/AHA focused update on perioperative beta blockade. , 2009, Journal of the American College of Cardiology.

[6]  Min-Gon Kim,et al.  A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I. , 2010, Biosensors & bioelectronics.

[7]  Juewen Liu,et al.  Preparation of aptamer-linked gold nanoparticle purple aggregates for colorimetric sensing of analytes , 2006, Nature Protocols.

[8]  Hui Yang,et al.  Lateral Flow Assay Based on Paper–Hydrogel Hybrid Material for Sensitive Point‐of‐Care Detection of Dengue Virus , 2017, Advanced healthcare materials.

[9]  Jie Hu,et al.  Oligonucleotide-linked gold nanoparticle aggregates for enhanced sensitivity in lateral flow assays. , 2013, Lab on a chip.

[10]  E. Antman,et al.  ACC/AHA PRACTICE GUIDELINES ACC/AHA Guidelines for the Evaluation and Management of Chronic Heart Failure in the Adult: Executive Summary , 2002 .

[11]  Jie Hu,et al.  Sensitive biomolecule detection in lateral flow assay with a portable temperature-humidity control device. , 2016, Biosensors & bioelectronics.

[12]  Alan S Maisel,et al.  Rapid measurement of B-type natriuretic peptide in the emergency diagnosis of heart failure. , 2002, The New England journal of medicine.

[13]  Feng Xu,et al.  Advances in paper-based sample pretreatment for point-of-care testing , 2017, Critical reviews in biotechnology.

[14]  J. Hollander,et al.  B-Type Natriuretic Peptide and Clinical Judgment in Emergency Diagnosis of Heart Failure: Analysis From Breathing Not Properly (BNP) Multinational Study , 2002, Circulation.

[15]  Jie Hu,et al.  An integrated lateral flow assay for effective DNA amplification and detection at the point of care. , 2016, The Analyst.

[16]  Jie Hu,et al.  Polydimethylsiloxane-Paper Hybrid Lateral Flow Assay for Highly Sensitive Point-of-Care Nucleic Acid Testing. , 2016, Analytical chemistry.

[17]  Nuo Duan,et al.  Highly sensitive aptasensor for oxytetracycline based on upconversion and magnetic nanoparticles , 2015 .

[18]  Geertruida A. Posthuma-Trumpie,et al.  Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey , 2009, Analytical and bioanalytical chemistry.

[19]  D. Giannessi,et al.  Measurement of cardiac natriuretic hormones (atrial natriuretic peptide, brain natriuretic peptide, and related peptides) in clinical practice: the need for a new generation of immunoassay methods. , 2000, Clinical chemistry.

[20]  R. O'Kennedy,et al.  Cardiac biomarkers and the case for point-of-care testing. , 2009, Clinical biochemistry.

[21]  M. Vuento,et al.  Affinity immunosensor for milk progesterone: identification of critical parameters. , 1996, Biosensors & bioelectronics.

[22]  Jonathan D Posner,et al.  Two orders of magnitude improvement in detection limit of lateral flow assays using isotachophoresis. , 2014, Analytical chemistry.

[23]  J. Mair,et al.  The Impact of Cardiac Natriuretic Peptide Determination on the Diagnosis and Management of Heart Failure , 2001, Clinical chemistry and laboratory medicine.

[24]  C. Hamm,et al.  Role of B-type natriuretic peptide (BNP) and NT-proBNP in clinical routine , 2005, Heart.

[25]  Fei Li,et al.  Advances in paper-based point-of-care diagnostics. , 2014, Biosensors & bioelectronics.

[26]  Feng Xu,et al.  Paper-based sample-to-answer molecular diagnostic platform for point-of-care diagnostics. , 2015, Biosensors & bioelectronics.

[27]  Gang Li,et al.  Development of an immunochromatographic assay for the rapid detection of chlorpyrifos-methyl in water samples. , 2010, Biosensors & bioelectronics.

[28]  Jean-Louis Marty,et al.  A label free aptasensor for Ochratoxin A detection in cocoa beans: An application to chocolate industries. , 2015, Analytica chimica acta.

[29]  A. Gautier,et al.  C-reactive protein , 2005 .

[30]  M. Emdin,et al.  Comparison of brain natriuretic peptide (BNP) and amino-terminal ProBNP for early diagnosis of heart failure. , 2007, Clinical chemistry.

[31]  L. A. Bonet,et al.  ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012 , 2010, European journal of heart failure.

[32]  A. G. Semenov,et al.  The brain natriuretic peptide (BNP) precursor is the major immunoreactive form of BNP in patients with heart failure. , 2007, Clinical chemistry.

[33]  Jian-hui Jiang,et al.  A sensitive immunosensor using colloidal gold as electrochemical label. , 2007, Talanta.

[34]  Pedro Estrela,et al.  Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics , 2015, Biosensors.

[35]  Michael Böhm,et al.  Kommentar zu den ESC-Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2008 , 2008, European journal of heart failure.

[36]  Jie Hu,et al.  Improved sensitivity of lateral flow assay using paper-based sample concentration technique. , 2016, Talanta.

[37]  Mark D. Huffman,et al.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association. , 2013, Circulation.

[38]  Daniel T Kamei,et al.  Simultaneous concentration and detection of biomarkers on paper. , 2014, Lab on a chip.

[39]  Daniel Levy,et al.  Long-term trends in the incidence of and survival with heart failure. , 2002, The New England journal of medicine.

[40]  M. Emdin,et al.  Cardiac biomarker testing in the clinical laboratory: where do we stand? General overview of the methodology with special emphasis on natriuretic peptides. , 2015, Clinica chimica acta; international journal of clinical chemistry.

[41]  Liberty Sibanda,et al.  Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges. , 2008, Analytica chimica acta.

[42]  Yunqing Ma,et al.  Disposable nucleic acid biosensors based on gold nanoparticle probes and lateral flow strip. , 2009, Analytical chemistry.

[43]  Wen-Chung Yu,et al.  Guidelines of the Taiwan Society of Cardiology ( TSOC ) for the Diagnosis and Treatment of Heart Failure , 2012 .

[44]  Keith Henderson,et al.  Factors influencing the measurement of oestrone sulphate by dipstick particle capture immunoassay. , 2002, Journal of immunological methods.

[45]  Sherine F Cheung,et al.  Paper-Based Systems for Point-of-Care Biosensing , 2015, Journal of laboratory automation.

[46]  Y. Kitaura,et al.  Development of a simple whole blood panel test for detection of human heart-type fatty acid-binding protein. , 2001, Clinical biochemistry.

[47]  Muhammad Sajid,et al.  Designs, formats and applications of lateral flow assay: A literature review , 2015 .

[48]  M. Medina‐Sánchez,et al.  Improving sensitivity of gold nanoparticle-based lateral flow assays by using wax-printed pillars as delay barriers of microfluidics. , 2014, Lab on a chip.

[49]  M. Emdin,et al.  Diagnostic accuracy and prognostic relevance of the measurement of cardiac natriuretic peptides: a review. , 2004, Clinical chemistry.

[50]  O. Velev,et al.  Characterization and optimization of gold nanoparticle-based silver-enhanced immunoassays. , 2007, Analytical chemistry.

[51]  Hui Xu,et al.  Ultrasensitive nucleic acid biosensor based on enzyme-gold nanoparticle dual label and lateral flow strip biosensor. , 2011, Biosensors & bioelectronics.

[52]  Wenjun Gui,et al.  Gold immunochromatographic assay for simultaneous detection of carbofuran and triazophos in water samples. , 2009, Analytical biochemistry.

[53]  Jane Ru Choi,et al.  An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care. , 2016, Lab on a chip.

[54]  Jack H. Ladenson,et al.  Cardiac Troponin I A Marker With High Specificity for Cardiac Injury , 1993, Circulation.

[55]  A. Wu,et al.  The effect of class-specific protease inhibitors on the stabilization of B-type natriuretic peptide in human plasma. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[56]  E. Antman,et al.  Very early risk stratification after thrombolytic therapy with a bedside myoglobin assay and the 12-lead electrocardiogram. , 2000, American heart journal.

[57]  M. Cooper,et al.  A high sensitivity assay for the inflammatory marker C-Reactive protein employing acoustic biosensing , 2008, Journal of nanobiotechnology.

[58]  A. Cossins,et al.  One step visual detection of PCR products with gold nanoparticles and a nucleic acid lateral flow (NALF) device. , 2007, Chemical communications.

[59]  M. Kinoshita,et al.  Plasma brain natriuretic peptide level as a biochemical marker of morbidity and mortality in patients with asymptomatic or minimally symptomatic left ventricular dysfunction. Comparison with plasma angiotensin II and endothelin-1. , 1999, European heart journal.

[60]  Jie Hu,et al.  Paper-based point-of-care testing for diagnosis of dengue infections , 2017, Critical reviews in biotechnology.

[61]  J H Crowe,et al.  Trehalose and sucrose protect both membranes and proteins in intact bacteria during drying , 1995, Applied and environmental microbiology.

[62]  Kristen K. Comfort,et al.  The role of biological fluid and dynamic flow in the behavior and cellular interactions of gold nanoparticles , 2015, Journal of Nanobiotechnology.