Real-time, multiplexed electrochemical DNA detection using an active complementary metal-oxide-semiconductor biosensor array with integrated sensor electronics.

Optical biosensing based on fluorescence detection has arguably become the standard technique for quantifying extents of hybridization between surface-immobilized probes and fluorophore-labeled analyte targets in DNA microarrays. However, electrochemical detection techniques are emerging which could eliminate the need for physically bulky optical instrumentation, enabling the design of portable devices for point-of-care applications. Unlike fluorescence detection, which can function well using a passive substrate (one without integrated electronics), multiplexed electrochemical detection requires an electronically active substrate to analyze each array site and benefits from the addition of integrated electronic instrumentation to further reduce platform size and eliminate the electromagnetic interference that can result from bringing non-amplified signals off chip. We report on an active electrochemical biosensor array, constructed with a standard complementary metal-oxide-semiconductor (CMOS) technology, to perform quantitative DNA hybridization detection on chip using targets conjugated with ferrocene redox labels. A 4 x 4 array of gold working electrodes and integrated potentiostat electronics, consisting of control amplifiers and current-input analog-to-digital converters, on a custom-designed 5 mm x 3 mm CMOS chip drive redox reactions using cyclic voltammetry, sense DNA binding, and transmit digital data off chip for analysis. We demonstrate multiplexed and specific detection of DNA targets as well as real-time monitoring of hybridization, a task that is difficult, if not impossible, with traditional fluorescence-based microarrays.

[1]  John R. Vig UV/ozone cleaning of surfaces , 1976 .

[2]  S. Takenaka,et al.  Ferrocene-oligonucleotide conjugates for electrochemical probing of DNA. , 1996, Nucleic acids research.

[3]  R. Georgiadis,et al.  The effect of surface probe density on DNA hybridization. , 2001, Nucleic acids research.

[4]  R. Thewes,et al.  A fully electronic DNA sensor with 128 positions and in-pixel A/D conversion , 2004, IEEE Journal of Solid-State Circuits.

[5]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[6]  Kia Peyvan,et al.  CombiMatrix oligonucleotide arrays: genotyping and gene expression assays employing electrochemical detection. , 2007, Biosensors & bioelectronics.

[7]  Ronald W. Davis,et al.  Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray , 1995, Science.

[8]  Babak Hassibi,et al.  A statistical model for microarrays, optimal estimation algorithms, and limits of performance , 2006, IEEE Transactions on Signal Processing.

[9]  Технология International Electron Devices Meeting , 2010 .

[10]  Y. Okahata,et al.  Kinetic measurements of DNA hybridization on an oligonucleotide-immobilized 27-MHz quartz crystal microbalance. , 1998, Analytical chemistry.

[11]  H. Hill,et al.  N‐(2‐Ferrocene‐ethyl)maleimide : a new electroactive sulphydryl‐specific reagent for cysteine‐containing peptides and proteins , 1996, FEBS letters.

[12]  K. Shepard,et al.  Charging behavior of single-stranded DNA polyelectrolyte brushes. , 2006, Journal of the American Chemical Society.

[13]  R. Stoughton,et al.  Use of hybridization kinetics for differentiating specific from non-specific binding to oligonucleotide microarrays. , 2002, Nucleic acids research.

[14]  H. Yowanto,et al.  Electronic detection of single-base mismatches in DNA with ferrocene-modified probes. , 2001, Journal of the American Chemical Society.

[15]  A. Horgan,et al.  Physicochemical perspectives on DNA microarray and biosensor technologies. , 2005, Trends in biotechnology.

[16]  A. Steel,et al.  Electrochemical quantitation of DNA immobilized on gold. , 1998, Analytical chemistry.

[17]  S. P. Fodor,et al.  Using oligonucleotide probe arrays to access genetic diversity. , 1995, BioTechniques.

[18]  F. J. Holler,et al.  Principles of Instrumental Analysis , 1973 .

[19]  J. Justin Gooding,et al.  Electrochemical DNA Hybridization Biosensors , 2002 .

[20]  Jeremy S. Lee,et al.  Fc-ssDNA conjugate: electrochemical properties in a borate buffer and adsorption on gold electrode surfaces , 2004 .

[21]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[22]  T. G. Drummond,et al.  Electrochemical DNA sensors , 2003, Nature Biotechnology.

[23]  T. M. Herne,et al.  Characterization of DNA Probes Immobilized on Gold Surfaces , 1997 .

[24]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[25]  J Justin Gooding,et al.  Enzymatic synthesis of redox-labeled RNA and dual-potential detection at DNA-modified electrodes. , 2004, Angewandte Chemie.

[26]  M. Ward,et al.  In Situ Interfacial Mass Detection with Piezoelectric Transducers , 1990, Science.

[27]  A. Ulman,et al.  Formation and Structure of Self-Assembled Monolayers. , 1996, Chemical reviews.

[28]  F W Chu,et al.  Multianalyte microspot immunoassay--microanalytical "compact disk" of the future. , 1991, Clinical chemistry.

[29]  K. M. Millan,et al.  Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode. , 1994, Analytical chemistry.

[30]  David A. Johns,et al.  Analog Integrated Circuit Design , 1996 .

[31]  W. Knoll,et al.  Matching base-pair number dependence of the kinetics of DNA-DNA hybridization studied by surface plasmon fluorescence spectroscopy. , 2005, Biosensors & bioelectronics.

[32]  G. Bhanot,et al.  The importance of thermodynamic equilibrium for high throughput gene expression arrays. , 2003, Biophysical journal.

[33]  Joseph Wang Electrochemical nucleic acid biosensors , 2002 .