Fatigue failure of a star–ratchet gear

Abstract We present an analysis of the fatigue failure of an 18 tooth star–ratchet gear (SRG). The subject gear was implemented in the freewheel assembly of a mountain bicycle. After 6 years of service, the gear failed unexpectedly during a typical off-road ride. The unique geometry of SRGs precluded a simple comparison to existing gear lifetimes. Scanning Electron Microscopy (SEM) analysis of the failed gears showed crack initiation at the root of the gear teeth, followed by fatigue crack propagation and eventual chip-out. A biomechanical analysis of pedaling forces, coupled with explicit power data obtained from instrumented rides over the same trails, in conjunction with a Finite Element Analysis (FEA) of the gear, were used to determine stress amplitudes for fatigue calculations. Energy dispersive spectroscopy (EDS) determined the alloy composition of the gear and thus set the strength and fatigue properties of the gear. Basquin’s law, Goodman’s mean stress correction, and Miner’s rule were used to estimate the lifetime, in bike rides, of the gear. Our analysis led to an estimate of 2288 rides, while failure was reported after roughly 312 rides. Given the uncertainties in fatigue life estimation and service use, we find this estimate acceptable.

[1]  J. Keith Nisbett,et al.  Shigley's Mechanical Engineering Design , 1983 .

[2]  C. Williams,et al.  THE EFFECT OF ELECTROPLATING ON FATIGUE STRENGTH , 1960 .

[3]  K. Mao,et al.  Gear tooth contact analysis and its application in the reduction of fatigue wear , 2007 .

[4]  J Woods Increasing the bending fatigue strength of carburized spur gear teeth by presetting , 1999 .

[5]  Q. J. Yang Fatigue test and reliability design of gears , 1996 .

[6]  P.J.L. Fernandes,et al.  Surface contact fatigue failures in gears , 1997 .

[7]  Y. Murakami Metal Fatigue: Effects of Small Defects and Nonmetallic Inclusions , 2002 .

[8]  Osman Asi,et al.  Fatigue failure of a helical gear in a gearbox , 2006 .

[9]  S Duc,et al.  Validity and Reliability of the PowerTap Mobile Cycling Powermeter when Compared with the SRM Device , 2005, International journal of sports medicine.

[10]  Dwayne Arola,et al.  Estimating the fatigue stress concentration factor of machined surfaces , 2002 .

[11]  R. A. Oriani Hydrogen Embrittlement of Steels , 1978 .

[12]  P.J.L. Fernandes,et al.  Tooth bending fatigue failures in gears , 1996 .

[13]  E. Lunarska,et al.  Effect of plasma nitriding on hydrogen behavior in electroplated chromium coating , 2001 .

[14]  Joseph Marin,et al.  Mechanical behavior of engineering materials , 1962 .

[15]  Herman Jacobus Cornelis Voorwald,et al.  Effect of electroless nickel interlayer on the fatigue strength of chromium electroplated AISI 4340 steel , 2007 .

[16]  G. Mesmacque,et al.  Effect of a Thin Hard Chromium Coating on Fatigue Behaviour Of 4140 Steel , 2004 .

[17]  Neville W. Sachs Understanding the surface features of fatigue fractures: How they describe the failure cause and the failure history , 2005 .

[18]  Abhay K. Jha,et al.  Metallurgical analysis of failed gear , 2002 .