A dynamic parameter to describe the thermal response of buildings to radiant heat gains

Abstract This papers deals with the surface factor , a dynamic parameter that describes the thermal response of a wall to a cyclic radiant heat flux absorbed on its inner surface. Despite it was available since the Seventies in the framework of the admittance procedure, the surface factor has not been fully exploited and, unlike other dynamic thermal properties, it has been very rarely dealt with in the scientific literature. After a concise presentation of the mathematical background, the paper proposes the calculation of the surface factor for common single-layered walls, in order to investigate its sensitivity to the thickness and the thermophysical properties of the slab. Two graphs are presented for an easy and precise determination of the amplitude and the time shift of the surface factor, as a function of the properties of the material. The effect of an insulating layer is also addressed, by varying both its position and thickness. Furthermore, the investigation shows that the values of the film thermal resistance suggested by current Standards are not always appropriate, and may introduce significant inaccuracy. The results provide very useful information for optimizing the response of a wall to periodic heat fluxes acting on its internal surface.

[1]  H. Asan,et al.  Investigation of wall's optimum insulation position from maximum time lag and minimum decrement factor point of view , 2000 .

[2]  A. G. Loudon,et al.  Summertime Temperatures in Buildings Without Air-Conditioning. , 1968 .

[3]  Philip Haves,et al.  Qualitative Comparison of North American and U.K. Cooling Load Calculation Methods , 2000 .

[4]  Andrea Gasparella,et al.  Thermal dynamic transfer properties of the opaque envelope: Analytical and numerical tools for the a , 2011 .

[5]  Luisa F. Cabeza,et al.  Dynamic thermal performance of alveolar brick construction system , 2011 .

[6]  David Allinson,et al.  Assessing the moisture-content-dependent parameters of stabilised earth materials using the cyclic-response admittance method , 2008 .

[7]  Morris Grenfell Davies,et al.  The thermal response of an enclosure to periodic excitation: The CIBSE approach , 1994 .

[8]  Chris Underwood,et al.  Modelling Methods for Energy in Buildings , 2004 .

[9]  Francesco Leccese,et al.  Multi-layered walls design to optimize building-plant interaction , 2004 .

[10]  H. Asan Numerical computation of time lags and decrement factors for different building materials , 2006 .

[11]  Dennis L. Loveday,et al.  The influence on building thermal behavior of the insulation/masonry distribution in a three-layered construction , 1997 .

[12]  Hazim B. Awbi,et al.  Calculation of convective heat transfer coefficients of room surfaces for natural convection , 1998 .

[13]  Morris Grenfell Davies The thermal admittance of layered walls , 1973 .

[14]  中原 信生,et al.  Building simulation '99 : Sixth International IBPSA Conference, September 13-15, 1999 Kyoto, Japan : proceedings , 1999 .