Effects of Dielectrophoresis on Growth, Viability and Immuno-reactivity of Listeria monocytogenes

Dielectrophoresis (DEP) has been regarded as a useful tool for manipulating biological cells prior to the detection of cells. Since DEP uses high AC electrical fields, it is important to examine whether these electrical fields in any way damage cells or affect their characteristics in subsequent analytical procedures. In this study, we investigated the effects of DEP manipulation on the characteristics of Listeria monocytogenes cells, including the immuno-reactivity to several Listeria- specific antibodies, the cell growth profile in liquid medium, and the cell viability on selective agar plates. It was found that a 1-h DEP treatment increased the cell immuno-reactivity to the commercial Listeria species-specific polyclonal antibodies (from KPL) by ~31.8% and to the C11E9 monoclonal antibodies by ~82.9%, whereas no significant changes were observed with either anti-InlB or anti-ActA antibodies. A 1-h DEP treatment did not cause any change in the growth profile of Listeria in the low conductive growth medium (LCGM); however, prolonged treatments (4 h or greater) caused significant delays in cell growth. The results of plating methods showed that a 4-h DEP treatment (5 MHz, 20 Vpp) reduced the viable cell numbers by 56.8–89.7 %. These results indicated that DEP manipulation may or may not affect the final detection signal in immuno-based detection depending on the type of antigen-antibody reaction involved. However, prolonged DEP treatment for manipulating bacterial cells could produce negative effects on the cell detection by growth-based methods. Careful selection of DEP operation conditions could avoid or minimize negative effects on subsequent cell detection performance.

[1]  U. Zimmermann,et al.  Trapping of viruses in high-frequency electric field cages , 1996, Naturwissenschaften.

[2]  Mehmet Toner,et al.  Design and analysis of extruded quadrupolar dielectrophoretic traps , 2003 .

[3]  T. Geng,et al.  Expression of cellular antigens of Listeria monocytogenes that react with monoclonal antibodies C11E9 and EM‐7G1 under acid‐, salt‐ or temperature‐induced stress environments , 2003, Journal of applied microbiology.

[4]  Peter R. C. Gascoyne,et al.  Dielectrophoretic manipulation of particles , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[5]  Andreas Lübbert,et al.  Automation in Biotechnology , 2001 .

[6]  A. Sowers Membrane skeleton restraint of surface shape change during fusion of erythrocyte membranes: evidence from use of osmotic and dielectrophoretic microforces as probes. , 1995, Biophysical journal.

[7]  E. Neumann,et al.  Electroporation and Electrofusion in Cell Biology , 1989, Springer US.

[8]  A. Bhunia,et al.  Effect of environmental stresses on antibody‐based detection of Escherichia coli O157:H7, Salmonella enterica serotype Enteritidis and Listeria monocytogenes , 2006, Journal of applied microbiology.

[9]  J. Voldman,et al.  Holding forces of single-particle dielectrophoretic traps. , 2001, Biophysical journal.

[10]  R. Pethig Application of A.C. electrical fields to the manipulation and characterisation of cells , 1991 .

[11]  Bernhard Wagner,et al.  Radio-frequency microtools for particle and live cell manipulation , 1994, Naturwissenschaften.

[12]  M. Heller,et al.  Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip. , 1998, Analytical chemistry.

[13]  J. Hospodka,et al.  Quantitative physiology of Penicillium chrysogenum in penicillin fermentation , 1980 .

[14]  Cengiz S. Ozkan,et al.  Separation of individual neurons using dielectrophoretic alternative current fields , 2004, Journal of Neuroscience Methods.

[15]  G. Fuhr,et al.  Cell manipulation and cultivation under a.c. electric field influence in highly conductive culture media. , 1994, Biochimica et biophysica acta.

[16]  Thomas B. Jones,et al.  Active feedback‐controlled dielectrophoretic levitation , 1986 .

[17]  R. Davalos,et al.  An insulator-based (electrodeless) dielectrophoretic concentrator for microbes in water. , 2005, Journal of microbiological methods.

[18]  R. Bashir,et al.  Impedance microbiology-on-a-chip: microfluidic bioprocessor for rapid detection of bacterial metabolism , 2005, Journal of Microelectromechanical Systems.

[19]  Rashid Bashir,et al.  Conductivity and pH dual detection of growth profile of healthy and stressed Listeria monocytogenes. , 2005, Biotechnology and bioengineering.

[20]  A. Bhunia,et al.  Differential expression of InlB and ActA in Listeria monocytogenes in selective and nonselective enrichment broths , 2008, Journal of applied microbiology.

[21]  G. Gradl,et al.  A 3-D microelectrode system for handling and caging single cells and particles , 1999 .

[22]  Junya Suehiro,et al.  Selective detection of specific bacteria using dielectrophoretic impedance measurement method combined with an antigen-antibody reaction , 2003 .

[23]  Junya Suehiro,et al.  Selective detection of bacteria by a dielectrophoretic impedance measurement method using an antibody-immobilized electrode chip , 2006 .

[24]  Sophia Adamia,et al.  A combined dielectrophoresis, traveling wave dielectrophoresis and electrorotation microchip for the manipulation and characterization of human malignant cells. , 2004, Journal of microbiological methods.

[25]  L. Mir,et al.  Cell electropermeabilization: a new tool for biochemical and pharmacological studies. , 1993, Biochimica et biophysica acta.

[26]  Junya Suehiro,et al.  Improvement of electric pulse shape for electropermeabilization-assisted dielectrophoretic impedance measurement for high sensitive bacteria detection , 2005 .

[27]  D. Armstrong,et al.  Separating microbes in the manner of molecules. 1. Capillary electrokinetic approaches. , 1999, Analytical chemistry.

[28]  Peter R C Gascoyne,et al.  Dielectrophoretic Separation of Cancer Cells from Blood. , 1997, IEEE transactions on industry applications.

[29]  Rashid Bashir,et al.  Performance evaluation of a low conductive growth medium (LCGM) for growth of healthy and stressed Listeria monocytogenes and other common bacterial species. , 2006, International journal of food microbiology.

[30]  J. Voldman,et al.  Dielectrophoretic registration of living cells to a microelectrode array. , 2004, Biosensors & bioelectronics.

[31]  M. G. Johnson,et al.  Development and characterization of a monoclonal antibody specific for Listeria monocytogenes and Listeria innocua , 1991, Infection and immunity.

[32]  T. Geng,et al.  Selective enrichment media affect the antibody-based detection of stress-exposed Listeria monocytogenes due to differential expression of antibody-reactive antigens identified by protein sequencing. , 2006, Journal of food protection.

[33]  T. Tsong,et al.  Electroporation of cell membranes. , 1991, Biophysical journal.

[34]  L. Chernomordik,et al.  Reversible large-scale deformations in the membranes of electrically-treated cells: electroinduced bleb formation. , 1990, Biochimica et biophysica acta.

[35]  Rashid Bashir,et al.  A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes. , 2006, Lab on a chip.

[36]  Y. Huang,et al.  Differences in the AC electrodynamics of viable and non-viable yeast cells determined through combined dielectrophoresis and electrorotation studies. , 1992, Physics in medicine and biology.

[37]  Chunxiang Xu,et al.  Dielectrophoresis of human red cells in microchips , 1999, Electrophoresis.

[38]  Burçak Alp,et al.  Building structured biomaterials using AC electrokinetics. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[39]  M. Heller,et al.  Electric manipulation of bioparticles and macromolecules on microfabricated electrodes. , 2001, Analytical chemistry.

[40]  R. Pethig,et al.  Applications of dielectrophoresis in biotechnology. , 1997, Trends in biotechnology.

[41]  P. Gascoyne,et al.  Particle separation by dielectrophoresis , 2002, Electrophoresis.

[42]  P. Marszalek,et al.  Experimental verification of a theoretical treatment of the mechanism of dielectrophoresis , 1989 .

[43]  C. Hedberg,et al.  Food-related illness and death in the United States. , 1999, Emerging infectious diseases.

[44]  R. Pethig,et al.  Dielectrophoretic separation of bacteria using a conductivity gradient. , 1996, Journal of biotechnology.

[45]  R. Pethig,et al.  The dielectrophoresis enrichment of CD34+ cells from peripheral blood stem cell harvests. , 1996, Bone marrow transplantation.

[46]  T. Reese,et al.  Changes in membrane structure induced by electroporation as revealed by rapid-freezing electron microscopy. , 1990, Biophysical journal.

[47]  Hong Wang,et al.  DETECTION OF VIABLE LISTERIA MONOCYTOGENES IN MILK USING AN ELECTROCHEMICAL METHOD , 2003 .

[48]  M. Heller,et al.  Dielectrophoretic cell separation and gene expression profiling on microelectronic chip arrays. , 2002, Analytical chemistry.

[49]  X. Wang,et al.  Role of peroxide in AC electrical field exposure effects on friend murine erythroleukemia cells during dielectrophoretic manipulations. , 1999, Biochimica et biophysica acta.

[50]  Ronald Pethig,et al.  Dielectrophoretic characterization and separation of micro-organisms , 1994 .

[51]  Junya Suehiro,et al.  Selective detection of viable bacteria using dielectrophoretic impedance measurement method , 2003 .

[52]  T. Tsong,et al.  Dielectrophoresis and electrorotation of neurospora slime and murine myeloma cells. , 1991, Biophysical journal.

[53]  Burçak Alp,et al.  Construction of biofilms with defined internal architecture using dielectrophoresis and flocculation. , 2003, Biotechnology and bioengineering.

[54]  Chuanmin Ruan,et al.  Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance. , 2003, Biosensors & bioelectronics.

[55]  G Medoro,et al.  Levitation and movement of human tumor cells using a printed circuit board device based on software-controlled dielectrophoresis. , 2003, Biotechnology and bioengineering.

[56]  R. Pethig,et al.  Separation of viable and non-viable yeast using dielectrophoresis. , 1994, Journal of biotechnology.

[57]  K. Kaler,et al.  Dielectrophoretic spectra of single cells determined by feedback-controlled levitation. , 1990, Biophysical journal.

[58]  F F Becker,et al.  Separation of human breast cancer cells from blood by differential dielectric affinity. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[59]  U. Zimmermann,et al.  Electropermeabilization and fluorescent tracer exchange: the role of whole-cell capacitance. , 1995, Cytometry.

[60]  Michael P Hughes,et al.  Early detection of oral cancer - Is dielectrophoresis the answer? , 2007, Oral oncology.

[61]  R. Astumian,et al.  Electroconformational coupling and membrane protein function. , 1987, Progress in biophysics and molecular biology.

[62]  Yanbin Li,et al.  Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium. , 2004, Biosensors & bioelectronics.

[63]  Roberto Guerrieri,et al.  Applications to Cancer Research of “Lab-on-a-chip” Devices Based on Dielectrophoresis (DEP) , 2003, Technology in cancer research & treatment.

[64]  W. B. Betts,et al.  The potential of dielectrophoresis for the real-time detection of microorganisms in foods , 1995 .

[65]  R. Bashir,et al.  Dielectrophoretic separation and manipulation of live and heat-treated cells of Listeria on microfabricated devices with interdigitated electrodes , 2002 .