Electrospray sample injection for single-particle imaging with x-ray lasers

Electrospray contaminant-free delivery of proteins to x-ray laser heralds the start of single-protein x-ray diffractive imaging. The possibility of imaging single proteins constitutes an exciting challenge for x-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available x-ray lasers and, as we demonstrate here, contamination of the aerosolized molecules by nonvolatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet size during aerosolization. Here, we show that, with our electrospray injector, we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next-generation x-ray lasers, constitute an important stepping stone toward the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.

[1]  Garth J. Williams,et al.  Single mimivirus particles intercepted and imaged with an X-ray laser , 2011, Nature.

[2]  J. Fenn,et al.  Electrospray ion source: another variation on the free-jet theme , 1984 .

[3]  D. Schneider,et al.  Linac Coherent Light Source data analysis using psana , 2016 .

[4]  J R Fienup,et al.  Phase retrieval algorithms: a comparison. , 1982, Applied optics.

[5]  W. H. Benner,et al.  Single particle X-ray diffractive imaging. , 2007, Nano letters.

[6]  Carl Nettelblad,et al.  Hummingbird: monitoring and analyzing flash X-ray imaging experiments in real time1 , 2016, Journal of applied crystallography.

[7]  I. Andersson,et al.  Crystallization and preliminary x-ray studies of spinach ribulose 1,5-bisphosphate carboxylase/oxygenase complexed with activator and a transition state analogue. , 1983, The Journal of biological chemistry.

[8]  Filipe R N C Maia,et al.  Rayleigh-scattering microscopy for tracking and sizing nanoparticles in focused aerosol beams , 2018, IUCrJ.

[9]  R. Campargue Progress in overexpanded supersonic jets and skimmed molecular beams in free-jet zones of silence , 1984 .

[10]  J. Hajdu,et al.  Potential for biomolecular imaging with femtosecond X-ray pulses , 2000, Nature.

[11]  Tomas Ekeberg,et al.  Condor: a simulation tool for flash X-ray imaging , 2016, Journal of applied crystallography.

[12]  Alfonso M Gañán-Calvo,et al.  Revision of capillary cone-jet physics: electrospray and flow focusing. , 2009, Physical review. E, Statistical, nonlinear, and soft matter physics.

[13]  Anton Barty,et al.  Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses , 2017, IUCrJ.

[14]  J. Miao,et al.  Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens , 1999, Nature.

[15]  Georg Weidenspointner,et al.  Femtosecond free-electron laser x-ray diffraction data sets for algorithm development. , 2011, Optics express.

[16]  M. Mann,et al.  Electrospray ionization for mass spectrometry of large biomolecules. , 1989, Science.

[17]  Anton Barty,et al.  Imaging single cells in a beam of live cyanobacteria with an X-ray laser , 2015, Nature Communications.

[18]  J. Miao,et al.  Beyond crystallography: Diffractive imaging using coherent x-ray light sources , 2015, Science.

[19]  Anton Barty,et al.  High-throughput imaging of heterogeneous cell organelles with an X-ray laser , 2014, Nature Photonics.

[20]  John C. H. Spence,et al.  Liquid capillary micro/nanojets in free-jet expansion. , 2010, Small.

[21]  D. R. Luke Relaxed Averaged Alternating Reflections for Diffraction Imaging , 2004, math/0405208.

[22]  David Y. H. Pui,et al.  Electrospraying of conducting liquids for monodisperse aerosol generation in the 4 nm to 1.8 μm diameter range , 1995 .

[23]  C. Robinson,et al.  Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry , 2007, Nature Protocols.

[24]  Nora Berrah,et al.  The LAMP instrument at the Linac Coherent Light Source free-electron laser. , 2018, The Review of scientific instruments.

[25]  S. Awel,et al.  Optimizing aerodynamic lenses for single-particle imaging , 2017, Journal of Aerosol Science.

[26]  Marc Messerschmidt,et al.  The Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source , 2015, Journal of synchrotron radiation.

[27]  R. Santra,et al.  The linac coherent light source single particle imaging road map , 2015, Structural dynamics.

[28]  S. Kaufman,et al.  Macromolecule analysis based on electrophoretic mobility in air:  globular proteins. , 1996, Analytical chemistry.

[29]  K. Schmidt,et al.  Gas dynamic virtual nozzle for generation of microscopic droplet streams , 2008, 0803.4181.

[30]  David van der Spoel,et al.  Hawk: the image reconstruction package for coherent X‐ray diffractive imaging , 2010 .

[31]  A. H. Walenta,et al.  Large-format, high-speed, X-ray pnCCDs combined with electron and ion imaging spectrometers in a multipurpose chamber for experiments at 4th generation light sources , 2010 .

[32]  Jean-Michel Claverie,et al.  Three-dimensional reconstruction of the giant mimivirus particle with an x-ray free-electron laser. , 2015, Physical review letters.

[33]  C. Fang-Yen,et al.  Tomographic phase microscopy , 2008, Nature Methods.

[34]  Alfonso M. Gañán-Calvo,et al.  Generation of Steady Liquid Microthreads and Micron-Sized Monodisperse Sprays in Gas Streams , 1998 .

[35]  S. Kaufman,et al.  Droplet size measurements of various nebulizers usingdifferential electrical mobility particle sizer , 1991 .

[36]  J. Hajdu,et al.  Electrospray time-of-flight mass spectrometry of the intact MS2 virus capsid , 2000 .