Optimization Design Method and Experimental Validation of a Solar PVT Cogeneration System Based on Building Energy Demand

Photovoltaic-thermal (PVT) technology refers to the integration of a photovoltaic (PV) and a conventional solar thermal collector, representing the deep exploitation and utilization of solar energy. In this paper, we evaluate the performance of a solar PVT cogeneration system based on specific building energy demand using theoretical modeling and experimental study. Through calculation and simulation, the dynamic heating load and electricity load is obtained as the basis of the system design. An analytical expression for the connection of PVT collector array is derived by using basic energy balance equations and thermal models. Based on analytical results, an optimized design method was carried out for the system. In addition, the fuzzy control method of frequency conversion circulating water pumps and pipeline switching by electromagnetic valves is introduced in this paper to maintain the system at an optimal working point. Meanwhile, an experimental setup is established, which includes 36 PVT collectors with every 6 PVT collectors connected in series. The thermal energy generation, thermal efficiency, power generation and photovoltaic efficiency have been given in this paper. The results demonstrate that the demonstration solar PVT cogeneration system can meet the building energy demand in the daytime in the heating season.

[1]  T. Bergene,et al.  Model calculations on a flat-plate solar heat collector with integrated solar cells , 1995 .

[2]  J. B. Rishel,et al.  Proper control of HVAC variable speed pumps , 1998 .

[3]  H. P. Garg,et al.  SOME ASPECTS OF A PV/T COLLECTOR/FORCED CIRCULATION FLAT PLATE SOLAR WATER HEATER WITH SOLAR CELLS , 1995 .

[4]  Tin-Tai Chow,et al.  Performance analysis of photovoltaic-thermal collector by explicit dynamic model , 2003 .

[5]  Arvind Tiwari,et al.  Performance evaluation of solar PV/T system: An experimental validation , 2006 .

[6]  Zhen Lu,et al.  Fuzzy control model and simulation of supply air system in a test rig of low-temperature hot-water radiator system , 2010 .

[7]  B. E. Cole-Appel,et al.  Calculation of performance of N collectors in series from test data on a single collector , 1979 .

[8]  Shyam,et al.  Performance evaluation of N-photovoltaic thermal (PVT) water collectors partially covered by photovoltaic module connected in series: An experimental study , 2016 .

[9]  Francesco Calise,et al.  Design, Simulation and Experimental Investigation of a Solar System Based on PV Panels and PVT Collectors , 2016 .

[10]  L. W. Florschuetz Extension of the Hottel-Whillier model to the analysis of combined photovoltaic/thermal flat plate collectors , 1976 .

[11]  Saffa Riffat,et al.  Building integrated solar thermal collectors – A review , 2015 .

[12]  Ha Herbert Zondag,et al.  The yield of different combined PV-thermal collector designs , 2003 .

[13]  G. N. Tiwari,et al.  Analysis of different configurations of flat plate water collectors connected in series , 2008 .

[14]  Jie Ji,et al.  Hybrid photovoltaic-thermosyphon water heating system for residential application , 2006 .

[15]  Jili Zhang,et al.  Experimental study on a novel fuzzy control method for static pressure reset based on the maximum damper position feedback , 2015 .

[16]  K. Touafek,et al.  Theoretical and Experimental Studies of a New Configuration of Photovoltaic–Thermal Collector , 2017 .

[17]  Sanjay Agrawal,et al.  Efficiency maximization and performance evaluation of hybrid dual channel semitransparent photovoltaic thermal module using fuzzyfied genetic algorithm , 2016 .

[18]  Francesco Calise,et al.  Design and dynamic simulation of a novel solar trigeneration system based on hybrid photovoltaic/thermal collectors (PVT) , 2012 .

[19]  Saffa Riffat,et al.  Performance evaluation and techno-economic analysis of a novel building integrated PV/T roof collector: An experimental validation , 2014 .

[20]  R. Mishra,et al.  Energy and exergy analysis of hybrid photovoltaic thermal water collector for constant collection temperature mode , 2013 .

[21]  Tin-Tai Chow,et al.  Performance evaluation and economic analysis of a full scale water-based photovoltaic/thermal (PV/T) system in an office building , 2016 .

[22]  Swapnil Dubey,et al.  Analysis of PV/T flat plate water collectors connected in series , 2009 .

[23]  V. Ramachandra Raju,et al.  Effect of flat plate collectors in series on performance of active solar still for Indian coastal climatic condition , 2016 .

[24]  Swapnil Dubey,et al.  Thermal modeling of a combined system of photovoltaic thermal (PV/T) solar water heater , 2008 .

[25]  Tin-Tai Chow,et al.  Hybrid photovoltaic and thermal solar-collector designed for natural circulation of water , 2006 .

[26]  Shyam,et al.  Analytical expression of temperature dependent electrical efficiency of N-PVT water collectors connected in series , 2015 .

[27]  Saffa Riffat,et al.  Performance Analysis of a Combined Building Integrated PV/T Collector with a Liquid Desiccant Enhanced Dew Point Cooler☆ , 2016 .