Immobilization of myoglobin on Au nanoparticle-decorated carbon nanotube/polytyramine composite as a mediator-free H2O2 and nitrite biosensor

A novel composite film was designed for use as a highly selective mediator-free amperometric biosensor, and a method was created for accomplishing direct electrochemistry of myoglobin on a multi-walled carbon nanotube and tyramine-modified composite decorated with Au nanoparticles on a glassy carbon electrode. The ultraviolet-visible and electrochemical impedance spectroscopy results showed that myoglobin retained its native conformation in the interaction with Au-PTy-f-MWCNT. The surface coverage of Mb-heme-Fe(II)/(III) immobilized on Au-PTy-f-MWCNT and the heterogeneous electron-transfer rate constant were 2.12 × 10−9 mol cm−2 and 4.86 s−1, respectively, indicating a higher loading capacity of the nanocomposite for direct electron transfer of Mb onto the electrode surface. The proposed Mb/Au-PTy-f-MWCNT biofilm exhibited excellent electrocatalytic behavior toward the reduction of H2O2 and the oxidation of nitrite with linear ranges of 2 to 5000 μM and 1 to 8000 μM and lower detection limits of 0.01 μM and 0.002 μM, respectively. An apparent Michaelis-Menten constant of 0.12 mM indicated that the Mb immobilized on the Au-PTy-f-MWCNT film retained its native activity. This biosensor can be successfully applied to detect H2O2 and nitrite in disinfectant cream, eye drops, pickle juice, and milk samples.

[1]  A. Safavi,et al.  Hydrogen peroxide biosensor based on a myoglobin/hydrophilic room temperature ionic liquid film. , 2010, Analytical biochemistry.

[2]  Hong Chen,et al.  Direct electrochemistry and electrocatalysis of myoglobin immobilized on zirconia/multi-walled carbon nanotube nanocomposite , 2010 .

[3]  Xinsheng Liu,et al.  Nonenzymatic nitrite sensor based on a titanium dioxide nanoparticles/ionic liquid composite electrode , 2014 .

[4]  Changqing Sun,et al.  Hydrogen peroxide biosensor based on myoglobin/colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film , 2006 .

[5]  Hitoshi Kodamatani,et al.  Selective determination method for measurement of nitrite and nitrate in water samples using high-performance liquid chromatography with post-column photochemical reaction and chemiluminescence detection. , 2009, Journal of chromatography. A.

[6]  G. Rivas,et al.  Glucose biosensors based on the immobilization of glucose oxidase and polytyramine on rodhinized glassy carbon and screen printed electrodes , 2006 .

[7]  A. Salimi,et al.  Amperometric detection of nitrite, iodate and periodate at glassy carbon electrode modified with catalase and multi-wall carbon nanotubes , 2007 .

[8]  Wei Sun,et al.  Electrochemistry of myoglobin in Nafion and multi-walled carbon nanotubes modified carbon ionic liquid electrode. , 2009, Bioelectrochemistry.

[9]  Jianrong Chen,et al.  Electrodeposited nonconducting polytyramine for the development of glucose biosensors. , 2005, Analytical biochemistry.

[10]  Hui Chen,et al.  Peroxynitrous-acid-induced chemiluminescence of fluorescent carbon dots for nitrite sensing. , 2011, Analytical chemistry.

[11]  Z. Shih,et al.  Synthesis of Cu9S8/carbon nanotube nanocomposites with high electrocatalytic activity for the oxygen reduction reaction , 2014 .

[12]  Jeong-Woo Choi,et al.  An enzymatic biosensor for hydrogen peroxide based on CeO2 nanostructure electrodeposited on ITO surface. , 2013, Biosensors & bioelectronics.

[13]  Q. Ma,et al.  The immobilization of Cytochrome c on MWNT–PAMAM–Chit nanocomposite incorporated with DNA biocomposite film modified glassy carbon electrode for the determination of nitrite , 2010 .

[14]  D. B. Hibbert,et al.  Immobilisation of enzyme throughout a polytyramine matrix: a versatile procedure for fabricating biosensors , 1999 .

[15]  Yongfeng Li,et al.  Plasma synthesis of carbon nanotube-gold nanohybrids: efficient catalysts for green oxidation of silanes in water , 2014 .

[16]  S. Iijima Helical microtubules of graphitic carbon , 1991, Nature.

[17]  Zong Dai,et al.  Direct electrochemistry of myoglobin based on ionic liquid-clay composite films. , 2009, Biosensors & bioelectronics.

[18]  Yikai Zhou,et al.  A novel nitrite biosensor based on single-layer graphene nanoplatelet-protein composite film. , 2011, Biosensors & bioelectronics.

[19]  Zhi-xia He,et al.  Direct electrochemistry and electrocatalysis of myoglobin in dodecyltrimethylammonium bromide film modified carbon ceramic electrode , 2011 .

[20]  Qinglin Sheng,et al.  Direct Electron Transfer of Horseradish Peroxidase in Gellan Gum–Hydrophilic Ionic Liquid Gel Film , 2009 .

[21]  Shen-Ming Chen,et al.  Direct electrochemistry of cytochrome c immobilized on a graphene oxide–carbon nanotube composite for picomolar detection of hydrogen peroxide , 2014 .

[22]  N. Hu,et al.  Fabrication of electroactive layer-by-layer films of myoglobin with gold nanoparticles of different sizes. , 2006, The journal of physical chemistry. B.

[23]  Shen-Ming Chen,et al.  Direct electrochemistry of myoglobin at reduced graphene oxide-multiwalled carbon nanotubes-platinum nanoparticles nanocomposite and biosensing towards hydrogen peroxide and nitrite. , 2014, Biosensors & bioelectronics.

[24]  Yancai Li,et al.  Direct electrochemistry and electrocatalysis of myoglobin-based nanocomposite membrane electrode. , 2011, Bioelectrochemistry.

[25]  K. Jiao,et al.  Highly sensitive electrochemical impedance sensing of PEP gene based on integrated Au-Pt alloy nanoparticles and polytyramine. , 2012, Colloids and surfaces. B, Biointerfaces.

[26]  Jianbin Zheng,et al.  Direct electrochemistry of myoglobin based on DNA accumulation on carbon ionic liquid electrode , 2009 .

[27]  Selvakumar Palanisamy,et al.  Direct electrochemistry of myoglobin at silver nanoparticles/myoglobin biocomposite: Application for hydrogen peroxide sensing , 2014 .

[28]  Hui Zhang,et al.  A facile method for the immobilization of myoglobin on multi-walled carbon nanotubes: Poly(methacrylic acid-co-acrylamide) nanocomposite and its application for direct bio-detection of H2O2 , 2014 .

[29]  Ashok M. Biradar,et al.  Synthesis and electrochemical characterization of myoglobin-antibody protein immobilized self-assembled gold nanoparticles on ITO-glass plate , 2012 .

[30]  Jianbin Zheng,et al.  Direct Electron Transfer and Electrocatalysis of Myoglobin Based on its Direct Immobilization on Carbon Ionic Liquid Electrode , 2009 .

[31]  S. Epstein,et al.  Nitrosamines as Environmental Carcinogens , 1970, Nature.

[32]  Erol Akyilmaz,et al.  MWCNT-cysteamine-Nafion modified gold electrode based on myoglobin for determination of hydrogen peroxide and nitrite. , 2015, Bioelectrochemistry.

[33]  G. S. Wilson,et al.  Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer , 1980 .

[34]  Changqing Sun,et al.  Amperometric nitrite sensor based on hemoglobin/colloidal gold nanoparticles immobilized on a glassy carbon electrode by a titania sol-gel film , 2005, Analytical and bioanalytical chemistry.

[35]  José M. Pingarrón,et al.  A biosensor based on cytochrome c immobilization on a poly-3-methylthiophene/multi-walled carbon nanotubes hybrid-modified electrode. Application to the electrochemical determination of nitrite , 2010 .

[36]  Qing Zhang,et al.  Porous nanosheet-based ZnO microspheres for the construction of direct electrochemical biosensors. , 2008, Biosensors & bioelectronics.

[37]  J. Kendrew,et al.  A Three-Dimensional Model of the Myoglobin Molecule Obtained by X-Ray Analysis , 1958, Nature.

[38]  Jian-Rong Zhang,et al.  Direct electrochemistry and electrocatalysis of myoglobin based on silica-coated gold nanorods/room temperature ionic liquid/silica sol-gel composite film. , 2009, Talanta.

[39]  Qixian Zhang,et al.  The synthesis of ionic-liquid-functionalized multiwalled carbon nanotubes decorated with highly dispersed Au nanoparticles and their use in oxygen reduction by electrocatalysis , 2008 .

[40]  Shen-Ming Chen,et al.  Highly selective amperometric nitrite sensor based on chemically reduced graphene oxide modified electrode , 2012 .

[41]  D. Pang,et al.  Direct electrochemistry and electrocatalysis of heme-proteins entrapped in agarose hydrogel films. , 2004, Biosensors & bioelectronics.

[42]  Ying Yu,et al.  Electrochemistry and electrocatalysis of myoglobin on carbon coated Fe3O4 nanospindle modified carbon ionic liquid electrode , 2012 .

[43]  Maogen Zhang,et al.  Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes. , 2004, Analytical chemistry.

[44]  E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems , 1979 .

[45]  Shen-ming Chen,et al.  Direct electrochemistry of catalase at multiwalled carbon nanotubes-nafion in presence of needle shaped DDAB for H2O2 sensor. , 2009, Talanta.

[46]  James Alastair McLaughlin,et al.  High resolution XPS characterization of chemical functionalised MWCNTs and SWCNTs , 2005 .

[47]  Jianbin Zheng,et al.  Direct electrochemistry and electrocatalysis of myoglobin immobilized in hyaluronic acid and room temperature ionic liquids composite film , 2008 .

[48]  Wei Sun,et al.  Direct Electrochemistry of Myoglobin in a Nafion‐Ionic Liquid Composite Film Modified Carbon Ionic Liquid Electrode , 2009 .

[49]  Jianbin Zheng,et al.  TiC nanoparticles-chitosan composite film for the direct electron transfer of myoglobin and its application in biosensing. , 2012, Bioelectrochemistry.

[50]  Tinglin Huang,et al.  Myoglobin immobilized on LaF3 doped CeO2 and ionic liquid composite film for nitrite biosensor , 2012 .