Effects of adsorbed proteins, an antifouling agent and long-duration DC voltage pulses on the impedance of silicon-based neural microelectrodes

The successful use of implantable neural microelectrodes as neuroprosthetic devices depends on the mitigation of the reactive tissue response of the brain. One of the factors affecting the ultimate severity of the reactive tissue response and the in vivo electrical properties of the microelectrodes is the initial adsorption of proteins onto the surface of the implanted microelectrodes. In this study we quantify the increase in microelectrode impedance magnitude at physiological frequencies following electrode immersion in a 10% bovine serum albumin (BSA) solution. We also demonstrate the efficacy of a common antifouling molecule, poly(ethylene glycol) (PEG), in preventing a significant increase in microelectrode impedance. In addition, we show the feasibility of using long-duration DC voltage pulses to remove adsorbed proteins from the microelectrode surface.

[1]  D. Edell,et al.  Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex , 1992, IEEE Transactions on Biomedical Engineering.

[2]  A. Birand,et al.  Left ventricular systolic and diastolic functions in patients with sickle cell anemia , 1998, The International journal of angiology : official publication of the International College of Angiology, Inc.

[3]  Jean-Marc Fellous,et al.  In vitro model of glial scarring around neuroelectrodes chronically implanted in the CNS. , 2006, Biomaterials.

[4]  Daryl R. Kipke,et al.  Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes , 2006, IEEE Transactions on Biomedical Engineering.

[5]  D. Williams,et al.  Protein absorption and desorption phenomena on clean metal surfaces. , 1985, Journal of biomedical materials research.

[6]  Jerald D. Kralik,et al.  Chronic, multisite, multielectrode recordings in macaque monkeys , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[7]  A. Lajtha,et al.  Protein content of various regions of rat brain and adult and aging human brain , 1992, AGE.

[8]  D. Kipke,et al.  Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  David C. Martin,et al.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.

[10]  N Wisniewski,et al.  Characterization of implantable biosensor membrane biofouling , 2000, Fresenius' journal of analytical chemistry.

[11]  Justin C. Williams,et al.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex , 2004, IEEE Transactions on Biomedical Engineering.

[12]  D. Szarowski,et al.  Brain responses to micro-machined silicon devices , 2003, Brain Research.

[13]  C. Babbs,et al.  Intravenous polyethylene glycol inhibits the loss of cerebral cells after brain injury. , 2005, Journal of neurotrauma.

[14]  E. Aydil,et al.  Polyethylene glycol-coated biocompatible surfaces. , 2000, Journal of biomedical materials research.

[15]  Kevin J. Otto,et al.  Thin-film silica sol–gel coatings for neural microelectrodes , 2009, Journal of Neuroscience Methods.

[16]  X Liu,et al.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[17]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[18]  J. Fawcett,et al.  The glial scar and central nervous system repair , 1999, Brain Research Bulletin.