The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizesmore » each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, 'HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment', ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. Table 1 summarizes the energy savings potential of the highest scoring options from the 2005 study for all five locations. All system options were scored by the ORNL building equipment research team and by William Goetzler of Navigant Consulting. These scores were reviewed by DOE/BT's Residential Integration program leaders and Building America team members. Based on these results, the two centrally ducted integrated heat pump (IHP) systems (air source and ground source versions) were selected for advancement to Stage 2 (Exploratory Development) business case assessments in FY06. This report describes results of these business case assessments. It is a compilation of three separate reports describing the initial business case study (Baxter 2006a), an update to evaluate the impact of an economizer cooling option (Baxter 2006b), and a second update to evaluate the impact of a winter humidification option (Baxter 2007). In addition it reports some corrections made subsequent to release of the first two reports to correct some errors in the TRNSYS building model for Atlanta and in the refrigerant pressure drop calculation in the water-to-refrigerant evaporator module of the ORNL Heat Pump Design Model (HPDM) used for the IHP analyses. These changes resulted in some minor differences between IHP performance as reported in Baxter (2006a, b) and in this report.« less
[1]
R. Hendron.
Building America Research Benchmark Definition
,
2008
.
[2]
Van D Baxter.
Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes
,
2006
.
[3]
Van D Baxter,et al.
Integrated Heat Pump (IHP) System Development - Air-Source IHP Control Strategy and Specifications and Ground-Source IHP Conceptual Design
,
2007
.
[4]
Van D Baxter.
Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Update to Include Analyses of an Economizer Option and Alternative Winter Water Heating Control Option
,
2006
.
[5]
Van D Baxter.
HVAC Equipment Design Options for Near-Zero-Energy Homes (NZEH) -A Stage 2 Scoping Assessment
,
2005
.
[6]
R. Judkoff,et al.
Building America Performance Analysis Procedures: Revision 1
,
2004
.
[7]
Standard Ashrae.
Thermal Environmental Conditions for Human Occupancy
,
1992
.
[8]
Lew Harriman,et al.
Humidity Control Design Guide for Commercial and Institutional Buildings
,
2001
.
[9]
Michael J. Witte,et al.
ASHRAE 1254-RP EVALUATING THE ABILITY OF UNITARY EQUIPMENT TO MAINTAIN ADEQUATE SPACE HUMIDITY LEVELS, PHASE II
,
2006
.
[10]
Kendra Tupper,et al.
Analysis of System Strategies Targeting Near- Term Building America Energy-Performance Goals for New Single-Family Homes FY 2004 Fourth-Quarter Building America Milestone Report
,
2004
.
[11]
Robert Hendron,et al.
Building America Research Benchmark Definition: Updated December 2009
,
2008
.
[12]
James E. McMahon,et al.
Technical Support Document: Energy efficiency standards for consumer products: residential central air conditioners and heat pumps
,
2004
.
[13]
Kohta Ueno,et al.
RESIDENTIAL DEHUMIDIFICATION AND VENTILATION SYSTEMS RESEARCH FOR HOT-HUMID CLIMATES
,
2003
.
[14]
Willett Kempton,et al.
Information and Telecommunication Technologies : The Next Generation of Residential DSM and Beyond
,
1996
.
[15]
Van D Baxter.
Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Update to Include Evaluation of Impact of Including a Humidifier Option
,
2007
.