Emerging Trends in Heart Valve Engineering: Part IV. Computational Modeling and Experimental Studies

In this final portion of an extensive review of heart valve engineering, we focus on the computational methods and experimental studies related to heart valves. The discussion begins with a thorough review of computational modeling and the governing equations of fluid and structural interaction. We then move onto multiscale and disease specific modeling. Finally, advanced methods related to in vitro testing of the heart valves are reviewed. This section of the review series is intended to illustrate application of computational methods and experimental studies and their interrelation for studying heart valves.

[1]  Fotis Sotiropoulos,et al.  A numerical method for solving the 3D unsteady incompressible Navier-Stokes equations in curvilinear domains with complex immersed boundaries , 2007, J. Comput. Phys..

[2]  F. Yin,et al.  Biaxial mechanical behavior of excised porcine mitral valve leaflets. , 1995, The American journal of physiology.

[3]  Y. T. Chew,et al.  Particle image velocimetry in the investigation of flow past artificial heart valves , 2006, Annals of Biomedical Engineering.

[4]  Michael S Sacks,et al.  On the biaxial mechanical properties of the layers of the aortic valve leaflet. , 2005, Journal of biomechanical engineering.

[5]  C S Peskin,et al.  Fluid dynamics of the mitral valve: physiological aspects of a mathematical model. , 1982, The American journal of physiology.

[6]  F J Schoen,et al.  Biologic determinants of dystrophic calcification and osteocalcin deposition in glutaraldehyde-preserved porcine aortic valve leaflets implanted subcutaneously in rats. , 1983, The American journal of pathology.

[7]  Alberto Redaelli,et al.  3-D simulation of the SJM bileaflet valve opening process: fluid-structure interaction study and experimental validation , 2004 .

[8]  R. Glowinski,et al.  A new formulation of the distributed Lagrange multiplier/fictitious domain method for particulate flows , 2000 .

[9]  Dhanjoo N. Ghista,et al.  Mitral-valve mechanics—stress/strain characteristics of excised leaflets, analysis of its functional mechanics and its medical application , 1973, Medical and biological engineering.

[10]  Jean Lemay,et al.  Extensive study of temperature dissipation measurements on the centerline of a turbulent round jet based on the $$\overline{\theta^{2}}/2$$θ2¯/2 budget , 2013 .

[11]  Arash Kheradvar,et al.  Proof of concept of FOLDAVALVE, a novel 14 Fr totally repositionable and retrievable transcatheter aortic valve. , 2015, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[12]  Roland Hetzer,et al.  Mitroflow aortic pericardial bioprosthesis--clinical performance. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[13]  Colin Martin Leonardo da Vinci: Experience, Experiment and Design , 2006, BMJ : British Medical Journal.

[14]  H T Low,et al.  Steady flow dynamics of prosthetic aortic heart valves: a comparative evaluation with PIV techniques. , 1998, Journal of biomechanics.

[15]  M. Thubrikar,et al.  Role of mechanical stress in calcification of aortic bioprosthetic valves. , 1983, The Journal of thoracic and cardiovascular surgery.

[16]  Fotis Sotiropoulos,et al.  Flow in a mechanical bileaflet heart valve at laminar and near-peak systole flow rates: CFD simulations and experiments. , 2005, Journal of biomechanical engineering.

[17]  Boyce E. Griffith,et al.  Immersed Boundary Method for Variable Viscosity and Variable Density Problems Using Fast Constant-Coefficient Linear Solvers II: Theory , 2014, SIAM J. Sci. Comput..

[18]  Jeffrey E. Bischoff,et al.  A microstructurally based orthotropic hyperelastic constitutive law , 2002 .

[19]  Eli J. Weinberg,et al.  A Computational Model of Aging and Calcification in the Aortic Heart Valve , 2009, PloS one.

[20]  I Vesely,et al.  Tissue buckling as a mechanism of bioprosthetic valve failure. , 1988, The Annals of thoracic surgery.

[21]  Y. Moriyama,et al.  Congenital bicuspid aortic valve: analysis of 63 surgical cases. , 1998, The Journal of heart valve disease.

[22]  Arash Kheradvar,et al.  High-speed particle image velocimetry to assess cardiac fluid dynamics in vitro: From performance to validation , 2012 .

[23]  Boyce E. Griffith,et al.  An adaptive, formally second order accurate version of the immersed boundary method , 2007, J. Comput. Phys..

[24]  Jia Lu,et al.  Dynamic Simulation of Bioprosthetic Heart Valves Using a Stress Resultant Shell Model , 2008, Annals of Biomedical Engineering.

[25]  Jens-Uwe Voigt,et al.  Left ventricular flow patterns in healthy subjects and patients with prosthetic mitral valves: an in vivo study using echocardiographic particle image velocimetry. , 2010, The Journal of thoracic and cardiovascular surgery.

[26]  F P T Baaijens,et al.  A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve. , 2003, Journal of biomechanics.

[27]  R. P. Cochran,et al.  Stress/Strain Characteristics of Porcine Mitral Valve Tissue: Parallel Versus Perpendicular Collagen Orientation , 1992, Journal of cardiac surgery.

[28]  Neelesh A. Patankar,et al.  A new mathematical formulation and fast algorithm for fully resolved simulation of self-propulsion , 2009, J. Comput. Phys..

[29]  Steven Deutsch,et al.  Wall shear-rate estimation within the 50cc Penn State artificial heart using particle image velocimetry. , 2004, Journal of biomechanical engineering.

[30]  H T Low,et al.  Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage. , 2001, Journal of biomechanics.

[31]  A. Ibrahimbegovic Nonlinear Solid Mechanics , 2009 .

[32]  Alexander Kulik,et al.  Long-Term Clinical and Hemodynamic Performance of the Hancock II Versus the Perimount Aortic Bioprostheses , 2010, Circulation.

[33]  Friedrich-Christian Riess,et al.  The Mosaic porcine bioprosthesis: role of age on clinical performance in aortic position. , 2011, The Journal of thoracic and cardiovascular surgery.

[34]  Susan Armstrong,et al.  Hancock II bioprosthesis for aortic valve replacement: the gold standard of bioprosthetic valves durability? , 2010, The Annals of thoracic surgery.

[35]  C. Peskin,et al.  Simulation of a Flapping Flexible Filament in a Flowing Soap Film by the Immersed Boundary Method , 2002 .

[36]  J. G. García Páez,et al.  Tissue heart valve mineralization: Review of calcification mechanisms and strategies for prevention. , 2008, Journal of applied biomaterials & biomechanics : JABB.

[37]  Lorenzo Scalise,et al.  PIV Measurements of Flows in Artificial Heart Valves , 2007 .

[38]  G. Thurston,et al.  Rheological parameters for the viscosity viscoelasticity and thixotropy of blood. , 1979, Biorheology.

[39]  Arash Kheradvar,et al.  Load-dependent extracellular matrix organization in atrioventricular heart valves: differences and similarities. , 2015, American journal of physiology. Heart and circulatory physiology.

[40]  J D Janssen,et al.  A mechanical analysis of the closed Hancock heart valve prosthesis. , 1988, Journal of biomechanics.

[41]  B. Bellhouse,et al.  Fluid Mechanics of the Mitral Valve , 1969, Nature.

[42]  C. Willert,et al.  Digital particle image velocimetry , 1991 .

[43]  Stuart Lipsitz,et al.  Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients. , 2010, The Annals of thoracic surgery.

[44]  Ellen K. Longmire,et al.  Volumetric velocity measurements on flows through heart valves , 2009 .

[45]  H Harasaki,et al.  Biomaterial-associated calcification: pathology, mechanisms, and strategies for prevention. , 1988, Journal of biomedical materials research.

[46]  Boyce E. Griffith,et al.  Quasi-static image-based immersed boundary-finite element model of left ventricle under diastolic loading , 2014, International journal for numerical methods in biomedical engineering.

[47]  Mahsa Dabagh,et al.  Effects of polydimethylsiloxane grafting on the calcification, physical properties, and biocompatibility of polyurethane in a heart valve , 2005 .

[48]  E. Weinberg,et al.  A multiscale computational comparison of the bicuspid and tricuspid aortic valves in relation to calcific aortic stenosis. , 2008, Journal of biomechanics.

[49]  J. Halleux,et al.  An arbitrary lagrangian-eulerian finite element method for transient dynamic fluid-structure interactions , 1982 .

[50]  K Affeld,et al.  The use of image processing in the investigation of artificial heart valve flow. , 1989, ASAIO transactions.

[51]  X. Luo,et al.  A nonlinear anisotropic model for porcine aortic heart valves. , 2001, Journal of biomechanics.

[52]  James Lighthill Physiological fluid mechanics , 1971 .

[53]  Eli J Weinberg,et al.  A large-strain finite element formulation for biological tissues with application to mitral valve leaflet tissue mechanics. , 2006, Journal of biomechanics.

[54]  G. G. Peters,et al.  A two-dimensional fluid–structure interaction model of the aortic value , 2000 .

[55]  R. Cheng,et al.  Three-Dimensional Fluid-Structure Interaction Simulation of Bileaflet Mechanical Heart Valve Flow Dynamics , 2004, Annals of Biomedical Engineering.

[56]  Zhaosheng Yu A DLM/FD method for fluid/flexible-body interactions , 2005 .

[57]  Steven Deutsch,et al.  Results of FDA’s First Interlaboratory Computational Study of a Nozzle with a Sudden Contraction and Conical Diffuser , 2013 .

[58]  Yongsam Kim,et al.  On various techniques for computer simulation of boundaries with mass , 2003 .

[59]  Nikolay V. Vasilyev,et al.  In Vitro Characterization of Bicuspid Aortic Valve Hemodynamics Using Particle Image Velocimetry , 2012, Annals of Biomedical Engineering.

[60]  Charles S. Peskin,et al.  Modeling prosthetic heart valves for numerical analysis of blood flow in the heart , 1980 .

[61]  C. Peskin,et al.  Mechanical equilibrium determines the fractal fiber architecture of aortic heart valve leaflets. , 1994, The American journal of physiology.

[62]  K B Chandran,et al.  Effect of wedging on the flow characteristics past tilting disc aortic valve prosthesis. , 1986, Journal of biomechanics.

[63]  Eli J. Weinberg,et al.  Hemodynamic Environments from Opposing Sides of Human Aortic Valve Leaflets Evoke Distinct Endothelial Phenotypes In Vitro , 2010, Cardiovascular engineering.

[64]  Wing Kam Liu,et al.  Nonlinear Finite Elements for Continua and Structures , 2000 .

[65]  L. Heltai,et al.  On the hyper-elastic formulation of the immersed boundary method , 2008 .

[66]  Hwa Liang Leo,et al.  Fluid Dynamic Assessment of Three Polymeric Heart Valves Using Particle Image Velocimetry , 2006, Annals of Biomedical Engineering.

[67]  D. Mavrilas,et al.  Development of bioprosthetic heart valve calcification in vitro and in animal models: morphology and composition , 1999 .

[68]  Yos S. Morsi,et al.  Transient fluid–structure coupling for simulation of a trileaflet heart valve using weak coupling , 2007, Journal of Artificial Organs.

[69]  Umberto Morbiducci,et al.  Innovative technologies for the assessment of cardiovascular medical devices: state-of-the-art techniques for artificial heart valve testing , 2004, Expert review of medical devices.

[70]  W R Jamieson,et al.  Carpentier-Edwards standard porcine bioprosthesis: a 21-year experience. , 1998, The Annals of thoracic surgery.

[71]  Ulrich Steinseifer,et al.  A low-volume tester for the thrombogenic potential of mechanical heart valve prostheses. , 2011, The Journal of heart valve disease.

[72]  M. Gharib,et al.  Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. , 2000, Journal of biomechanical engineering.

[73]  D. J. Wheatley,et al.  A dynamicin vitro method for studying bioprosthetic heart valve calcification , 1992 .

[74]  F P T Baaijens,et al.  A three-dimensional computational analysis of fluid-structure interaction in the aortic valve. , 2003, Journal of biomechanics.

[75]  A. Azadani,et al.  Comparison of mechanical properties of human ascending aorta and aortic sinuses. , 2012, The Annals of thoracic surgery.

[76]  Arash Kheradvar,et al.  Three-dimensional reconstruction of cardiac flows based on multi-planar velocity fields , 2014 .

[77]  Carl F. Popelar,et al.  In Vitro Testing of Heart Valve Substitutes , 2013 .

[78]  Boyce E. Griffith,et al.  Simulating the fluid dynamics of natural and prosthetic heart valves using the immersed boundary method , 2009 .

[79]  Georgios C. Georgiou,et al.  The influence of temperature on rheological properties of blood mixtures with different volume expanders—implications in numerical arterial hemodynamics simulations , 2011 .

[80]  F J Schoen,et al.  Calcification of bioprosthetic heart valves: a perspective on models. , 1992, The Journal of heart valve disease.

[81]  F. Baaijens,et al.  A synthetic fiber-reinforced stentless heart valve. , 2000, Journal of biomechanics.

[82]  Eli J Weinberg,et al.  A finite shell element for heart mitral valve leaflet mechanics, with large deformations and 3D constitutive material model. , 2007, Journal of biomechanics.

[83]  S. Deutsch,et al.  Integrating particle image velocimetry and laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves. , 2001, Artificial organs.

[84]  Arash Kheradvar,et al.  The Effects of Positioning of Transcatheter Aortic Valves on Fluid Dynamics of the Aortic Root , 2014, ASAIO journal.

[85]  D. Mavrilas,et al.  Screening biomaterials with a new in vitro method for potential calcification: Porcine aortic valves and bovine pericardium , 2004, Journal of materials science. Materials in medicine.

[86]  Petros Koutsoukos,et al.  In Vivo Calcification of Glutaraldehyde-Fixed Cardiac Valve and Pericardium of Phoca groenlandica , 2011, ASAIO journal.

[87]  Boyce E. Griffith,et al.  A finite strain nonlinear human mitral valve model with fluid-structure interaction , 2014, International journal for numerical methods in biomedical engineering.

[88]  Arash Kheradvar,et al.  An In Vitro Study of Changing Profile Heights in Mitral Bioprostheses and Their Influence on Flow , 2006, ASAIO journal.

[89]  G. Christie,et al.  Tears in bioprosthetic heart valve leaflets without calcific degeneration. , 1996, The Journal of heart valve disease.

[90]  J M Gross,et al.  Calcification of bioprosthetic heart valves and its assessment. , 2001, The Journal of thoracic and cardiovascular surgery.

[91]  Lorenzo Scalise,et al.  Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve. , 2004, Artificial organs.

[92]  Jacques M Huyghe,et al.  Computational analyses of mechanically induced collagen fiber remodeling in the aortic heart valve. , 2003, Journal of biomechanical engineering.

[93]  Boyce E. Griffith,et al.  Immersed Boundary Method for Variable Viscosity and Variable Density Problems Using Fast Constant-Coefficient Linear Solvers I: Numerical Method and Results , 2013, SIAM J. Sci. Comput..

[94]  M. Sacks,et al.  Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II--A structural constitutive model. , 2000, Journal of biomechanical engineering.

[95]  Boyce E. Griffith,et al.  Immersed boundary model of aortic heart valve dynamics with physiological driving and loading conditions , 2012, International journal for numerical methods in biomedical engineering.

[96]  G Thiene,et al.  Ultrastructural substrates of dystrophic calcification in porcine bioprosthetic valve failure. , 1985, The American journal of pathology.

[97]  P E Oyer,et al.  Durability of porcine valves at fifteen years in a representative North American patient population. , 1992, The Journal of thoracic and cardiovascular surgery.

[98]  Birgit Glasmacher,et al.  In vitro pH‐controlled calcification of biological heart valve prostheses , 2006 .

[99]  Umberto Morbiducci,et al.  Critical aspects for a CFD simulation compared with PIV analysis of the flow field downstream a prosthetic heart valve , 2003 .

[100]  Frederick J Schoen,et al.  Calcification of tissue heart valve substitutes: progress toward understanding and prevention. , 2005, The Annals of thoracic surgery.

[101]  Arash Kheradvar,et al.  The effects of dynamic saddle annulus and leaflet length on transmitral flow pattern and leaflet stress of a bileaflet bioprosthetic mitral valve. , 2012, The Journal of heart valve disease.

[102]  M. Wernet Digital Particle Image Velocimetry , 2003 .

[103]  Fotis Sotiropoulos,et al.  Characterization of Hemodynamic Forces Induced by Mechanical Heart Valves: Reynolds vs. Viscous Stresses , 2008, Annals of Biomedical Engineering.

[104]  C. Peskin Flow patterns around heart valves: A numerical method , 1972 .

[105]  L. Lourenço Particle Image Velocimetry , 1989 .

[106]  Ajit P Yoganathan,et al.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices. , 2015, Journal of biomechanical engineering.

[107]  R. Ogden Non-Linear Elastic Deformations , 1984 .

[108]  R Shandas,et al.  Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: in vitro steady. , 1996, Biomedical sciences instrumentation.

[109]  Steven Deutsch,et al.  Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry. , 2003, Artificial organs.

[110]  I Vesely,et al.  Analysis of the bending behaviour of porcine xenograft leaflets and of natural aortic valve material: bending stiffness, neutral axis and shear measurements. , 1989, Journal of biomechanics.

[111]  M. Sacks,et al.  Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: Experimental results. , 2000, Journal of biomechanical engineering.

[112]  Vittoria Flamini,et al.  Simulating the Dynamics of an Aortic Valve Prosthesis in a Pulse Duplicator: Numerical Methods and Initial Experience. , 2013, Journal of medical devices.

[113]  Hamid Nayeb-Hashemi,et al.  Effects of fluid flow shear rate and surface roughness on the calcification of polymeric heart valve leaflet. , 2013, Materials science & engineering. C, Materials for biological applications.

[114]  Roger D. Kamm,et al.  Cellular mechanotransduction : diverse perspectives from molecules to tissues , 2009 .

[115]  Steven Deutsch,et al.  Assessment of CFD Performance in Simulations of an Idealized Medical Device: Results of FDA’s First Computational Interlaboratory Study , 2012 .

[116]  J. Humphrey,et al.  On constitutive relations and finite deformations of passive cardiac tissue: I. A pseudostrain-energy function. , 1987, Journal of biomechanical engineering.

[117]  van de Fn Frans Vosse,et al.  Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valves , 2004 .

[118]  R. Glowinski,et al.  A distributed Lagrange multiplier/fictitious domain method for particulate flows , 1999 .

[119]  B Glasmacher,et al.  Dynamic in vitro calcification of bioprosthetic porcine valves: evidence of apatite crystallization. , 2001, The Journal of thoracic and cardiovascular surgery.

[120]  Martin Misfeld,et al.  Heart valve macro- and microstructure , 2007, Philosophical Transactions of the Royal Society B: Biological Sciences.

[121]  C. Peskin,et al.  Implicit second-order immersed boundary methods with boundary mass , 2008 .

[122]  L. Scalise,et al.  Time-Resolved PIV Technique for High Temporal Resolution Measurement of Mechanical Prosthetic Aortic Valve Fluid Dynamics , 2007 .

[123]  A. A. van Steenhoven,et al.  An experimental set-up for the in-vitro analysis of polyurethane calcification , 1987 .

[124]  Olga Pierrakos,et al.  Time-resolved DPIV analysis of vortex dynamics in a left ventricular model through bileaflet mechanical and porcine heart valve prostheses. , 2004, Journal of biomechanical engineering.

[125]  C. Peskin Numerical analysis of blood flow in the heart , 1977 .

[126]  F. Yin,et al.  A constitutive law for mitral valve tissue. , 1998, Journal of biomechanical engineering.

[127]  D. Mavrilas,et al.  Model experimental system for investigation of heart valve calcification in vitro. , 1997, Journal of biomedical materials research.

[128]  Boyce E. Griffith,et al.  Image-based fluid-structure interaction model of the human mitral valve , 2013 .

[129]  C. Peskin The immersed boundary method , 2002, Acta Numerica.

[130]  Vittoria Flamini,et al.  Immersed boundary-finite element model of fluid–structure interaction in the aortic root , 2015, Theoretical and computational fluid dynamics.

[131]  P E Oyer,et al.  Twenty-year clinical experience with porcine bioprostheses. , 1996, The Annals of thoracic surgery.

[132]  F J Schoen,et al.  Inhibition of bioprosthetic heart valve calcification with aminodiphosphonate covalently bound to residual aldehyde groups. , 1988, The Annals of thoracic surgery.

[133]  R. Ogden,et al.  Mechanics of biological tissue , 2006 .

[134]  Peter Kremer,et al.  Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years. , 2010, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[135]  I Vesely,et al.  In vivo and in vitro models of calcification in porcine aortic valve cusps. , 1997, The Journal of heart valve disease.

[136]  Hélène A. Simon,et al.  Vorticity dynamics of a bileaflet mechanical heart valve in an axisymmetric aorta , 2007 .

[137]  Eli J Weinberg,et al.  Transient, Three-dimensional, Multiscale Simulations of the Human Aortic Valve , 2007, Cardiovascular engineering.

[138]  C. Liang,et al.  Effect of bending rigidity in a dynamic model of a polyurethane prosthetic mitral valve , 2012, Biomechanics and modeling in mechanobiology.

[139]  Elliot L. Botvinick,et al.  Characterizing the Collagen Fiber Orientation in Pericardial Leaflets Under Mechanical Loading Conditions , 2012, Annals of Biomedical Engineering.

[140]  Danny Bluestein,et al.  Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. , 2007, Artificial organs.

[141]  Umberto Morbiducci,et al.  Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach. , 2008, Journal of biomechanics.

[142]  Danny Bluestein,et al.  Flow-Induced Platelet Activation in Bileaflet and Monoleaflet Mechanical Heart Valves , 2004, Annals of Biomedical Engineering.

[143]  H. Othmer,et al.  Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology , 1997 .

[144]  M. Sacks,et al.  Simulated bioprosthetic heart valve deformation under quasi-static loading. , 2005, Journal of biomechanical engineering.

[145]  Michael S. Sacks,et al.  Orthotropic Mechanical Properties of Chemically Treated Bovine Pericardium , 1998, Annals of Biomedical Engineering.

[146]  R. Glowinski,et al.  Validation of a 3D computational fluid-structure interaction model simulating flow through an elastic aperture. , 2012, Journal of biomechanics.

[147]  Michele Milano,et al.  Correlation Between Vortex Ring Formation and Mitral Annulus Dynamics During Ventricular Rapid Filling , 2007, ASAIO journal.

[148]  Alberto Redaelli,et al.  3-D simulation of the St. Jude Medical bileaflet valve opening process: fluid-structure interaction study and experimental validation. , 2004, The Journal of heart valve disease.

[149]  G F Tyers,et al.  Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural valve deterioration) by age groups. , 1988, The Annals of thoracic surgery.

[150]  Boyce E. Griffith,et al.  Parallel and Adaptive Simulation of Cardiac Fluid Dynamics , 2009 .

[151]  Santanu Chandra,et al.  Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease , 2012, Biomechanics and modeling in mechanobiology.

[152]  Helen Fox Krause In vitro testing: Editor: Ivor A. Emanuel Thieme Medical Publishers, Inc., New York, 1994 , 1996 .

[153]  P. Arratia,et al.  Rheology of human blood plasma: viscoelastic versus Newtonian behavior. , 2013, Physical review letters.

[154]  F. Yin,et al.  A hyperelastic constitutive law for aortic valve tissue. , 2009, Journal of biomechanical engineering.

[155]  Jia Lu,et al.  An Experimentally Derived Stress Resultant Shell Model for Heart Valve Dynamic Simulations , 2006, Annals of Biomedical Engineering.

[156]  O. Higa,et al.  Natural and prosthetic heart valve calcification: morphology and chemical composition characterization. , 2010, Artificial organs.

[157]  Carlos Alberto Brebbia,et al.  Simulations in biomedicine IV , 1997 .

[158]  W S Pierce,et al.  Pierce-Donachy pediatric VAD: progress in development. , 1996, The Annals of thoracic surgery.

[159]  Christoph Brücker Dual-camera DPIV for flow studies past artificial heart valves , 1997 .

[160]  C S Peskin,et al.  Computer-assisted design of butterfly bileaflet valves for the mitral position. , 1985, Scandinavian journal of thoracic and cardiovascular surgery.

[161]  Mehrdad Mehrbod,et al.  Mechanotransduction pathways linking the extracellular matrix to the nucleus. , 2014, International review of cell and molecular biology.

[162]  M. Sacks,et al.  A method for planar biaxial mechanical testing that includes in-plane shear. , 1999, Journal of biomechanical engineering.

[163]  Eli J. Weinberg,et al.  On the Constitutive Models for Heart Valve Leaflet Mechanics , 2005 .

[164]  F. Pinho,et al.  Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system. , 2013, Biomicrofluidics.

[165]  Yongsam Kim,et al.  Penalty immersed boundary method for an elastic boundary with mass , 2007 .

[166]  Francisco Pereira,et al.  Defocusing digital particle image velocimetry: a 3-component 3-dimensional DPIV measurement technique. Application to bubbly flows , 2000 .

[167]  Torsten Doenst,et al.  Durability of tissue valves: Only time will tell? , 2017, The Journal of thoracic and cardiovascular surgery.

[168]  Mario Castaño,et al.  Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[169]  F. Baaijens,et al.  Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole. , 2004, Journal of biomechanics.

[170]  Marcel C. M. Rutten,et al.  Tissue Engineering of Human Heart Valve Leaflets: A Novel Bioreactor for a Strain-Based Conditioning Approach , 2005, Annals of Biomedical Engineering.

[171]  R. D. Wood,et al.  Nonlinear Continuum Mechanics for Finite Element Analysis , 1997 .

[172]  Danny Bluestein,et al.  FLOW INDUCED PLATELET ACTIVATION IN BILEAFLET AND MONOLEAFLET MECHANICAL HEART VALVES , 2004 .