Physical Collection Efficiency of Filter Materials for Bacteria and Viruses

Abstract The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10–900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button™ Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10–600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-μm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.

[1]  P Belgrader,et al.  Rapid pathogen detection using a microchip PCR array instrument. , 1998, Clinical chemistry.

[2]  M. Sobsey,et al.  Reduction of Norwalk Virus, Poliovirus 1, and Bacteriophage MS2 by Ozone Disinfection of Water , 2003, Applied and Environmental Microbiology.

[3]  E. King,et al.  Air Sampling Instruments , 1969 .

[4]  American Conference Of Governmental Industrial Hygienists 1998 Ventilation A O , 2019 .

[5]  W. Fiers Studies on the bacteriophage MS2: III. Sedimentation heterogeneity of viral RNA preparations , 1967 .

[6]  Klaus Willeke,et al.  Aerosol Measurement: Principles, Techniques, and Applications , 2001 .

[7]  Tiina Reponen,et al.  COLLECTION OF FUNGAL SPORES ON AIR FILTERS AND SPORE REENTRAINMENT FROM FILTERS INTO AIR , 2000 .

[8]  S. Johnston,et al.  Airborne rhinovirus detection and effect of ultraviolet irradiation on detection by a semi-nested RT-PCR assay , 2003, BMC public health.

[9]  T. Reponen,et al.  Relationship between indoor and outdoor bio-aerosols collected with a button inhalable aerosol sampler in urban homes. , 2006, Indoor air.

[10]  John E. Bennett,et al.  Principles and practice of infectious diseases. Vols 1 and 2. , 1979 .

[11]  C. Tseng,et al.  Collection efficiencies of aerosol samplers for virus-containing aerosols , 2005, Journal of Aerosol Science.

[12]  H. Jaschhof Sampling Virus Aerosols Using the Gelatin Membrane Filter , 2004 .

[13]  K Willeke,et al.  Performance characteristics of the button personal inhalable aerosol sampler. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[14]  S. Paton,et al.  Detection of Airborne Severe Acute Respiratory Syndrome (SARS) Coronavirus and Environmental Contamination in SARS Outbreak Units , 2005, The Journal of infectious diseases.

[15]  John E. Bennett,et al.  Principles and practices of infectious diseases , 1979 .

[16]  L. Wallace,et al.  Continuous weeklong measurements of personal exposures and indoor concentrations of fine particles for 37 health-impaired North Carolina residents for up to four seasons , 2006 .

[17]  G. Oberdörster,et al.  Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles , 2005, Environmental health perspectives.

[18]  M. E. Alvarez,et al.  Inactivation of MS-2 phage and poliovirus in groundwater. , 2000, Canadian journal of microbiology.

[19]  John A. Miller,et al.  Field guide for the determination of biological contaminants in environmental samples , 1996 .

[20]  L. Liljas,et al.  The refined structure of bacteriophage MS2 at 2.8 A resolution. , 1993, Journal of molecular biology.

[21]  B. V. Bronk,et al.  Detection of Molecular Diversity in Bacillus atrophaeus by Amplified Fragment Length Polymorphism Analysis , 2004, Applied and Environmental Microbiology.

[22]  I. Agranovski,et al.  New personal sampler for viable airborne viruses: feasibility study , 2003 .

[23]  Tiina Reponen,et al.  Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks? , 2006, American journal of infection control.

[24]  T. Reponen,et al.  Effect of sampling time and air humidity on the bioefficiency of filter samplers for bioaerosol collection , 2001 .

[25]  B.Y.H. Liu,et al.  Aerosols in the mining and industrial work environments. Vols 1,2, and 3 , 1983 .

[26]  T. Reponen,et al.  Relationship between indoor and outdoor airborne fungal spores, pollen, and (1→3)-β-D-glucan in homes without visible mold growth , 2006 .

[27]  James J. Valdes,et al.  Real-Time Fluorogenic Reverse Transcription-PCR Assays for Detection of Bacteriophage MS2 , 2006, Applied and Environmental Microbiology.

[28]  I. Agranovski,et al.  Inactivation of Viruses in Bubbling Processes Utilized for Personal Bioaerosol Monitoring , 2004, Applied and Environmental Microbiology.

[29]  Pratim Biswas,et al.  Capture of Viral Particles in Soft X-Ray–Enhanced Corona Systems: Charge Distribution and Transport Characteristics , 2004 .

[30]  Lars Liljas,et al.  The three-dimensional structure of the bacterial virus MS2 , 1990, Nature.

[31]  C. Tseng,et al.  Inactivation of Virus-Containing Aerosols by Ultraviolet Germicidal Irradiation , 2005 .

[32]  W. Heineman,et al.  Bead-based electrochemical immunoassay for bacteriophage MS2. , 2004, Analytical chemistry.

[33]  A. Mills,et al.  Manual of environmental microbiology. , 2007 .

[34]  K. Carroll,et al.  Comparison of membrane filters for recovery of legionellae from water samples , 1993, Applied and environmental microbiology.

[35]  Tiina Reponen,et al.  The effect of filter material on bioaerosol collection of Bacillus subtilis spores used as a Bacillus anthracis simulant. , 2005, Journal of environmental monitoring : JEM.