Combined system of fluorescence diffuse optical tomography and microcomputed tomography for small animal imaging.

We developed a dual-modality system that combines fluorescence diffuse optical tomography (fDOT) and flat panel detector-based microcomputed tomography (micro-CT) to simultaneously reveal molecular and structural information in small animals. In fDOT, a 748 nm diode laser was used as an excitation source, while a cooled charge coupled device camera was adopted to collect transmission fluorescence. In micro-CT, a flat panel detector based on amorphous silicon, with active area of 13 x 13 cm(2), and a microfocus x-ray tube were used. The fDOT system was mounted orthogonally to the micro-CT and the projection images were acquired without rotation of the sample, which is different from the method used for micro-CT alone. Both the finite element method and the algebraic reconstruction technique were used to reconstruct images from the fDOT. Phantom data showed that the resolution of the fDOT system was about 3 mm at an imaging depth of 7 mm. Quantitative error was no more than 5% and imaging sensitivity for 1,1(')-dioctadecyl-3,3,3('),3(')-etramethylindotricarbocyanine iodide bis-oleate (DiR-BOA) was estimated to be higher than 100 nM at a depth of 7 mm. Calculations of the phantom's center of mass showed that the location accuracy of fDOT was about 0.7 mm. We applied a Feldkamp algorithm to reconstruct the micro-CT image. By measuring the presampled modulation transfer function with a 30 microm tungsten thread, we estimated that the micro-CT has a resolution of 5 mm(-1) when the field of view was 6.5 cm. Our results indicate the uniformity of the transaxial micro-CT image and the contrast-to-noise ratio was measured as 1.95 for a radiation dose of 1 cGy. A non-image-based method was employed for merging images from the two imaging modalities. A nude mouse with DiR-BOA, imaged ex vivo, was used to validate the feasibility of the dual-modality system.

[1]  Vasilis Ntziachristos,et al.  Optimization of 360° projection fluorescence molecular tomography , 2007, Medical Image Anal..

[2]  S R Arridge,et al.  Recent advances in diffuse optical imaging , 2005, Physics in medicine and biology.

[3]  Andrew K. Dunn,et al.  A Time Domain Fluorescence Tomography System for Small Animal Imaging , 2008, IEEE Transactions on Medical Imaging.

[4]  Q. Luo,et al.  Overcoming ill-posedness of diffuse optical tomography in steady-state domain , 2008 .

[5]  M. Eppstein,et al.  Three-dimensional fluorescence lifetime tomography. , 2005, Medical physics.

[6]  J. Boone,et al.  Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner. , 2006, Medical physics.

[7]  Jean-Marc Dinten,et al.  Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination. , 2009, Applied optics.

[8]  Stephen B. Tuttle,et al.  Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue. , 2008, The Review of scientific instruments.

[9]  Jan Sijbers,et al.  Reduction of ring artefacts in high resolution micro-CT reconstructions. , 2004, Physics in medicine and biology.

[10]  Patrick L Chow,et al.  A method of image registration for small animal, multi-modality imaging , 2006, Physics in medicine and biology.

[11]  Gultekin Gulsen,et al.  Quantitative fluorescence tomography with functional and structural a priori information. , 2009, Applied optics.

[12]  Alberto Del Guerra,et al.  State-of-the-art of PET, SPECT and CT for small animal imaging , 2007 .

[13]  Qingming Luo,et al.  Biomimetic nanocarrier for direct cytosolic drug delivery. , 2009, Angewandte Chemie.

[14]  Hamid Dehghani,et al.  A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging. , 2009, The Review of scientific instruments.

[15]  O Nalcioglu,et al.  Combined Fluorescence and X-Ray Tomography for Quantitative In Vivo Detection of Fluorophore , 2010, Technology in cancer research & treatment.

[16]  Harvey R Herschman,et al.  Molecular Imaging: Looking at Problems, Seeing Solutions , 2003, Science.

[17]  S. Gambhir,et al.  Molecular imaging in living subjects: seeing fundamental biological processes in a new light. , 2003, Genes & development.

[18]  B. Pogue,et al.  Image-guided diffuse optical fluorescence tomography implemented with Laplacian-type regularization. , 2007, Optics express.

[19]  D. Townsend Multimodality imaging of structure and function , 2008, Physics in medicine and biology.

[20]  Rinaldo Cubeddu,et al.  Comparison of noncontact and fiber-based fluorescence-mediated tomography. , 2006, Optics letters.

[21]  Kai Yang,et al.  A geometric calibration method for cone beam CT systems. , 2006, Medical physics.

[22]  Vasilis Ntziachristos,et al.  Hybrid System for Simultaneous Fluorescence and X-Ray Computed Tomography , 2010, IEEE Transactions on Medical Imaging.

[23]  Shaoqun Zeng,et al.  A LabVIEW driver for X-ray flat-panel detector , 2008 .

[24]  R. Weissleder,et al.  Imaging in the era of molecular oncology , 2008, Nature.

[25]  Vasilis Ntziachristos,et al.  A submillimeter resolution fluorescence molecular imaging system for small animal imaging. , 2003, Medical physics.

[26]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[27]  R. Weissleder,et al.  Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation. , 2001, Optics letters.

[28]  R. Weissleder,et al.  Molecular imaging in drug discovery and development , 2003, Nature Reviews Drug Discovery.

[29]  D. Jaffray,et al.  A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager. , 1999, Medical physics.

[30]  Wolfhard Semmler,et al.  Intrinsic respiratory gating in small-animal CT , 2008, European Radiology.

[31]  Eric L. Miller,et al.  Hybrid FMT–CT imaging of amyloid-β plaques in a murine Alzheimer's disease model , 2009, NeuroImage.

[32]  Anne Koenig,et al.  In vivo mice lung tumor follow-up with fluorescence diffuse optical tomography. , 2008, Journal of biomedical optics.

[33]  J.-M. Dinten,et al.  Whole body in vivo examination of small animals by simultaneous X-rays/optical tomography: comparison between the reconstructions obtained with different types of fluorescent labels , 2007, European Conference on Biomedical Optics.

[34]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[35]  Vasilis Ntziachristos,et al.  Fluorescence molecular-tomography reconstruction with a priori anatomical information , 2008, SPIE BiOS.

[36]  M. Desco,et al.  Assessment of a New High-Performance Small-Animal X-Ray Tomograph , 2008, IEEE Transactions on Nuclear Science.

[37]  R. Street,et al.  A comparison of x-ray detectors for mouse CT imaging , 2004, Physics in medicine and biology.

[38]  Vasilis Ntziachristos,et al.  Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography on the optical forward problem. , 2009, Journal of the Optical Society of America. A, Optics, image science, and vision.

[39]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[40]  Yuting Lin,et al.  Fluorescence diffuse optical tomography with functional and anatomical a priori information: feasibility study , 2007, Physics in medicine and biology.

[41]  M J Paulus,et al.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research. , 2000, Neoplasia.

[42]  T. MacVittie,et al.  Postirradiation treatment with granulocyte colony-stimulating factor and preirradiation WR-2721 administration synergize to enhance hemopoietic reconstitution and increase survival. , 1992, International journal of radiation oncology, biology, physics.

[43]  E. Samei,et al.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device. , 1998, Medical physics.

[44]  Vasilis Ntziachristos,et al.  Free-space fluorescence molecular tomography utilizing 360° geometry projections , 2007 .

[45]  I. G. Meerovich,et al.  Fluorescence diffuse tomography for detection of red fluorescent protein expressed tumors in small animals. , 2008, Journal of biomedical optics.

[46]  Lingyun Chen,et al.  Spatial resolution properties in cone beam CT: a simulation study. , 2008, Medical physics.