Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring.

PURPOSE To develop and validate an informatics toolkit that extracts anatomy-specific computed tomography (CT) radiation exposure metrics (volume CT dose index and dose-length product) from existing digital image archives through optical character recognition of CT dose report screen captures (dose screens) combined with Digital Imaging and Communications in Medicine attributes. MATERIALS AND METHODS This institutional review board-approved HIPAA-compliant study was performed in a large urban health care delivery network. Data were drawn from a random sample of CT encounters that occurred between 2000 and 2010; images from these encounters were contained within the enterprise image archive, which encompassed images obtained at an adult academic tertiary referral hospital and its affiliated sites, including a cancer center, a community hospital, and outpatient imaging centers, as well as images imported from other facilities. Software was validated by using 150 randomly selected encounters for each major CT scanner manufacturer, with outcome measures of dose screen retrieval rate (proportion of correctly located dose screens) and anatomic assignment precision (proportion of extracted exposure data with correctly assigned anatomic region, such as head, chest, or abdomen and pelvis). The 95% binomial confidence intervals (CIs) were calculated for discrete proportions, and CIs were derived from the standard error of the mean for continuous variables. After validation, the informatics toolkit was used to populate an exposure repository from a cohort of 54 549 CT encounters; of which 29 948 had available dose screens. RESULTS Validation yielded a dose screen retrieval rate of 99% (597 of 605 CT encounters; 95% CI: 98%, 100%) and an anatomic assignment precision of 94% (summed DLP fraction correct 563 in 600 CT encounters; 95% CI: 92%, 96%). Patient safety applications of the resulting data repository include benchmarking between institutions, CT protocol quality control and optimization, and cumulative patient- and anatomy-specific radiation exposure monitoring. CONCLUSION Large-scale anatomy-specific radiation exposure data repositories can be created with high fidelity from existing digital image archives by using open-source informatics tools.

[1]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[2]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[3]  Michael J Pentecost,et al.  American College of Radiology white paper on radiation dose in medicine. , 2007, Journal of the American College of Radiology : JACR.

[4]  David A Clunie,et al.  DICOM Structured Reporting and Cancer Clinical Trials Results , 2007, Cancer informatics.

[5]  C J Martin,et al.  Effective dose: how should it be applied to medical exposures? , 2007, The British journal of radiology.

[6]  W. Huda,et al.  Effective doses in radiology and diagnostic nuclear medicine: a catalog. , 2008, Radiology.

[7]  T. Yoshizumi,et al.  Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources--1950-2007. , 2009, Radiology.

[8]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[9]  Harlan M Krumholz,et al.  Exposure to low-dose ionizing radiation from medical imaging procedures. , 2009, The New England journal of medicine.

[10]  A. Sodickson,et al.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. , 2009, Radiology.

[11]  William W. Boonn,et al.  Automated extraction of radiation dose information for CT examinations. , 2010, Journal of the American College of Radiology : JACR.

[12]  A. Sodickson,et al.  Patient-centric radiation dose monitoring in the electronic health record: what are some of the barriers and key next steps? , 2010, Journal of the American College of Radiology : JACR.

[13]  C. McCollough,et al.  How effective is effective dose as a predictor of radiation risk? , 2010, AJR. American journal of roentgenology.

[14]  Considerations and preliminary design of patient exposure registry. , 2010, Radiation protection dosimetry.

[15]  Rebecca S Lewis,et al.  Projected cancer risks from computed tomographic scans performed in the United States in 2007. , 2009, Archives of internal medicine.

[16]  J. Boone,et al.  CT dose index and patient dose: they are not the same thing. , 2011, Radiology.

[17]  R. Zabih,et al.  Automated framework for digital radiation dose index reporting from CT dose reports. , 2011, AJR. American journal of roentgenology.

[18]  Cynthia H McCollough,et al.  The feasibility of patient size-corrected, scanner-independent organ dose estimates for abdominal CT exams. , 2011, Medical physics.

[19]  Richard L Morin,et al.  ACR Dose Index Registry. , 2011, Journal of the American College of Radiology : JACR.

[20]  Andrew D. A. Maidment,et al.  RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.