Performance of non-contact infrared thermometer for detecting febrile children in hospital and ambulatory settings.

AIMS To assess the performance of the non-contact infrared thermometer compared with mercury-in-glass thermometer in children; to assess the diagnostic accuracy of non-contact infrared thermometer for detecting children with fever; to compare the discomfort caused by the two procedures in children aged > one month. BACKGROUND Non-contact infrared thermometer is a quick and non-invasive method to measure body temperature, not requiring sterilisation or disposables. It is a candidate for temperature recording in children. DESIGN Prospective multicenter study. METHODS Body temperature readings were taken from every child consecutively admitted to the Pediatric Emergency Departments or Pediatric Clinics participating in the study. Two bilateral axillary temperature measurements using the mercury-in-glass thermometers and three mid-forehead temperature measurements using the non-contact infrared thermometer were performed. RESULTS Two hundred and fifty-one children were enrolled in the study. Mean body temperature obtained by mercury-in-glass thermometer and non-contact infrared thermometer was 37.18 (SD 0.96) °C and 37.30 (SD 0.92) °C, respectively (p = 0.153). Non-contact infrared thermometer clinical repeatability was 0.108 (SD 0.095) °C, similar to that of the mercury-in-glass thermometer (0.11 SD 01 °C; p = 0.517). Bias was 0.0150 (SD 0.09) °C. The proportion of outliers >1 °C was 4/251 children (1.59%). A significant correlation between temperature values obtained with the two procedures was observed (r(2) = 0.84; p < 0.0001). The limits of agreement, by the Bland and Altman method, were -0.62 (95% CI: -0.47 to -0.67) and 0.76 (95% CI: 0.61-0.91). No significant correlation was evidenced between the difference of the body temperature values recorded by the two methods and age (p = 0.226), or room temperature (p = 0.756). Calculating the receiver operating characteristic curve to determine the best threshold for axillary temperature >38.0 °C, for a non-contact infrared thermometer temperature = 37.98 °C the sensitivity was 88.7% and the specificity 89.9%. Mean distress score (on a 5-point scale) was significantly lower using the non-contact infrared thermometer than using the mercury-in-glass thermometer (1.92 SD 0.56 and 2.40 SD0.93, respectively; p < 0.0001). CONCLUSION Non-contact infrared thermometer showed a good performance in our study population, has the advantage of measuring body temperature in two seconds and is comfortable for children. RELEVANCE TO CLINICAL PRACTICE Non-contact infrared thermometer may be taken into consideration when assessing body temperature in children aged > one month in hospital or ambulatory.

[1]  A. Mugelli,et al.  Management of fever in children: summary of the Italian Pediatric Society guidelines. , 2009, Clinical therapeutics.

[2]  A. Van de Winckel,et al.  Reliability of infrared ear thermometry in the prediction of rectal temperature in older inpatients. , 2009, Journal of Clinical Nursing.

[3]  J. Chamberlain,et al.  Determination of normal ear temperature with an infrared emission detection thermometer. , 1995, Annals of emergency medicine.

[4]  Wt Chiu,et al.  Infrared Thermography to Mass-Screen Suspected Sars Patients with Fever , 2005, Asia-Pacific journal of public health.

[5]  J. Desenclos,et al.  International travels and fever screening during epidemics: a literature review on the effectiveness and potential use of non-contact infrared thermometers. , 2009, Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin.

[6]  Ron Dagan,et al.  Fever as an adverse event following immunization: case definition and guidelines of data collection, analysis, and presentation. , 2004, Vaccine.

[7]  M. Ozaki,et al.  The accuracy and precision of four infrared aural canal thermometers during cardiac surgery , 1998, Acta anaesthesiologica Scandinavica.

[8]  A S El-Radhi,et al.  Thermometry in paediatric practice , 2006, Archives of Disease in Childhood.

[9]  Necdet Süt,et al.  Comparison of temporal artery, mid‐forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight * , 2009, Journal of paediatrics and child health.

[10]  Paula R Williamson,et al.  Infrared ear thermometry compared with rectal thermometry in children: a systematic review , 2002, The Lancet.

[11]  Sandra Mounier-Jack,et al.  Progress and shortcomings in European national strategic plans for pandemic influenza. , 2007, Bulletin of the World Health Organization.

[12]  A. Kara,et al.  Measurement Accuracy of Fever by Tympanic and Axillary Thermometry , 2007, Pediatric emergency care.

[13]  T. Terndrup,et al.  Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures. , 1996, Critical care medicine.

[14]  C. Wong,et al.  Non-contact infrared thermal imagers for mass fever screening--state of the art or myth? , 2006, Hong Kong medical journal = Xianggang yi xue za zhi.

[15]  C E Osio,et al.  Comparative study of body temperature measured with a non-contact infrared thermometer versus conventional devices. The first Italian study on 90 pediatric patients. , 2007, Minerva pediatrica.

[16]  G. Fleisher,et al.  Accuracy of a noninvasive temporal artery thermometer for use in infants. , 2001, Archives of pediatrics & adolescent medicine.

[17]  A. Albert,et al.  Comparison of Rectal and Infrared Ear Temperatures in Older Hospital Inpatients , 2000, Journal of the American Geriatrics Society.

[18]  H. Bernstein,et al.  Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population. , 2002, The Journal of pediatrics.

[19]  S. Fuchs,et al.  Efficacy of rectal midazolam for the sedation of preschool children undergoing laceration repair. , 1994, Annals of emergency medicine.

[20]  P. Williamson,et al.  In a systematic review, infrared ear thermometry for fever diagnosis in children finds poor sensitivity. , 2006, Journal of clinical epidemiology.

[21]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[22]  I. Lauder,et al.  Screening for fever by remote-sensing infrared thermographic camera. , 2006, Journal of travel medicine.

[23]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[24]  B. Riou,et al.  Cutaneous Infrared Thermometry for Detecting Febrile Patients , 2008, Emerging infectious diseases.

[25]  G. Barba,et al.  Comparison between rectal and infrared skin temperature in the newborn , 2007, Archives of Disease in Childhood Fetal and Neonatal Edition.

[26]  Chung-Hong Chan,et al.  Non-contact infrared thermometry temperature measurement for screening fever in children , 2005, Annals of tropical paediatrics.

[27]  Wen-Cheng Chang,et al.  Limitations of Forehead Infrared Body Temperature Detection for Fever Screening for Severe Acute Respiratory Syndrome , 2004, Infection Control &#x0026; Hospital Epidemiology.