Comparison of epoxy and braze-welded attachment methods for FBG strain gauges

This paper presents experimental results from fatigue and static loading tests performed on both epoxy and braze-welded FBG strain sensors. Most FBG attachment methods are relatively understudied, with epoxy the most commonly used. Long curing times and humidity sensitivity during curing render epoxy inappropriate for certain implementations. This work shows that a bespoke braze-welded attachment design is able to achieve a higher static failure limit of 22kN when compared to strain gauge epoxies, which fail at 20kN. Both methods demonstrate high fatigue life, with no significant deterioration after two million cycles. Epoxy swelling was observed when the sensors were held at a relative humidity of 96%, applying ∼0.6 me of tension to the FBG, whereas a braze-weld attachment was unaffected by humidity.

[1]  Grzegorz Fusiek,et al.  First-time demonstration of measuring concrete prestress levels with metal packaged fibre optic sensors , 2016 .

[2]  Aníbal Costa,et al.  Structural Health Monitoring of the Church of Santa Casa da MisericÓrdia of Aveiro Using FBG Sensors , 2008 .

[3]  Tommy H.T. Chan,et al.  Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge : Background and experimental observation , 2006 .

[4]  G. Fusiek,et al.  Metal-packaged fibre Bragg grating strain sensors for surface-mounting onto spalled concrete wind turbine foundations , 2015, International Conference on Optical Fibre Sensors.

[5]  W. Lance Richards,et al.  Large Scale Applications Using FBG Sensors: Determination of In-Flight Loads and Shape of a Composite Aircraft Wing , 2016 .

[6]  Grzegorz Fusiek,et al.  Induction heating assisted optical fiber bonding and sealing technique , 2011, International Conference on Optical Fibre Sensors.

[7]  J. Canning,et al.  Induction Brazing of Type-I Fiber Bragg Gratings Into Kovar Ferrules Exploiting Curie Transition , 2013, IEEE Sensors Journal.

[8]  Chiara Grappasonni,et al.  Development of a FBG based distributed strain sensor system for wind turbine structural health monitoring , 2013 .

[9]  A. Wexler,et al.  Relative Humidity-Temperature Relationships of Some Saturated Salt Solutions in the Temperature Range 0 0 to 50 0 C 1 , 2011 .

[10]  A. Wexler,et al.  Relative humidity-temperature relationships of some saturated salt solutions in the temperature range 0 degree to 50 degrees C , 1954 .

[11]  N. Djilali,et al.  In-fibre Bragg grating sensors for distributed temperature measurement in a polymer electrolyte membrane fuel cell , 2009 .

[12]  Kyriacos Kalli,et al.  Fibre Bragg Gratings , 2006 .