A marker-based mean finite helical axis model to determine elbow rotation axes and kinematics in vivo.

The predominance of upper-limb elbow models have been based on earlier lower-limb motion analysis models. We developed and validated a functionally based 2 degree-of-freedom upper-limb model to measure rotations of the forearm using a marker-based approach. Data were collected from humans and a mechanical arm with known axes and ranges of angular motion in 3 planes. This upper-limb model was compared with an anatomically based model following the proposed ISB standardization. Location of the axes of rotation relative to each other was determined in vivo. Data indicated that the functional model was not influenced by cross-talk from adduction-abduction, accurately measuring flexion-extension and pronation-supination. The functional flexion-extension axis in vivo is angled at 6.6 degrees to the anatomical line defined from the humeral medial to lateral epicondyles. The pronation-supination axis intersected the anatomically defined flexion-extension axis at 88.1 degrees. Influence of cross-talk on flexion-extension kinematics in the anatomical model was indicated by strong correlation between flexion-extension and adduction-abduction angles for tasks performed by the subjects. The proposed functional model eliminated cross-talk by sharing a common flexion axis between the humerus and forearm. In doing so, errors due to misalignment of axes are minimized providing greater accuracy in kinematic data.

[1]  Herman J. Woltring,et al.  A fortran package for generalized, cross-validatory spline smoothing and differentiation , 1986 .

[2]  Anita Bagley,et al.  A method for determination of upper extremity kinematics. , 2002, Gait & posture.

[3]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[4]  Y. Youm,et al.  Biomechanical analyses of forearm pronation-supination and elbow flexion-extension. , 1979, Journal of biomechanics.

[5]  A Leardini,et al.  Position and orientation in space of bones during movement: anatomical frame definition and determination. , 1995, Clinical biomechanics.

[6]  E V Biryukova,et al.  Kinematics of human arm reconstructed from spatial tracking system recordings. , 2000, Journal of biomechanics.

[7]  G Rau,et al.  Movement biomechanics goes upwards: from the leg to the arm. , 2000, Journal of biomechanics.

[8]  C Disselhorst-Klug,et al.  A marker-based measurement procedure for unconstrained wrist and elbow motions. , 1999, Journal of biomechanics.

[9]  Bo Zhang,et al.  Simulation of Elbow and Forearm Motion In Vitro Using an Active Controlled Testing System , 2010, 2010 4th International Conference on Bioinformatics and Biomedical Engineering.

[10]  K. An,et al.  Parameters for modeling the upper extremity. , 1997, Journal of biomechanics.

[11]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[12]  S. Piazza,et al.  Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. , 2000, Journal of biomechanics.

[13]  B. Fregly,et al.  Determination of joint functional axes from noisy marker data using the finite helical axis , 1998 .

[14]  H E Veeger,et al.  Determination of the optimal elbow axis for evaluation of placement of prostheses. , 1999, Clinical biomechanics.

[15]  C E Dunning,et al.  Simulation of elbow and forearm motion in vitro using a load controlled testing apparatus. , 2000, Journal of biomechanics.

[16]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[17]  Angelo Cappello,et al.  How accurate is the estimation of elbow kinematics using ISB recommended joint coordinate systems , 2006 .

[18]  H E Veeger,et al.  Determining the optimal flexion-extension axis of the elbow in vivo - a study of interobserver and intraobserver reliability. , 2000, Journal of biomechanics.

[19]  U. Wyss,et al.  Review of arm motion analyses , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  E Y Chao,et al.  Three-dimensional rotation of the elbow. , 1978, Journal of biomechanics.

[21]  Jaap Harlaar,et al.  Complete 3D kinematics of upper extremity functional tasks. , 2008, Gait & posture.

[22]  Laura Rocchi,et al.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors , 2008, Medical & Biological Engineering & Computing.

[23]  A. Lundberg,et al.  Variation in the position and orientation of the elbow flexion axis. , 2003, The Journal of bone and joint surgery. British volume.

[24]  Jonathan Wheat,et al.  Orientation of axes in the elbow and forearm for biomechanical modeling , 2005 .

[25]  David G Lloyd,et al.  Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. , 2003, Journal of biomechanics.

[26]  Thay Q. Lee,et al.  Anatomy and Biomechanics of the Elbow Joint , 2003 .