Head-Neck Osteoplasty has Minor Effect on the Strength of an Ovine Cam-FAI Model: In Vitro and Finite Element Analyses

BackgroundOsteochondroplasty of the head-neck region is performed on patients with cam femoroacetabular impingement (FAI) without fully understanding its repercussion on the integrity of the femur. Cam-type FAI can be surgically and reproducibly induced in the ovine femur, which makes it suitable for studying corrective surgery in a consistent way. Finite element models built on quantitative CT (QCT) are computer tools that can be used to predict femoral strength and evaluate the mechanical effect of surgical correction.Questions/purposesWe asked: (1) What is the effect of a resection of the superolateral aspect of the ovine femoral head-neck junction on failure load? (2) How does the failure load after osteochondroplasty compare with reported forces from activities of daily living in sheep? (3) How do failure loads and failure locations from the computer simulations compare with the experiments?MethodsOsteochondroplasties (3, 6, 9 mm) were performed on one side of 18 ovine femoral pairs with the contralateral intact side as a control. The 36 femurs were scanned via QCT from which specimen-specific computer models were built. Destructive compression tests then were conducted experimentally using a servohydraulic testing system and numerically via the computer models. Safety factors were calculated as the ratio of the maximal force measured in vivo by telemeterized hip implants during the sheep’s walking and running activities to the failure load. The simulated failure loads and failure locations from the computer models were compared with the experimental results.ResultsFailure loads were reduced by 5% (95% CI, 2%–8%) for the 3-mm group (p = 0.0089), 10% (95% CI, 6%–14%) for the 6-mm group (p = 0.0015), and 19% (95% CI, 13%–26%) for the 9-mm group (p = 0.0097) compared with the controls. Yet, the weakest specimen still supported more than 2.4 times the peak load during running. Strong correspondence was found between the simulated and experimental failure loads (R2 = 0.83; p < 0.001) and failure locations.ConclusionsThe resistance of ovine femurs to fracture decreased with deeper resections. However, under in vitro testing conditions, the effect on femoral strength remains small even after 9 mm correction, suggesting that femoral head-neck osteochondroplasty could be done safely on the ovine femur. QCT-based finite element models were able to predict weakening of the femur resulting from the osteochondroplasty.Clinical RelevanceThe ovine femur provides a seemingly safe platform for scientific evaluation of FAI. It also appears that computer models based on preoperative CT scans may have the potential to provide patient-specific guidelines for preventing overcorrection of cam FAI.

[1]  P. Zysset,et al.  Finite element analysis for prediction of bone strength. , 2013, BoneKEy reports.

[2]  R. Giardino,et al.  Sheep model in orthopedic research: a literature review. , 2001, Comparative medicine.

[3]  M. Tannast,et al.  Experimentally induced cam impingement in the sheep hip , 2013, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  P. Zysset,et al.  Rehydration of vertebral trabecular bone: influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level. , 2010, Bone.

[5]  A Rohlmann,et al.  Hip joint forces in sheep. , 1999, Journal of biomechanics.

[6]  P. Zysset,et al.  An anisotropic elastic-viscoplastic damage model for bone tissue , 2012, Biomechanics and Modeling in Mechanobiology.

[7]  Kenton R Kaufman,et al.  Surgical treatment of femoroacetabular impingement: evaluation of the effect of the size of the resection. , 2005, The Journal of bone and joint surgery. American volume.

[8]  P. Zysset,et al.  Nonlinear quasi-static finite element simulations predict in vitro strength of human proximal femora assessed in a dynamic sideways fall setup. , 2016, Journal of the mechanical behavior of biomedical materials.

[9]  W. Taylor,et al.  European Society of Biomechanics S.M. Perren Award 2014: Safety factor of the proximal femur during gait: a population-based finite element study. , 2014, Journal of biomechanics.

[10]  Michael M. Morlock,et al.  Compressive strength of elderly vertebrae is reduced by disc degeneration and additional flexion. , 2015, Journal of the mechanical behavior of biomedical materials.

[11]  F. Eckstein,et al.  Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur. , 2012, Bone.

[12]  Benjamin Schmid,et al.  A high-level 3D visualization API for Java and ImageJ , 2010, BMC Bioinformatics.

[13]  E. Dall’Ara,et al.  Orthotropic HR-pQCT-based FE models improve strength predictions for stance but not for side-way fall loading compared to isotropic QCT-based FE models of human femurs. , 2014, Journal of the mechanical behavior of biomedical materials.

[14]  Jamshid Tehranzadeh,et al.  Predicting Proximal Femoral Strength Using Structural Engineering Models , 2005, Clinical orthopaedics and related research.

[15]  D. Carter,et al.  Cyclic mechanical property degradation during fatigue loading of cortical bone. , 1996, Journal of biomechanics.

[16]  Mitchell B. Schaffler,et al.  Role of bone turnover in microdamage , 2003, Osteoporosis International.

[17]  Kozo Nakamura,et al.  Prediction of strength and strain of the proximal femur by a CT-based finite element method. , 2007, Journal of biomechanics.

[18]  Kevin W Eliceiri,et al.  NIH Image to ImageJ: 25 years of image analysis , 2012, Nature Methods.

[19]  J. Snedeker,et al.  Influence of Resection Geometry on Fracture Risk in the Treatment of Femoroacetabular Impingement , 2012, The American journal of sports medicine.

[20]  L. Rapillard,et al.  Compressive fatigue behavior of human vertebral trabecular bone. , 2006, Journal of biomechanics.

[21]  Andrew H. Gee,et al.  Independent measurement of femoral cortical thickness and cortical bone density using clinical CT , 2015, Medical Image Anal..

[22]  R. Dussault,et al.  [Stress fractures of the femoral neck]. , 1988, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[23]  Majid Mirzaei,et al.  Analysis of strength and failure pattern of human proximal femur using quantitative computed tomography (QCT)-based finite element method. , 2014, Bone.

[24]  Philippe K. Zysset,et al.  Multi-axial mechanical properties of human trabecular bone , 2009, Biomechanics and modeling in mechanobiology.

[25]  David Larsson,et al.  Assessment of Transverse Isotropy in Clinical-Level CT Images of Trabecular Bone Using the Gradient Structure Tensor , 2014, Annals of Biomedical Engineering.

[26]  F. Kainberger,et al.  A nonlinear QCT-based finite element model validation study for the human femur tested in two configurations in vitro. , 2013, Bone.

[27]  S. Khosla,et al.  Comprehensive Assessment of Osteoporosis and Bone Fragility with CT Colonography. , 2016, Radiology.

[28]  P. Zysset,et al.  Bone Volume Fraction and Fabric Anisotropy Are Better Determinants of Trabecular Bone Stiffness Than Other Morphological Variables , 2015, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[29]  M. Tannast,et al.  Biochemical MRI Predicts Hip Osteoarthritis in an Experimental Ovine Femoroacetabular Impingement Model , 2015, Clinical orthopaedics and related research.

[30]  P. Augat,et al.  Finite element analysis of the ovine hip: Development, results and comparison with the human hip , 2012, Veterinary and Comparative Orthopaedics and Traumatology.

[31]  F. O'Brien,et al.  Biomechanical properties across trabeculae from the proximal femur of normal and ovariectomised sheep. , 2009, Journal of biomechanics.