Recent Advances in Polymeric Heart Valves Research

Heart valve replacement is fast becoming a routine surgery worldwide, and heart valve prostheses are today considered among the most widely used cardiovascular devices. Mechanical and bioprostheses have been the traditional choices to the replacement surgeries. However, such valves continue to expose patients to risks including thrombosis, infection and limited valve durability. In recent years, advances in polymer science give rise to an important new class of artificial heart valve made predominantly of polyurethane-based materials, which show improved biocompatibility and biostability. These polymeric heart valves have demonstrated excellent hemodynamic performance and good durability with excellent fatigue stress resistance. Advancements in the designs and manufacturing methods also suggested improved in the durability of polymeric heart valves. Animal studies with these valves have also shown good biocompatibility with minimal calcification of the valve leaflets. With these promising progresses, polymeric heart valves could be a viable alternative in the heart valve replacement surgeries in the near future. DOI: 10.4018/ijbre.2011010101 2 International Journal of Biomaterials Research and Engineering, 1(1), 1-17, January-March 2011 Copyright © 2011, IGI Global. Copying or distributing in print or electronic forms without written permission of IGI Global is prohibited. One major drawbacks associated with the implantation of mechanical heart valves is the need for daily chronic anticoagulation therapy to reduce the risk of thrombosis and thromboembolic complications. These patients are expose to an increased risk of bleeding, infection, and/ or autoimmune response (Walker, & Yoganathan, 1992). Blood flow through mechanical prostheses can lead to high turbulent stresses that may damage and/or activate blood elements and initiate platelet aggregation. Platelet aggregation can lead to thrombus formation with disastrous consequences for the patient. Thrombi may even detach from the valve and become lodged in a downstream blood vessel, thus reducing or even cutting off the blood supply to vital tissues. An alternative to mechanical valves is using tissue valves which utilize the concept of a trileaflet configuration with one central orifice that mimics the design of the native valve. These valves have a lower potential for blood element damage than their mechanical counterparts. Nevertheless, the mechanical properties of tissue valves appear to degrade more rapidly, and they are prone to calcification (Black & Drury, 1994). Often, implanted tissue valves do not last for more than ten years, and reoperation is necessary. The polyurethane (PU) trileaflet polymeric heart valve is the latest development in prosthetic heart valve research (Hyde, Chinn, & Phillips, 1999). The design is based on the natural aortic valve and is inherently appealing from a hemodynamic viewpoint. Although this particular valve design is still in a developmental stage, preliminary studies have shown excellent forward flow hemodynamic properties equivalent to that of a tissue heart valve and promise a durability comparable to that of a mechanical heart valve (Bernacca, Mackay, Wilkinson, & Wheatley, 1995; Jansen et al., 1991). However, recent animal trials involving polymeric valves have reported problems mainly related to tearing of the leaflets and thrombus formation occuring along the stent region of the valve (Wheatley et al., 2001). In addition, results of long-term in vivo evaluation have suggested that calcification could be a limiting factor to long-term function of polymeric valves (Bodnar & Frater, 1991). The leaflets and basal attachments, such as the commissural region of the polymer valves, have experienced extrinsic calcification associated with surface microthrombi that appear to be independent of structural defects suggesting that the flow characteristics inside the polymeric valve may be a contributor to the observed blood clots. This review will discuss the recent development of polymeric heart valves, particularly on its choice of materials. Much attention will also focus on the in vitro hemodynamics characterization these polymeric heart valves. The review will also discuss the in vivo experiments involving these polymeric heart valves and their susceptibility to calcifications. Introduction of Polymeric Heart Valves Pioneering works in polymeric heart valve replacement in human was first reported in 1958 (Roe, Owsley, & Boudoures, 1958). This is followed by a single trileaflet silicone rubber (SR) aortic valve implanted in several patients between 1960 and 1962 (Roe, Kelly, Myers, & Moore, 1966). The clinical trials were discontinued due to the high occurrence of thromboembolic events. The choice of material is an important factor in the development of polymeric heart valve. The chosen polymer should have acceptable characteristics with regard to biocompatibility, hemocompatibility, anti-thrombogenicity, resistance to degradation and calcification (Daebritz et al., 2004; Gallocher, Aguirre, Kasyanov, Pinchuk, & Schoephoerster, 2006). Since then, several synthetic polymers have been tested as leaflet materials, including silicone, polyofelin rubber, Silastic, SR-impregnated Dacron mesh, polytetrafluoroethylene (PTPE) and PU. In 1960s, silicone was considered a choice due to its great flexibility and biocompatibility. However, in clinical investigations, formation of thrombosis and thickening of valve leaflets were found. Silicone suffered from structural 15 more pages are available in the full version of this document, which may be purchased using the "Add to Cart" button on the product's webpage: www.igi-global.com/article/recent-advances-polymeric-heartvalves/63610?camid=4v1 This title is available in InfoSci-Journals, InfoSci-Journal Disciplines Medicine, Healthcare, and Life Science. Recommend this product to your librarian: www.igi-global.com/e-resources/libraryrecommendation/?id=2

[1]  B. B. Roe,et al.  Experimental results with a prosthetic aortic valve. , 1958, The Journal of thoracic surgery.

[2]  W J KOLFF,et al.  Polyurethane artificial heart valves in animals. , 1959, Journal of applied physiology.

[3]  A C Beall,et al.  [Replacement of cardiac valves]. , 1965, Annales de chirurgie thoracique et cardio-vasculaire.

[4]  P. B. Kelly,et al.  Tricuspid Leaflet Aortic Valve Prosthesis , 1966, Circulation.

[5]  C. Hufnagel,et al.  Cardiac valve replacement-its current status. , 1966, The Medical annals of the District of Columbia.

[6]  R Langendorf,et al.  Elective Countershock in Unanesthetized Patients with Use of an Esophageal Electrode , 1966, Circulation.

[7]  B J Bellhouse,et al.  Fluid mechanics of the aortic valve. , 1969, British heart journal.

[8]  B J Bellhouse,et al.  Instantaneous velocity measurement in major blood vessels: its value in the study of normal and abnormal circulation. , 1969, British heart journal.

[9]  J. Mercer,et al.  The geometry and construction of the aortic leaflet. , 1973, The Journal of thoracic and cardiovascular surgery.

[10]  D. Dillard,et al.  Design and durability test of Silastic trileaflet aortic valve prostheses. , 1973, The Journal of thoracic and cardiovascular surgery.

[11]  Reflections on the development of valvular prostheses. , 1977, Medical instrumentation.

[12]  E Imamura,et al.  Function of expanded-polytetrafluoroethylene laminated trileaflet valves in animals. , 1977, Mayo Clinic proceedings.

[13]  Hufnagel Ca Reflections on the development of valvular prostheses. , 1977 .

[14]  G E Chetta,et al.  The design, fabrication and evaluation of a trileaflet prosthetic heart valve. , 1980, Journal of biomechanical engineering.

[15]  W S Pierce,et al.  A polyurethane trileaflet cardiac valve prosthesis: in vitro and in vivo studies. , 1982, Transactions - American Society for Artificial Internal Organs.

[16]  E. C. Harrison,et al.  In vitro fluid dynamic characteristics of Ionescu-Shiley and Carpentier-Edwards tissue bioprostheses. , 1983, Artificial organs.

[17]  A P Yoganathan,et al.  In-vitro fluid dynamic characteristics of the abiomed trileaflet heart valve prosthesis. , 1983, Journal of biomechanical engineering.

[18]  Steady and pulsatile flow studies on a trileaflet heart valve prosthesis. , 1983, Scandinavian journal of thoracic and cardiovascular surgery.

[19]  M Jones,et al.  In vitro hemodynamic characteristics of tissue bioprostheses in the aortic position. , 1986, The Journal of thoracic and cardiovascular surgery.

[20]  A P Yoganathan,et al.  Turbulent shear stress measurements in the vicinity of aortic heart valve prostheses. , 1986, Journal of biomechanics.

[21]  M Szycher,et al.  Biostability of Polyurethane Elastomers: A Critical Review , 1988, Journal of biomaterials applications.

[22]  K. Chandran,et al.  In vitro comparison of velocity profiles and turbulent shear distal to polyurethane trileaflet and pericardial prosthetic valves. , 1989, Artificial organs.

[23]  F. Nistal,et al.  In vivo experimental assessment of polytetrafluoroethylene trileaflet heart valve prosthesis. , 1990, The Journal of thoracic and cardiovascular surgery.

[24]  H Reul,et al.  Advances in design principle and fluid dynamics of a flexible polymeric heart valve. , 1991, ASAIO transactions.

[25]  F J Schoen,et al.  Antimineralization treatments for bioprosthetic heart valves. Assessment of efficacy and safety. , 1992, The Journal of thoracic and cardiovascular surgery.

[26]  T. Mackay,et al.  Calcification Modelling in Artificial Heart Valves , 1992, The International journal of artificial organs.

[27]  A P Yoganathan,et al.  In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses. , 1992, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[28]  P. J. Drury,et al.  Mechanical and other problems of artificial valves. , 1994, Current topics in pathology. Ergebnisse der Pathologie.

[29]  J Fisher,et al.  A synthetic leaflet heart valve with improved opening characteristics. , 1994, Medical engineering & physics.

[30]  J Fisher,et al.  In Vitro Determination of the Curvatures and Bending Strains Acting on the Leaflets of Polyurethane Trileaflet Heart Valves During Leaflet Motion , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[31]  J Fisher,et al.  Determination of the Curvatures and Bending Strains in Open Trileaflet Heart Valves , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[32]  D J Wheatley,et al.  Calcification and fatigue failure in a polyurethane heart value. , 1995, Biomaterials.

[33]  James M. Anderson,et al.  Polyurethane Elastomer Biostability , 1995, Journal of biomaterials applications.

[34]  M E Leat,et al.  The Influence of Manufacturing Methods on the Function and Performance of a Synthetic Leaflet Heart Valve , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[35]  D J Wheatley,et al.  New polyurethane heart valve prosthesis: design, manufacture and evaluation. , 1996, Biomaterials.

[36]  J Fisher,et al.  Finite Element Stress Analysis of a New Design of Synthetic Leaflet Heart Valve , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[37]  D J Wheatley,et al.  In vitro function and durability of a polyurethane heart valve: material considerations. , 1996, The Journal of heart valve disease.

[38]  R. Levy,et al.  Current Progress in Anticalcif ication for Bioprosthetic and Polymeric Heart Valves. , 1997, Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology.

[39]  D J Wheatley,et al.  Polyurethane heart valves: fatigue failure, calcification, and polyurethane structure. , 1997, Journal of biomedical materials research.

[40]  D J Wheatley,et al.  Artificial Heart and Cardiac Assist Devices Polyurethane heart valve durability : effects of leaflet thickness and material , 2018 .

[41]  Polymer heart valves. , 1999, The Journal of heart valve disease.

[42]  Phillips Re,et al.  Polymer heart valves. , 1999 .

[43]  D J Wheatley,et al.  Polyurethane: material for the next generation of heart valve prostheses? , 2000, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[44]  F. Baaijens,et al.  A synthetic fiber-reinforced stentless heart valve. , 2000, Journal of biomechanics.

[45]  J Fisher,et al.  Cardiac valve replacement: a bioengineering approach. , 2000, Bio-medical materials and engineering.

[46]  I. Alferiev,et al.  Bisphosphonate derivatized polyurethanes resist calcification. , 2001, Biomaterials.

[47]  J Fisher,et al.  Hydrodynamic Function of a Biostable Polyurethane Flexible Heart Valve after Six Months in Sheep , 2001, The International journal of artificial organs.

[48]  Marianne Odlyha,et al.  Thermo-mechanical analysis of a compliant poly(carbonate-urea)urethane after exposure to hydrolytic, oxidative, peroxidative and biological solutions. , 2002, Biomaterials.

[49]  G. Grunkemeier,et al.  Heart Valve Replacement Surgery: Past, Present And Future , 2002, Clinical and experimental pharmacology & physiology.

[50]  G. M. Bernacca,et al.  Mechanical and morphological study of biostable polyurethane heart valve leaflets explanted from sheep. , 2002, Journal of biomedical materials research.

[51]  G. M. Bernacca,et al.  Hydrodynamic function of polyurethane prosthetic heart valves: influences of Young's modulus and leaflet thickness. , 2002, Biomaterials.

[52]  Bernd Klosterhalfen,et al.  Introduction of a Flexible Polymeric Heart Valve Prosthesis With Special Design for Mitral Position , 2003, Circulation.

[53]  John Fisher,et al.  Kinematics of synthetic flexible leaflet heart valves during accelerated testing. , 2003, The Journal of heart valve disease.

[54]  Alexander M Seifalian,et al.  In vivo biostability of a poly(carbonate-urea)urethane graft. , 2003, Biomaterials.

[55]  Andreas Franke,et al.  New flexible polymeric heart valve prostheses for the mitral and aortic positions. , 2004, The heart surgery forum.

[56]  Anne Hiltner,et al.  Oxidative mechanisms of poly(carbonate urethane) and poly(ether urethane) biodegradation: in vivo and in vitro correlations. , 2004, Journal of biomedical materials research. Part A.

[57]  Hongjun Jiang,et al.  Design and manufacture of a polyvinyl alcohol (PVA) cryogel tri-leaflet heart valve prosthesis. , 2004, Medical engineering & physics.

[58]  H. Leo An in vitro investigation of the flow fields through bileaflet and polymeric prosthetic heart valves. , 2005 .

[59]  Leonard Pinchuk,et al.  A novel polymer for potential use in a trileaflet heart valve. , 2006, Journal of biomedical materials research. Part B, Applied biomaterials.

[60]  Laurent Bozec,et al.  The antithrombogenic potential of a polyhedral oligomeric silsesquioxane (POSS) nanocomposite. , 2006, Biomacromolecules.

[61]  S. Daebritz,et al.  Novel “Biomechanical” Polymeric Valve Prostheses with Special Design for Aortic and Mitral Position: A Future Option for Pediatric Patients? , 2006, ASAIO journal.

[62]  Marianne Odlyha,et al.  Silsesquioxane Nanocomposites as Tissue Implants , 2007, Plastic and reconstructive surgery.

[63]  Gaetano Burriesci,et al.  A novel nanocomposite polymer for development of synthetic heart valve leaflets. , 2009, Acta biomaterialia.

[64]  Gaetano Burriesci,et al.  Polymeric heart valves: new materials, emerging hopes. , 2009, Trends in biotechnology.

[65]  Laurentiu Fara,et al.  QUANTUM CONFINEMENT MODELING AND SIMULATION FOR QUANTUM WELL SOLAR CELLS , 2009 .

[66]  Cristina Martinez-Fernandez,et al.  Nanotechnology, Firm Innovation and University-Industry Networks: The Case of the UWS1 Nanotechnology Network in Sydney , 2010 .

[67]  Michael D. Mehta,et al.  Understanding Advances in Nanotechnology: Minimizing Risks and Maximizing Benefits with Application of the Appropriate Governance Framework , 2011, Int. J. Nanotechnol. Mol. Comput..

[68]  International Journal of Nanotechnology and Molecular Computation , 2022 .