The voltage distortion in low-voltage networks caused by compact fluorescent lamps with electronic gear

Abstract Commonly used compact fluorescent lamps (CFLs) with electronic gear are characterized by extremely distorted current, with total harmonic distortion (THD) usually exceeding 100%. That is why they cause a significant voltage distortion in electrical installations. The principal goal of this research was to determine their maximum permissible share in the total load installed for commercial customers, at which voltage distortion is still acceptable (according to international standards). An analysis regarding a low-voltage electrical installation of a hotel, representing a typical commercial customer, showed that maximum permissible share should not exceed 10%. As this maximum permissible share could restrict the installment of the intended quantity of CFLs, the costs of two possible solutions for this problem – the use of filters or a new generation of CFLs with a high power factor – are compared.

[1]  M. Etezadi-Amoli,et al.  Power Factor and Harmonic Distortion Characteristics of Energy Efficient Lamps , 1989, IEEE Power Engineering Review.

[2]  Frangiskos V. Topalis Efficiency of energy saving lamps and harmonic distortion in distribution systems , 1993 .

[3]  Frangiskos V. Topalis,et al.  Advantages and disadvantages of the use of compact fluorescent lamps with electronic control gear , 2002 .

[4]  Georgios A. Vokas,et al.  Arbitrary waveform generator for harmonic distortion tests on compact fluorescent lamps , 2001 .

[5]  Emanuel Gluskin,et al.  The fluorescent lamp circuit , 1999 .

[6]  Ming-Tong Chen,et al.  Characteristics of fluorescent lamps under abnormal system voltage conditions , 1997 .

[7]  E. E. Hammer Effects of changing line voltage with various fluorescent systems , 1988 .

[8]  R. Arseneau,et al.  The effects of supply harmonics on the performance of compact fluorescent lamps , 1992 .

[9]  Giuseppe Fusco,et al.  Interaction between non-linear loads and synchronous generators , 2007 .

[10]  Alexander E. Emanuel,et al.  The effect of modern compact fluorescent lights on voltage distortion , 1993 .

[11]  Wang Xiao-yan,et al.  Difference of GB 1 7625.1-2003 《Electromagnetic Compatibility-Limits-Limits for Harmonic Current Emissions (Equipment Input Current Per Phase≤16A)》 , 2003 .

[12]  Tsai-Fu Wu,et al.  A PSpice circuit model for low-pressure gaseous discharge lamps operating at high frequency , 1997, IEEE Trans. Ind. Electron..