A Simple Method to Determine Double-Cage Rotor Equivalent Circuit Parameters of Induction Motors From No-Load and Locked-Rotor Tests

This paper presents a simple method to determine double-cage rotor equivalent circuit parameters of induction motors (IMs). A new formula to calculate the double-cage rotor equivalent circuit parameters is proposed. The formula is sufficiently simple to be calculated by a calculator but can determine the parameters of outer- and inner-cage conductors. The proposed method takes the magnetic saturation effect of a closed-slot rotor into account and applies to not only double-cage but also single-cage IMs. All equivalent circuit parameters can be determined using only classical no-load and locked-rotor tests. Thus, the proposed method is suitable to be used as a standardized testing method for IMs. The validity of the proposed method is demonstrated by experimental results on four 5.5 kW-200 V-4 P-22 A-50 Hz IMs: double- and single-cage IMs with semi-closed- and closed-slot rotors.

[1]  Paul Jacobs Defining the Equivalent Circuit of the Double-Cage Motor [includes discussion] , 1953, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[2]  Gabriel Kron Equivalent Circuits of Electric Machinery. , 1967 .

[3]  J. Pedra,et al.  Parameter estimation of squirrel-cage induction motors without torque measurements , 2006 .

[4]  R. Wamkeue,et al.  Unbalanced transients-based maximum likelihood identification of induction machine parameters , 1989 .

[5]  Willy Geysen,et al.  A circuit approach to finite element analysis of a double squirrel cage induction motor , 1990 .

[6]  Akira Tanaka,et al.  A simple method for determining equivalent circuit parameters of double-cage induction motors from no-load and locked-rotor tests , 2017, 2017 IEEE Energy Conversion Congress and Exposition (ECCE).

[7]  Antero Arkkio,et al.  Space-Vector Models for Torsional Vibration of Cage Induction Motors , 2015, IEEE Transactions on Industry Applications.

[8]  Lluis Monjo,et al.  Using the Instantaneous Power of a Free Acceleration Test for Squirrel-Cage Motor Parameters Estimation , 2015, IEEE Transactions on Energy Conversion.

[9]  Francisco Jurado,et al.  Shuffled frog-leaping algorithm for parameter estimation of a double-cage asynchronous machine , 2012 .

[10]  K. Matsuse,et al.  Prediction of starting performance of PM motor by DC decay testing method , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[11]  S. Williamson,et al.  Finite element calculation of double-cage rotor equivalent circuit parameters , 1996 .

[12]  Takashi Kano,et al.  A calculation method of equivalent circuit constants with mutual leakage reactance on synchronous machine with damper winding , 2009 .

[13]  S. A. soliman,et al.  Modeling of Induction Motors from Standstill Frequency Response Tests and a Parameter Estimation Algorithm , 1992 .

[14]  A.M.A. Mahmoud,et al.  A Complete Time Domain Model of the Induction Motor for Efficiency Evaluation , 1986, IEEE Transactions on Energy Conversion.

[15]  Shu Yamamoto,et al.  Universal Parameter Measurement and Sensorless Vector Control of Induction and Permanent Magnet Synchronous Motors , 2010 .

[16]  L. Sainz,et al.  Analysis of the Induction Machine Parameter Identification , 2002, IEEE Power Engineering Review.

[17]  B. J. Chalmers,et al.  Design synthesis of double-cage induction motors , 1970 .

[18]  John R Smith Response Analysis of A.C. Electrical Machines: Computer Models and Simulation , 1989 .

[19]  J. S. Edmonds,et al.  Derivation of Induction Motor Models from Standstill Frequency Response Tests , 1989, IEEE Power Engineering Review.