Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time.

OBJECT Percutaneous pedicle screws are used to provide rigid internal fixation in minimally invasive spinal procedures and generally require the use of Kirchner wires (or K-wires) as a guide for screw insertion. K-wires can bend, break, advance, or pull out during the steps of pedicle preparation and screw insertion. This can lead to increased fluoroscopic and surgical times and potentially cause neurological, vascular, or visceral injury. The authors present their experience with a novel "K-wireless" percutaneous pedicle screw system that eliminates the inherent risks of K-wire use. METHODS A total of 100 screws were placed in 28 patients using the K-wireless percutaneous screw system. Postoperative dedicated spinal CT scans were performed in 25 patients to assess the accuracy of screw placement. Screw placement was graded A through D by 2 independent radiologists: A = within pedicle, B = breach < 2 mm, C = breach of 2-4 mm, and D = breach > 4 mm. Screw insertion and fluoroscopy times were also recorded in each case. Clinical complications associated with screw insertion were documented. RESULTS A total of 100 K-wireless percutaneous pedicle screws were placed into the lumbosacral spine in 28 patients. Postoperative CT was performed in 25 patients, thus the placement of only 90 screws was assessed. Eighty-seven screws were placed within the pedicle confines (Grade A), and 3 violated the pedicle (2 Grade B [1 lateral, 1 medial] and 1 Grade D [medial]) for an overall accuracy rate of 96.7%. One patient required reoperation for screw repositioning due to a postoperative L-5 radiculopathy secondary to a Grade D medial breach at L-5. This patient experienced improvement of the radiculopathy after reoperation. Average screw insertion and fluoroscopy times were 6.92 minutes and 22.7 seconds per screw, respectively. CONCLUSIONS The results of this study demonstrate that the placement of K-wireless percutaneous pedicle screws is technically feasible and can be performed accurately and safely with short procedure and fluoroscopy times.

[1]  Raja Rampersaud,et al.  Clinical Accuracy of Computer-Assisted Two-Dimensional Fluoroscopy for the Percutaneous Placement of Lumbosacral Pedicle Screws , 2011, Spine.

[2]  E. Nottmeier,et al.  Three‐dimensional image‐guided placement of percutaneous pedicle screws without the use of biplanar fluoroscopy or Kirschner wires: technical note , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[3]  Y. Rampersaud,et al.  Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw Insertion , 2000, Spine.

[4]  P. Santiago,et al.  Minimally invasive microendoscopy-assisted transforaminal lumbar interbody fusion with instrumentation. , 2005, Journal of neurosurgery. Spine.

[5]  H. Matsui,et al.  Back Muscle Injury After Posterior Lumbar Spine Surgery: A Histologic and Enzymatic Analysis , 1996, Spine.

[6]  Bernhard Meyer,et al.  Minimally Invasive Transmuscular Pedicle Screw Fixation of the Thoracic and Lumbar Spine , 2006, Neurosurgery.

[7]  F. Magerl Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. , 1984, Clinical orthopaedics and related research.

[8]  Paul Park,et al.  Minimally invasive transforaminal lumbar interbody fusion with reduction of spondylolisthesis: technique and outcomes after a minimum of 2 years' follow-up. , 2008, Neurosurgical focus.

[9]  M. Blauth,et al.  Transpedicular screw fixation on the thoracolumbar spine , 1999, Der Orthopäde.

[10]  Constantin Schizas,et al.  Pedicle Screw Placement Accuracy: A Meta-analysis , 2007, Spine.

[11]  M. Bawa,et al.  Percutaneous Lumbar and Thoracic Pedicle Screws: A Trauma Experience , 2014, Journal of spinal disorders & techniques.

[12]  S. Dhall,et al.  Clinical and radiographic comparison of mini-open transforaminal lumbar interbody fusion with open transforaminal lumbar interbody fusion in 42 patients with long-term follow-up. , 2008, Journal of neurosurgery. Spine.

[13]  Koichi Sugimoto,et al.  Incidence of Lumbar Spine Pedicle Breach After Percutaneous Screw Fixation: A Radiographic Evaluation of 601 Screws in 151 Patients , 2014, Journal of spinal disorders & techniques.

[14]  Nikolaos K. Paschos,et al.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques , 2012, European Spine Journal.

[15]  B. Green,et al.  Computer-assisted Fluoroscopic Targeting System for Pedicle Screw Insertion , 2000, Neurosurgery.

[16]  P. Heini,et al.  Fatal Cardiac Tamponade Associated With Posterior Spinal Instrumentation: A Case Report , 1998, Spine.

[17]  T. Laine,et al.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients , 2000, European Spine Journal.

[18]  Jérôme Tonetti,et al.  Fluoroscopy-based navigation system in spine surgery , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  H. Deutsch,et al.  Minimally Invasive Transpedicular Vertebrectomy for Metastatic Disease to the Thoracic Spine , 2008, Journal of spinal disorders & techniques.

[20]  Jean-Paul Wolinsky,et al.  Accuracy of Free-Hand Pedicle Screws in the Thoracic and Lumbar Spine: Analysis of 6816 Consecutive Screws , 2011, Neurosurgery.

[21]  I. Lieberman,et al.  Radiation Exposure to the Surgeon During Percutaneous Pedicle Screw Placement , 2011, Journal of spinal disorders & techniques.

[22]  R. Gaines The Use of Pedicle-Screw Internal Fixation for the Operative Treatment of Spinal Disorders* , 2000, The Journal of bone and joint surgery. American volume.

[23]  V. Podichetty,et al.  Placement of percutaneous pedicle screws without imaging guidance. , 2006, Neurosurgical Focus.

[24]  Constantin Schizas,et al.  Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization , 2007, European Spine Journal.

[25]  Choll W. Kim,et al.  Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. , 2008, The spine journal : official journal of the North American Spine Society.

[26]  Michael Y. Wang,et al.  Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients. , 2010, Journal of neurosurgery. Spine.

[27]  A. Mcgregor,et al.  BACK PAIN AND DISABILITY AFTER LUMBAR LAMINECTOMY: IS THERE A RELATIONSHIP TO MUSCLE RETRACTION? , 2004, Neurosurgery.

[28]  W Rüther,et al.  Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. , 2000, Spine.

[29]  S. Glaze,et al.  Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. , 2008, Journal of neurosurgery. Spine.

[30]  C. Ohaegbulam Minimally Invasive Transmuscular Pedicle Screw Fixation of the Thoracic and Lumbar Spine , 2008 .

[31]  川口 善治,et al.  Back muscle injury after posterior lumbar spine surgery , 1994 .

[32]  R. Fessler,et al.  A Minimally Invasive Technique for Decompression of the Lumbar Spine , 2002, Spine.

[33]  Kevin T Foley,et al.  Minimally Invasive Transforaminal Lumbar Interbody Fusion (TLIF): Technical Feasibility and Initial Results , 2005, Journal of spinal disorders & techniques.

[34]  R. Turner,et al.  Bilateral decompressive surgery in lumbar spinal stenosis associated with spondylolisthesis: unilateral approach and use of a microscope and tubular retractor system. , 2002, Neurosurgical focus.

[35]  M. Blauth,et al.  [Transpedicular implantation of screws in the thoracolumbar spine. Results of a survey of methods, frequency and complications]. , 1999, Der Orthopade.

[36]  Kevin T Foley,et al.  Minimally invasive transforaminal lumbar interbody fusion: indications, technique, and complications. , 2006, Neurosurgical focus.

[37]  A. Pompili,et al.  Minimally invasive resection of intradural-extramedullary spinal neoplasms. , 2006, Neurosurgery.

[38]  J. Voyadzis,et al.  The Learning Curve in Minimally Invasive Spine Surgery , 2011 .

[39]  Tsung-Ting Tsai,et al.  Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study. , 2004, Acta orthopaedica Scandinavica.

[40]  H. Matsui,et al.  Serial changes in trunk muscle performance after posterior lumbar surgery. , 1999, Spine.

[41]  R. Mobbs,et al.  Complications With K-Wire Insertion for Percutaneous Pedicle Screws , 2014, Journal of spinal disorders & techniques.

[42]  Mikael Gunnarsson,et al.  Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery , 2012, Journal of spinal disorders & techniques.

[43]  A. Alho,et al.  Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patients , 2005, European Spine Journal.

[44]  F. Magerl,et al.  Percutaneous diagnostic stabilization for low back pain. Correlation with results after fusion operations. , 1994, Clinical orthopaedics and related research.

[45]  V. Vougioukas,et al.  PERCUTANEOUS TRANSFORAMINAL LUMBAR INTERBODY FUSION FOR THE TREATMENT OF DEGENERATIVE LUMBAR INSTABILITY , 2007, Neurosurgery.

[46]  R Roy-Camille,et al.  Internal fixation of the lumbar spine with pedicle screw plating. , 1986, Clinical orthopaedics and related research.

[47]  L. Wiltse,et al.  New uses and refinements of the paraspinal approach to the lumbar spine. , 1988, Spine.

[48]  W. Castro,et al.  Accuracy of Pedicle Screw Placement in Lumbar Vertebrae , 1996, Spine.

[49]  G. Lowery,et al.  Posterior percutaneous spine instrumentation , 2000, European Spine Journal.

[50]  Yung Park,et al.  Comparison of One-Level Posterior Lumbar Interbody Fusion Performed With a Minimally Invasive Approach or a Traditional Open Approach , 2007, Spine.

[51]  Kevin T Foley,et al.  Minimally Invasive Lumbar Fusion , 2003, Spine.

[52]  S. Gertzbein,et al.  Accuracy of Pedicular Screw Placement In Vivo , 1990, Spine.

[53]  W. Rüther,et al.  Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. , 1999, Spine.

[54]  S. O’laoire,et al.  Relief of lumbar canal stenosis using multilevel subarticular fenestrations as an alternative to wide laminectomy: preliminary report. , 1988, Neurosurgery.