Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis.

AIMS The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. CONCLUSION This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.

[1]  D. Capodanno,et al.  Early- and mid-term outcomes of transcatheter aortic valve implantation in patients with logistic EuroSCORE less than 20%: a comparative analysis between different risk strata. , 2012, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  A. D. Cunningham,et al.  Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. , 2011, Journal of the American College of Cardiology.

[3]  Antonio Colombo,et al.  One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: The European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve , 2011, Circulation.

[4]  Stuart J Pocock,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[5]  Stuart J Head,et al.  A crucial factor in shared decision making: the team approach , 2011, The Lancet.

[6]  D. Wood,et al.  Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the Valve Academic Research Consortium (VARC) guidelines. , 2011, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[7]  P. Serruys,et al.  2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis. , 2011, Journal of the American College of Cardiology.

[8]  W. O’Neill,et al.  Early and late (one year) outcomes following transcatheter aortic valve implantation in patients with severe aortic stenosis (from the United States REVIVAL trial). , 2011, The American journal of cardiology.

[9]  F. Maisano,et al.  Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis , 2011, Circulation.

[10]  Pascal Vranckx,et al.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. , 2011, Journal of the American College of Cardiology.

[11]  H. Eggebrecht,et al.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry. , 2011, European heart journal.

[12]  Alain Cribier,et al.  Percutaneous transarterial aortic valve implantation: what do we know? , 2011, European heart journal.

[13]  Alain Prat,et al.  Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. , 2011, European heart journal.

[14]  E. Tay,et al.  An embolic deflection device for aortic valve interventions. , 2010, JACC. Cardiovascular interventions.

[15]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[16]  E. Tay,et al.  Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort , 2010, Circulation.

[17]  A. Colombo,et al.  Safety and Efficacy of the Subclavian Approach for Transcatheter Aortic Valve Implantation With the CoreValve Revalving System , 2010, Circulation. Cardiovascular interventions.

[18]  Fabian Nietlispach,et al.  Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. , 2010, Journal of the American College of Cardiology.

[19]  Philippe Pibarot,et al.  Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic valve replacement , 2009, European heart journal.

[20]  D. Capodanno,et al.  Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis. , 2009, The Journal of invasive cardiology.

[21]  Francesco Maisano,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[22]  N. Al-Attar,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European heart journal.

[23]  Chris A Rogers,et al.  Increased Mortality, Postoperative Morbidity, and Cost After Red Blood Cell Transfusion in Patients Having Cardiac Surgery , 2007, Circulation.

[24]  A. Garg,et al.  Chronic kidney disease and mortality risk: a systematic review. , 2006, Journal of the American Society of Nephrology : JASN.

[25]  J. Sharma Poor outcome after first-ever stroke. , 2003, Stroke.

[26]  M. Viitanen,et al.  Poor Outcome After First-Ever Stroke: Predictors for Death, Dependency, and Recurrent Stroke Within the First Year , 2003, Stroke.

[27]  S. Nashef,et al.  Risk factors for early mortality after valve surgery in Europe in the 1990s: lessons from the EuroSCORE pilot program. , 2001, The Journal of heart valve disease.