Evaluation of metabolism from heart rate in industrial work.

Oxygen consumption ([Vdot]O2) and heart rate (HR) were measured in 40 men performing different types of industrial work in eight factories A [Vdot]O2-HR relationship was established for each subject using an exercise test on a bicycle ergometer. HR measured during the industrial work was entered in the [Vdot]O2-HR function, and [Vdot]O2 thus calculated. A systematic comparison of the calculated [Vdot]O2 (c[Vdot]O2) with the actual measured [Vdot]O2 (m[Vdot]O2), showed that c[Vdot]O2 significantly overestimated the [Vdot]O2 during industrial work. The degree of overestimation was related to the type of work performed. The static muscular activity and the non-steady-state characteristics of the work were responsible for most of the overestimation A more reliable technique for estimating metabolic rate is to make simultaneous measurements of [Vdot]O2 and HR at different times during the work day and then from these recordings establish a function: [Vdot]O2=f(HR). Continuous HR recordings can then be used to ...

[1]  B. Saltin,et al.  Hemodynamic response to work with different muscle groups, sitting and supine. , 1967, Journal of applied physiology.

[2]  E. Asmussen,et al.  Determination of maximum working capacity at different ages in work with the legs or with the arms. , 1958, Scandinavian journal of clinical and laboratory investigation.

[3]  S Bevegård,et al.  Circulatory adaptation to arm and leg exercise in supine and sitting position. , 1966, Journal of applied physiology.

[4]  Å. Kilbom,et al.  Cardiovascular response to combined dynamic and static exercise. , 1981, Circulation research.

[5]  Changes in heart rate during exposure of the skin to radiant heat. , 1955 .

[6]  M H Harrison,et al.  The 'Oxylog': an evaluation. , 1982, Ergonomics.

[7]  P. Åstrand,et al.  Textbook of Work Physiology , 1970 .

[8]  E. Asmussen,et al.  Similarities and dissimilarities between static and dynamic exercise. , 1981, Circulation research.

[9]  D. Chaffin,et al.  Static work elements and selected circulatory responses. , 1980, American Industrial Hygiene Association journal.

[10]  J Malchaire,et al.  Validity of oxygen consumption measurement at the workplace: what are we measuring? , 1984, The Annals of occupational hygiene.

[11]  I. Åstrand Aerobic work capacity in men and women with special reference to age. , 1960, Acta physiologica Scandinavica. Supplementum.

[12]  H Monod,et al.  Effects of dynamic, static and combined work on heart rate and oxygen consumption. , 1979, Ergonomics.

[13]  R. Casaburi,et al.  Ventilatory and gas exchange dynamics in response to sinusoidal work. , 1977, Journal of applied physiology: respiratory, environmental and exercise physiology.

[14]  J. Barboriak,et al.  Effect of age on hemodynamic and metabolic response to static exercise. , 1974, Journal of applied physiology.

[15]  L BROUHA,et al.  DISCREPANCY BETWEEN HEART RATE AND OXYGEN CONSUMPTION DURING WORK IN THE WARMTH. , 1963, Journal of applied physiology.

[16]  B M Wright,et al.  A respirometer for use in the field for the measurement of oxygen consumption. 'The Miser', a miniature, indicating and sampling electronic respirometer. , 1978, Ergonomics.

[17]  R. Gilbert,et al.  Comparison of cardiovascular responses to steady- and unsteady-state exercise. , 1971, Journal of applied physiology.

[18]  D. DuBois,et al.  FIFTH PAPER THE MEASUREMENT OF THE SURFACE AREA OF MAN , 1915 .

[19]  J Rutenfranz,et al.  Occupationally induced stress, strain and peak loads as related to age. , 1980, Scandinavian journal of work, environment & health.

[20]  Phillips Ca,et al.  Cardiovascular responses to isometric neck muscle contractions: results after dynamic exercise with various headgear loading configurations. , 1984 .