Partial discharge and cross interference phenomena in a three-phase construction

This paper deals with partial discharge measurement and partial discharge characteristics on a three-phase construction. A simplified model of three-phase gas insulated switchgear is used in the experiment to simulate three-phase electric field in three-phase equipment. A particle was adhered on the different positions on the conductor and on the tank to produce partial discharge. Partial discharge signals flowing on three phase conductors were measured simultaneously with three high frequency current transformers clamped on the three- phase lines through capacitive voltage divider. Partial discharge signals induced on the enclosure were measured with the current transformer and the detecting impedance. The circuit was calibrated and examined by injecting known charges from a pulse calibrator to some points in the circuit. The calibration results indicate that measuring partial discharge signals only at the enclosure or on one of the phases of three phase construction will result in the position dependent sensitivity for partial discharges. Experimental results show that partial discharge inception voltages of a particle adhered on different position differed depended on the particle position. Phase of partial discharge inception voltage also depended on the particle position. Experimental results show that partial discharge caused by a particle on one phase conductor was induced and detected on the other phase conductors. Polarity and magnitude of discharge current flowing on each phase depended on the particle position. Each particle at different position generated discharge current which flowed on each phase so that the magnitude ratios of the currents flowing on each phase were unique for each particle. These results were discussed with considering electric field characteristic in three-phase construction and coupling capacitance between three-phase conductors and between the conductors and the tank.

[1]  Masayuki Hikita,et al.  Effects of Elliptical Nature of Rotating Electric Field on Partial Discharge Pattern in a Three-phase Construction , 2007 .

[2]  S. Shihab,et al.  Partial Discharge Measurement on Three-Core Belted Power Cables , 1989, IEEE Power Engineering Review.

[3]  Satoru Yanabu,et al.  Metallic Particle Motion in Three-phase SF6 Gas Insulated Bus , 1987 .

[4]  Satoru Yanabu,et al.  SF/sub 6/ insulation and its application to HV equipment , 1991 .

[5]  Robert G. Olsen,et al.  Corona onset as a design optimization criterion for high voltage hardware , 2000 .

[6]  R. Plath,et al.  Synchronous 3-Phase Partial Discharge Detection on Rotating Machines , 2005 .

[7]  P.A.A.F. Wouters,et al.  Fundamental aspects of excitation and propagation of on-line partial discharge signals in three-phase medium voltage cable systems , 2003 .

[8]  S. Yanabu,et al.  Metallic Particle Motion in 3-Phase SF6 Gas Insulated Bus , 1987, IEEE Transactions on Power Delivery.

[9]  G.V. Nagesh Kumar,et al.  Electric field effect on metallic particle contamination in a common enclosure gas insulated busduct , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  P.H.F. Morshuis,et al.  Partial discharges in 3-core belted power cables , 1989 .

[11]  H. Okubo,et al.  Metallic Particle Motion in 3-Phase SF6 Gas Insulated Bus , 1987, IEEE Power Engineering Review.

[12]  N. Malik,et al.  Calculation of Discharge Inception Voltages in SF6-N2 Mixtures , 1979, IEEE Transactions on Electrical Insulation.