Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines.

The advent of dynamic radiotherapy modeling and treatment techniques requires an infrastructure to weigh the merits of various interventions (breath holding, gating, tracking). The creation of treatment planning models that account for motion and deformation can allow the relative worth of such techniques to be evaluated. In order to develop a treatment planning model of a moving and deforming organ such as the lung, registration tools that account for deformation are required. We tested the accuracy of a mutual information based image registration tool using thin-plate splines driven by the selection of control points and iterative alignment according to a simplex algorithm. Eleven patients each had sequential CT scans at breath-held normal inhale and exhale states. The exhale right lung was segmented from CT and served as the reference model. For each patient, thirty control points were used to align the inhale CT right lung to the exhale CT right lung. Alignment accuracy (the standard deviation of the difference in the actual and predicted inhale position) was determined from locations of vascular and bronchial bifurcations, and found to be 1.7, 3.1, and 3.6 mm about the RL, AP, and IS directions. The alignment accuracy was significantly different from the amount of measured movement during breathing only in the AP and IS directions. The accuracy of alignment including thin-plate splines was more accurate than using affine transformations and the same iteration and scoring methodology. This technique shows promise for the future development of dynamic models of the lung for use in four-dimensional (4-D) treatment planning.

[1]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[2]  Nzhde Agazaryan,et al.  The effects of tumor motion on planning and delivery of respiratory-gated IMRT. , 2003, Medical physics.

[3]  Indrin J Chetty,et al.  A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study. , 2003, Medical physics.

[4]  Jürgen Weese,et al.  Landmark-based elastic registration using approximating thin-plate splines , 2001, IEEE Transactions on Medical Imaging.

[5]  J. Battista,et al.  Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance. , 2003, Medical physics.

[6]  D. Yan,et al.  Organ/patient geometric variation in external beam radiotherapy and its effects. , 2001, Medical physics.

[7]  D L McShan,et al.  Inclusion of organ deformation in dose calculations. , 2003, Medical physics.

[8]  Hyunjin Park,et al.  Method for quantifying volumetric lesion change in interval liver CT examinations , 2003, IEEE Transactions on Medical Imaging.

[9]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[10]  J. Wong,et al.  Estimating the dose variation in a volume of interest with explicit consideration of patient geometric variation. , 2000, Medical physics.

[11]  D. Peck,et al.  Registration and warping of magnetic resonance images to histological sections. , 1999, Medical physics.

[12]  C. Meyer,et al.  Automated generation of a four-dimensional model of the liver using warping and mutual information. , 2003, Medical physics.

[13]  P J Keall,et al.  A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error. , 2002, Physics in medicine and biology.

[14]  Gary E. Christensen,et al.  Consistent landmark and intensity-based image registration , 2002, IEEE Transactions on Medical Imaging.

[15]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[16]  M W Vannier,et al.  Image-based dose planning of intracavitary brachytherapy: registration of serial-imaging studies using deformable anatomic templates. , 2001, International journal of radiation oncology, biology, physics.

[17]  Steve B Jiang,et al.  Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. , 2003, Physics in medicine and biology.

[18]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .

[19]  David Atkinson,et al.  A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.

[20]  Charles R. Meyer,et al.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations , 1997, Medical Image Anal..

[21]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[22]  Jake Van Dyk,et al.  Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions. , 2003, Medical physics.

[23]  Max A. Viergever,et al.  Mutual-information-based registration of medical images: a survey , 2003, IEEE Transactions on Medical Imaging.

[24]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.