Disposable electrochemical flow cells for catalytic adsorptive stripping voltammetry (CAdSV) at a bismuth film electrode (BiFE)

Catalytic adsorptive stripping voltammetry (CAdSV) has been demonstrated at a bismuth film electrode (BiFE) in an injection-moulded electrochemical micro-flow cell. The polystyrene three-electrode flow cell was fabricated with electrodes moulded from a conducting grade of polystyrene containing 40% carbon fibre, one of which was precoated with Ag to enable its use as an on-chip Ag/AgCl reference electrode. CAdSV of Co(II) and Ni(II) in the presence of dimethylglyoxime (DMG) with nitrite employed as the catalyst was performed in order to assess the performance of the flow cell with an in-line plated BiFE. The injection-moulded electrodes were found to be suitable substrates for the formation of BiFEs. Key parameters such as the plating solution matrix, plating flow rate, analysis flow rate, solution composition and square-wave parameters have been characterised and optimal conditions selected for successful and rapid analysis of Co(II) and Ni(II) at the ppb level. The analytical response was linear over the range 1 to 20 ppb and deoxygenation of the sample solution was not required. The successful coupling of a microfluidic flow cell with a BiFE, thereby forming a “mercury-free” AdSV flow analysis sensor, shows promise for industrial and in-the-field applications where inexpensive, compact, and robust instrumentation capable of low-volume analysis is required.

[1]  Joseph Wang,et al.  Characterization and Applications of a Bismuth Bulk Electrode , 2004 .

[2]  E. Kirowa-Eisner,et al.  Determination of sub-μg l−1 concentrations of copper by anodic stripping voltammetry at the gold electrode , 1999 .

[3]  A. Economou,et al.  A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry , 2004 .

[4]  N. Goddard,et al.  A Study of the Determination of Cu(II) by Anodic Stripping Voltammetry on a Novel Nylon/Carbon Fiber Electrode , 2004 .

[5]  C. V. D. Berg,et al.  Simultaneous determination of several trace metals in seawater using cathodic stripping voltammetry with mixed ligands , 1997 .

[6]  Samo B. Hočevar,et al.  Bismuth film electrode for simultaneous adsorptive stripping analysis of trace cobalt and nickel using constant current chronopotentiometric and voltammetric protocol , 2003 .

[7]  Joseph Wang,et al.  Stripping voltammetry with the electrode material acting as a `built-in' internal standard , 2001 .

[8]  A. Bobrowski,et al.  Catalytic Systems in Adsorptive Stripping Voltammetry , 2000 .

[9]  Rashid O. Kadara,et al.  Stripping chronopotentiometric measurements of lead(II) and cadmium(II) in soils extracts and wastewaters using a bismuth film screen-printed electrode assembly , 2004, Analytical and bioanalytical chemistry.

[10]  A. Economou,et al.  On-line stripping voltammetry of trace metals at a flow-through bismuth-film electrode by means of a hybrid flow-injection/sequential-injection system. , 2007, Talanta.

[11]  R. Metelka,et al.  A Novelty in Potentiometric Stripping Analysis: Total Replacement of Mercury by Bismuth , 2002 .

[12]  M. Vega,et al.  Determination of cobalt in seawater by catalytic adsorptive cathodic stripping voltammetry. , 1997, Analytical chemistry.

[13]  Joseph Wang,et al.  Insights into the anodic stripping voltammetric behavior of bismuth film electrodes , 2001 .

[14]  R. R. Moore,et al.  Manganese detection in marine sediments: anodic vs. cathodic stripping voltammetry. , 2005, Talanta.

[15]  A. Economou,et al.  A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair. , 2003, Talanta.

[16]  Samuel P. Kounaves,et al.  Microfabricated Array of Iridium Microdisks as a Substrate for Direct Determination of Cu2+ or Hg2+ Using Square-Wave Anodic Stripping Voltammetry , 1999 .

[17]  Yuehe Lin,et al.  Catalytic adsorptive stripping determination of trace chromium (VI) at the bismuth film electrode. , 2004, Talanta.

[18]  Joseph Wang,et al.  A Study on Operational Parameters for Advanced Use of Bismuth Film Electrode in Anodic Stripping Voltammetry , 2002 .

[19]  E. Kirowa-Eisner,et al.  Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode , 2002 .

[20]  K. Vytras,et al.  Study on Catalytic Adsorptive Stripping Voltammetry of Trace Cobalt at Bismuth Film Electrodes , 2003 .

[21]  W. Heineman,et al.  Detection of secretion from pancreatic islets using chemically modified electrodes. , 2004, Analytical biochemistry.

[22]  R. Metelka,et al.  Carbon paste electrodes modified with Bi2O3 as sensors for the determination of Cd and Pb , 2002, Analytical and bioanalytical chemistry.

[23]  M. Smyth,et al.  Validation of bismuth film electrode for determination of cobalt and cadmium in soil extracts using ICP-MS. , 2004, Talanta.

[24]  G. Wittstock,et al.  Glucose oxidation at bismuth-modified platinum electrodes , 1998 .

[25]  John P. Hart,et al.  Screen-printed electrochemical sensors for monitoring metal pollutants , 2003 .

[26]  G. S. Walker,et al.  The Use of the Bismuth Film Electrode for the Anodic Stripping Voltammetric Determination of Tin , 2006 .

[27]  A. Królicka Bismuth-film-plated carbon paste electrodes , 2002 .

[28]  Joseph Wang,et al.  Bismuth‐Coated Screen‐Printed Electrodes for Stripping Voltammetric Measurements of Trace Lead , 2001 .

[29]  Yuehe Lin,et al.  Catalytic adsorptive stripping voltammetric measurements of trace vanadium at bismuth film electrodes. , 2006, Talanta.

[30]  A. Economou,et al.  Polymer-coated bismuth film electrodes for the determination of trace metals by sequential-injection analysis/anodic stripping voltammetry. , 2006, Analytica chimica acta.

[31]  A. Charalambous,et al.  A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry , 2005 .

[32]  P. Fielden,et al.  Applications, potentialities and limitations of adsorptive stripping analysis on mercury film electrodes , 1997 .

[33]  S. I. Parshakov,et al.  Small‐size sensors for the in‐field stripping voltammetric analysis of water , 2001 .

[34]  A. Bobrowski,et al.  Bismuth film electrode for adsorptive stripping voltammetry – electrochemical and microscopic study , 2004 .

[35]  M. Smyth,et al.  An introduction to bismuth film electrode for use in cathodic electrochemical detection , 2001 .

[36]  E. Kirowa-Eisner,et al.  Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes , 2002 .

[37]  A. Economou,et al.  Adsorptive Stripping Voltammetric Determination of Trace Uranium with a Bismuth‐Film Electrode Based on the U(VI)→U(V) Reduction Step of the Uranium‐Cupferron Complex , 2006 .

[38]  Anastasios Economou,et al.  Bismuth-film electrodes: recent developments and potentialities for electroanalysis , 2005 .

[39]  M. Smyth,et al.  Cathodic Electrochemical Detection of Nitrophenols at a Bismuth Film Electrode for Use in Flow Analysis , 2004 .

[40]  Huang-Hao Yang,et al.  Preparation of pH-sensitive polymer by thermal initiation polymerization and its application in fluorescence immunoassay. , 2005, Talanta.

[41]  Joseph Wang,et al.  Electrically Heated Bismuth-Film Electrode for Voltammetric Stripping Measurements of Trace Metals , 2002 .

[42]  Joseph Wang,et al.  Bismuth film electrodes for adsorptive stripping voltammetry of trace nickel , 2000 .

[43]  Yuehe Lin,et al.  Adsorptive stripping voltammetric measurements of trace uranium at the bismuth film electrode , 2005 .

[44]  Joseph Wang,et al.  Effect of Surface-Active Compounds on the Stripping Voltammetric Response of Bismuth Film Electrodes , 2001 .

[45]  A. Economou,et al.  Determination of trace aluminium by adsorptive stripping voltammetry on a preplated bismuth-film electrode in the presence of cupferron. , 2006, Talanta.

[46]  Z. Xue,et al.  Quantitative analysis of trace chromium in blood samples. Combination of the advanced oxidation process with catalytic adsorptive stripping voltammetry. , 2006, Analytical chemistry.

[47]  Lu,et al.  Bismuth-coated carbon electrodes for anodic stripping voltammetry , 2000, Analytical chemistry.

[48]  Joseph Wang,et al.  Adsorptive Stripping Voltammetric Measurements of Trace Molybdenum at the Bismuth Film Electrode , 2006 .

[49]  N. Jaffrezic‐Renault,et al.  Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes. , 2005, Talanta.

[50]  A. Economou,et al.  Trace Determination of Chromium by Square-Wave Adsorptive Stripping Voltammetry on Bismuth Film Electrodes , 2004 .

[51]  J. Strojek,et al.  Electrochemical and Microgravimetric Investigations of Lead, Cadmium and Copper Deposition and Stripping on Solid Electrodes , 2003 .

[52]  Joseph Wang,et al.  Potentiometric Stripping Analysis at Bismuth-Film Electrode , 2002 .

[53]  P R Fielden,et al.  Mercury film electrodes: developments, trends and potentialities for electroanalysis. , 2003, The Analyst.

[54]  Anastasios Economou,et al.  A study of Nafion-coated bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry. , 2004, The Analyst.

[55]  A. Economou,et al.  Simultaneous determination of nickel(II) and cobalt(II) by square wave adsorptive stripping voltammetry on a rotating-disc bismuth-film electrode , 2004 .