The Research on the Zero Sequence Circulating Current Suppression in Parallel Inverters

That inverters work in direct parallel would increase the reliability and capacity, and also reduce the cost and volume for tidal current generation system, but the zero sequence circulating current will be generated. The state model of the parallel connected inverters is constructed in synchronous rotating coordinates, the mechanism of circulating current is analyzed based on the state model, and a zero sequence circulating current suppression method is proposed. The zero sequence voltages of the inverters are regulated in real time to suppress the circulating current. The model of zero sequence circulating current closed-loop control is constructed, and the constraint of the method is analyzed. The experiment results show that the circulating current is suppressed effectively.

[1]  John E. Fletcher,et al.  Electrical issues associated with sea-water immersed windings in electrical generators for wave- and tidal current-driven power generation , 2009 .

[2]  Yu Zhang,et al.  The zero-sequence circulating currents between parallel three-phase inverters with three-pole transformers and reactors , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[3]  B. Fox,et al.  Impact of tidal generation on power system operation in Ireland , 2005, IEEE Transactions on Power Systems.

[4]  T.-P. Chen,et al.  Circulating zero-sequence current control of parallel three-phase inverters , 2006 .

[5]  Francesc Guinjoan,et al.  Interleaving Quasi-Sliding-Mode Control of Parallel-Connected Buck-Based Inverters , 2008, IEEE Transactions on Industrial Electronics.

[6]  Tsai-Fu Wu,et al.  Current Weighting Distribution Control Strategy for Multi-Inverter Systems to Achieve Current Sharing , 2007, IEEE Transactions on Power Electronics.

[7]  Jin-Woo Jung,et al.  Stability Analysis of Load Sharing Control for Distributed Generation Systems , 2007, IEEE Transactions on Energy Conversion.

[8]  Tsai-Fu Wu,et al.  Parallel-Inverter System With Failure Isolation and Hot-Swap Features , 2007, IEEE Transactions on Industry Applications.

[9]  Ching-Tsai Pan,et al.  Modeling and Control of Circulating Currents for Parallel Three-Phase Boost Rectifiers With Different Load Sharing , 2008, IEEE Transactions on Industrial Electronics.

[10]  Huan Yang,et al.  Study on Ideal Operation Status of Parallel Inverters , 2008, IEEE Transactions on Power Electronics.

[11]  Tsung-Po Chen Common-Mode Ripple Current Estimator for Parallel Three-Phase Inverters , 2007, 2007 IEEE Power Electronics Specialists Conference.

[12]  Tsung-Po Chen Dual-Modulator Compensation Technique for Parallel Inverters Using Space-Vector Modulation , 2009, IEEE Transactions on Industrial Electronics.

[13]  Zhang Feng Analysis of Circulating Current for Direct Parallel Grid-connected Inverters , 2009 .

[14]  Kay Soon Low,et al.  Model Predictive Control of Parallel-Connected Inverters for Uninterruptible Power Supplies , 2008, IEEE Transactions on Industrial Electronics.