Image-guided radiation therapy: emergence of MR-guided radiation treatment (MRgRT) systems

Radiation therapy has been on the march toward highly conformal and precise placement of radiation dose within the human body. Development of image-guidance systems based upon x-ray and ultrasound have advanced our capabilities to the level of a few millimeters of uncertainty in many sites. However, there are a subset of existing applications, and potentially many new applications that could be improved upon or pursued if greater targeting accuracy could be achieved. This is motivating the creation of magnetic resonance image-guided radiation treatment units (MRgRT) that either operate simultaneously or provide pre-treatment MR-based targeting capabilities. In this review, the motivation for these pursuits, an overview of recent developments, and a commentary on the challenges they face is presented.

[1]  K. Brock,et al.  Automated Weekly Online Replanning for IMRT of Cervix Cancer , 2008 .

[2]  J J W Lagendijk,et al.  Dose optimization for the MRI-accelerator: IMRT in the presence of a magnetic field , 2007, Physics in medicine and biology.

[3]  David A Jaffray,et al.  Suitability of radiochromic medium for real-time optical measurements of ionizing radiation dose. , 2005, Medical physics.

[4]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[5]  B. Fallone,et al.  First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system. , 2009, Medical physics.

[6]  B W Raaymakers,et al.  Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength , 2008, Physics in medicine and biology.

[7]  Installation of the 1.5 T MRI accelerator next to clinical accelerators: impact of the fringe field. , 2009, Physics in medicine and biology.

[8]  J. Lagendijk,et al.  Contour propagation in MRI-guided radiotherapy treatment of cervical cancer: the accuracy of rigid, non-rigid and semi-automatic registrations , 2009, Physics in medicine and biology.

[9]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[10]  L Xing,et al.  MRI-based Treatment Planning with Electron Density Information Mapped from CT Images: A Preliminary Study , 2008, Technology in cancer research & treatment.

[11]  D P Dearnaley,et al.  Radiotherapy planning of the pelvis using distortion corrected MR images: the removal of system distortions. , 2000, Physics in medicine and biology.

[12]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[13]  B G Fallone,et al.  Patient dosimetry for hybrid MRI-radiotherapy systems. , 2008, Medical physics.

[14]  Maria Hawkins,et al.  Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[15]  G. Glover,et al.  Mr geometric distortion correction for improved frame‐based stereotaxic target localization accuracy , 1995, Magnetic resonance in medicine.

[16]  Young-Bin Cho,et al.  Pelvic radiotherapy for cancer of the cervix: is what you plan actually what you deliver? , 2009, International journal of radiation oncology, biology, physics.

[17]  H. Romeijn,et al.  Comparative analysis of 60Co intensity-modulated radiation therapy. , 2008, Physics in medicine and biology.

[18]  B W Raaymakers,et al.  Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber , 2009, Physics in medicine and biology.

[19]  Gig S Mageras Introduction: management of target localization uncertainties in external-beam therapy. , 2005, Seminars in radiation oncology.

[20]  B. Fallone,et al.  Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems , 2010, Physics in medicine and biology.

[21]  J. Lagendijk,et al.  Online MRI guidance for healthy tissue sparing in patients with cervical cancer: an IMRT planning study. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  B Gino Fallone,et al.  A two-step scheme for distortion rectification of magnetic resonance images. , 2009, Medical physics.

[23]  M. Herk Errors and margins in radiotherapy. , 2004 .

[24]  Keith Wachowicz,et al.  Investigation of a 3D system distortion correction method for MR images , 2010, Journal of applied clinical medical physics.

[25]  B. Zackrisson,et al.  Dedicated magnetic resonance imaging in the radiotherapy clinic. , 2009, International journal of radiation oncology, biology, physics.

[26]  Marcel van Herk,et al.  Target definition in prostate, head, and neck. , 2005, Seminars in radiation oncology.

[27]  D. Jaffray,et al.  Advances in image-guided radiation therapy. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[28]  J G M Kok,et al.  Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept , 2009, Physics in medicine and biology.

[29]  Jan J W Lagendijk,et al.  MRI/linac integration. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  Richard Pötter,et al.  Aspects of MR Image Distortions in Radiotherapy Treatment Planning , 2001, Strahlentherapie und Onkologie.

[31]  David A Jaffray,et al.  Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. , 2007, International journal of radiation oncology, biology, physics.

[32]  C. N. Coleman,et al.  MRI-guided HDR prostate brachytherapy in standard 1.5T scanner. , 2004, International journal of radiation oncology, biology, physics.

[33]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[34]  A N T J Kotte,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field. , 2004, Physics in medicine and biology.

[35]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electrons , 2005, Physics in medicine and biology.

[36]  J Yorkston,et al.  Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. , 1992, Medical physics.

[37]  K Okajima,et al.  Development of an MR simulator: experimental verification of geometric distortion and clinical application. , 1996, Radiology.

[38]  B W Raaymakers,et al.  Experimental verification of magnetic field dose effects for the MRI-accelerator , 2007, Physics in medicine and biology.

[39]  H M Kooy,et al.  A software system for interventional magnetic resonance image-guided prostate brachytherapy. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[40]  B Gino Fallone,et al.  Characterization, prediction, and correction of geometric distortion in 3 T MR images. , 2007, Medical physics.

[41]  R. Kikinis,et al.  Superconducting open-configuration MR imaging system for image-guided therapy. , 1995, Radiology.

[42]  N. Pelc,et al.  Co‐registration of x‐ray and MR fields of view in a hybrid XMR system , 2005, Journal of magnetic resonance imaging : JMRI.

[43]  Dennis Mah,et al.  Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation. , 2002, Medical physics.

[44]  Partial boosting of prostate tumours: forward planned conformal radiotherapy vs. inverse planned intensity modulated radiotherapy? , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[45]  T. Mackie,et al.  Megavoltage CT on a tomotherapy system. , 1999, Physics in medicine and biology.

[46]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[47]  Tomas Kron,et al.  Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal , 2006, Journal of medical physics.

[48]  M. Uematsu,et al.  A dual computed tomography linear accelerator unit for stereotactic radiation therapy: a new approach without cranially fixated stereotactic frames. , 1996, International journal of radiation oncology, biology, physics.

[49]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[50]  David Jaffray,et al.  Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[51]  Kristy K Brock,et al.  Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. , 2005, International journal of radiation oncology, biology, physics.

[52]  H. Romeijn,et al.  Comparative analysis of 60Co intensity-modulated radiation therapy , 2008, Physics in medicine and biology.

[53]  B G Fallone,et al.  Radio frequency shielding for a linac-MRI system. , 2010, Physics in medicine and biology.

[54]  David A Jaffray,et al.  The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. , 2005, Medical physics.

[55]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field , 2007, Physics in medicine and biology.