A modified logarithmic mean enthalpy difference (LMED) method for evaluating the total heat transfer rate of a wet cooling coil under both unit and non-unit Lewis Factors

Abstract The logarithmic mean enthalpy difference, (LMED) method has been extensively used in evaluating the thermal performance of an air cooling coil under wet condition. The LMED method has been developed based on the assumption of unit Lewis Factor, i.e., Le 2/3  = 1. However, a number of previous studies have suggested that the Lewis Factor can actually deviate from being 1. Consequently, errors can be resulted in when calculating the total heat transfer rate of a wet cooling coil using the LMED method. Therefore, a modified LMED (m-LMED) method has been developed for calculating the total heat transfer rate under both unit and non-unit Lewis Factors and is reported in this paper. This m-LMED method has been validated by comparing its prediction of the total heat transfer rate to that from numerically solving the fundamental governing equations of heat and mass transfer of a wet cooling coil. The m-LMED method can therefore replace the LMED method for calculating the total heat transfer rate of a wet cooling coil under both unit and non-unit Lewis Factors.

[1]  P. L. Dhar,et al.  A new procedure for performance prediction of air conditioning coils , 1998 .

[2]  D. Didion,et al.  A simulation model of the transient performance of a heat pump , 1982 .

[3]  Jin Wen,et al.  A model for the dynamic response of a cooling coil , 2005 .

[4]  J. W. Ramsey,et al.  Thermal Environmental Engineering , 1970 .

[5]  Chi-Chuan Wang On the heat and mass analogy of fin-and-tube heat exchanger , 2008 .

[6]  Clark W. Bullard,et al.  Development and validation of a room air-conditioning simulation model , 1997 .

[7]  S. Theerakulpisut,et al.  Modeling cooling coils , 1998 .

[8]  S. Wongwises,et al.  Simultaneous heat and mass transfer characteristics for wavy fin-and-tube heat exchangers under dehumidifying conditions , 2006 .

[9]  P. G. Jolly,et al.  Distributed steady and dynamic modelling of dry-expansion evaporators , 1999 .

[10]  Anthony M. Jacobi,et al.  Air-side data interpretation and performance analysis for heat exchangers with simultaneous heat and mass transfer: Wet and frosted surfaces , 2005 .

[11]  R. Webb,et al.  Calculation of Fin Efficiency for Wet and Dry Fins , 1996 .

[12]  Eiji Hihara,et al.  Prediction of air coil performance under partially wet and totally wet cooling conditions using equivalent dry-bulb temperature method , 2002 .

[13]  K. Ogawa,et al.  Heat and Mass Transfer Performances on Plate Fin and Tube Heat Exchangers under Dehumidification , 1988 .

[14]  A. Jacobi,et al.  Low Reynolds number heat and mass transfer measurements of an overall counterflow, baffled, finned-tube, condensing heat exchanger , 1990 .

[15]  Somchai Wongwises,et al.  Finite circular fin method for heat and mass transfer characteristics for plain fin-and-tube heat exchangers under fully and partially wet surface conditions , 2007 .

[16]  Deng Shiming A dynamic mathematical model of a direct expansion (DX) water-cooled air-conditioning plant , 2000 .