Buckling of Built-Up Columns of Pultruded Fiber-Reinforced Polymer C-Sections

This paper presents the test results of an experimental investigation to evaluate the buckling behavior of built-up columns of pultruded profiles, subjected to axial compression. Specimens are assembled by using four (off the shelf) channel shaped profiles of E-glass fiber-reinforced polymer (FRP), having similar detailing to strut members in a large FRP structure that was executed in 2009 to start the restoration of the Santa Maria Paganica church in L’Aquila, Italy. This church had partially collapsed walls and no roof after the April 6, 2009, earthquake of 6.3 magnitude. A total of six columns are characterized with two different configurations for the bolted connections joining the channel sections into a built-up strut. Test results are discussed and a comparison is made with closed-form equation predictions for flexural buckling resistance, with buckling resistance values established from both eigenvalue and geometric nonlinear finite element analyses. Results show that there is a significant role played by the end loading condition, the composite action, and imperfections. Simple closed-form equations overestimate the flexural buckling strength, whereas the resistance provided by the nonlinear analysis provides a reasonably reliable numerical approach to establishing the actual buckling behavior.

[1]  Robert L. Yuan,et al.  Short vs. long column behavior of pultruded glass-fiber reinforced polymer composites , 2001 .

[2]  Edoardo Cosenza,et al.  Local buckling curves for the design of FRP profiles , 2000 .

[3]  L. Bank Composites for Construction: Structural Design with FRP Materials , 2006 .

[4]  Giosuè Boscato,et al.  Free Vibrations of Pultruded FRP Elements: Mechanical Characterization, Analysis, and Applications , 2009 .

[5]  Giosuè Boscato,et al.  Dynamic Response of a Sheet Pile of Fiber-Reinforced Polymer for Waterfront Barriers , 2011 .

[6]  J. T. Mottram,et al.  Physical testing for concentrically loaded columns of pultruded glass fibre reinforced plastic profile , 2003 .

[7]  Ever J. Barbero,et al.  Experimental verification of buckling-mode interaction in intermediate-length composite columns , 2000 .

[8]  J. Toby Mottram Does Performance Based Design with Fibre Reinforced Polymer Components and Structures provide any new Benefits and Challenges , 2011 .

[9]  Salvatore Russo Experimental and finite element analysis of a very large pultruded FRP structure subjected to free vibration , 2012 .

[10]  Shape Influence in Buckling of GFRP Pultruded Columns , 2003 .

[11]  Geoffrey Turvey,et al.  A computational and experimental analysis of the buckling, postbuckling and initial failure of pultruded GRP columns , 2006 .

[12]  J. T. Mottram Determination of critical load for flange buckling in concentrically loaded pultruded columns , 2004 .