Four-dimensional proton treatment planning for lung tumors.

PURPOSE In proton radiotherapy, respiration-induced variations in density lead to changes in radiologic path lengths and will possibly result in geometric misses. We compared different treatment planning strategies for lung tumors that compensate for respiratory motion. METHODS AND MATERIALS Particle-specific treatment planning margins were applied to standard helical computed tomography (CT) scans as well as to "representative" CT scans. Margins were incorporated beam specific laterally by aperture widening and longitudinally by compensator smearing. Furthermore, treatment plans using full time-resolved 4D-computed tomography data were generated. RESULTS Four-dimensional treatment planning guaranteed target coverage throughout a respiratory cycle. Use of a standard helical CT data set resulted in underdosing the target volume to 36% of the prescribed dose. For CT data representing average target positions, coverage can be expected but not guaranteed. In comparison to this strategy, 4D planning decreased the mean lung dose by up to 16% and the lung volume receiving 20 Gy (prescribed target dose 72 Gy) by up to 15%. CONCLUSION When the three planning strategies are compared, only 4D proton treatment planning guarantees delivery of the prescribed dose throughout a respiratory cycle. Furthermore, the 4D planning approach results in equal or reduced dose to critical structures; even the ipsilateral lung is spared.

[1]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[2]  J M Slater,et al.  Effects of proton and combined proton/photon beam radiation on pulmonary function in patients with resectable but medically inoperable non-small cell lung cancer. , 2001, Chest.

[3]  Daniel W. Miller,et al.  Hypofractionated proton beam radiotherapy for stage I lung cancer. , 2004, Chest.

[4]  M Goitein,et al.  A pencil beam algorithm for proton dose calculations. , 1996, Physics in medicine and biology.

[5]  H. Tsujii,et al.  Clinical results of fractionated proton therapy. , 1993, International journal of radiation oncology, biology, physics.

[6]  S. Webb,et al.  Comparison of proton therapy and conformal X-ray therapy in non-small cell lung cancer (NSCLC). , 1999, The British journal of radiology.

[7]  Radhe Mohan,et al.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. , 2005, Medical physics.

[8]  Daniel W. Miller,et al.  Methodologies and tools for proton beam design for lung tumors. , 2001, International journal of radiation oncology, biology, physics.

[9]  T. Bortfeld,et al.  The Use of Computers in Radiation Therapy , 2000, Springer Berlin Heidelberg.

[10]  E. Rietzel,et al.  Online compensation for target motion with scanned particle beams: simulation environment. , 2004, Physics in medicine and biology.

[11]  M. Wagner Automated range compensation for proton therapy. , 1982, Medical physics.

[12]  J. Slater,et al.  Pulmonary injury from proton and conventional radiotherapy as revealed by CT. , 1999, AJR. American journal of roentgenology.

[13]  R K Ten Haken,et al.  Estimation of tumor control probability model parameters from 3-D dose distributions of non-small cell lung cancer patients. , 1999, Lung cancer.

[14]  H. Satoh,et al.  Clinical evaluation of proton radiotherapy for non-small-cell lung cancer. , 2003, International journal of radiation oncology, biology, physics.

[15]  J M Slater,et al.  Proton-beam radiotherapy for early-stage lung cancer. , 1999, Chest.

[16]  Steve B. Jiang,et al.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates , 2005, Physics in medicine and biology.

[17]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[18]  R K Ten Haken,et al.  Radiation pneumonitis as a function of mean lung dose: an analysis of pooled data of 540 patients. , 1998, International journal of radiation oncology, biology, physics.

[19]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[20]  J. Fowler What can we expect from dose escalation using proton beams? , 2003, Clinical oncology (Royal College of Radiologists (Great Britain)).

[21]  Thomas Haberer,et al.  3D online compensation of target motion with scanned particle beam. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  H. Tsujii,et al.  Local control and recurrence of stage I non-small cell lung cancer after carbon ion radiotherapy. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.