Detection of rotor broken bar and eccentricity faults in induction motors via second order sliding mode observer

This paper provides a novel approach for detecting certain abnormal operating conditions in squirrel cage induction motors (SCIMs). A mathematical model of the faulty operating mode is derived with the rotor broken bars and the rotor eccentricity being the faults of interest. To detect the fault occurrence, an appropriate FDI observer, based on second order sliding modes, is presented and analyzed by Lyapunov methods. The ability of the suggested FDI observer to produce suitable residual signals which allow a reliable threshold-based fault detection is shown. Once the fault is detected, dedicated FFT analysis of the residuals allows the classification of the fault. The proposed scheme has been verified by real implementation tests using measurements taken from certain commercial three-phase SCIMs intentionally damaged in order to reproduce the fault scenarios of concern. Experimental results confirm the reliability of the suggested framework.

[1]  R. Puche-Panadero,et al.  Improved Resolution of the MCSA Method Via Hilbert Transform, Enabling the Diagnosis of Rotor Asymmetries at Very Low Slip , 2009, IEEE Transactions on Energy Conversion.

[2]  Austin H. Bonnett,et al.  Rotor Failures in Squirrel Cage Induction Motors , 1986, IEEE Transactions on Industry Applications.

[3]  Paul C. Krause,et al.  Simulation of Unsymmetrical 2-Phase Induction Machines , 1965 .

[4]  R. Marino,et al.  Adaptive input-output linearizing control of induction motors , 1993, IEEE Trans. Autom. Control..

[5]  Mohamed Benbouzid,et al.  A review of induction motors signature analysis as a medium for faults detection , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[6]  T. Floquet *,et al.  On the robust fault detection via a sliding mode disturbance observer , 2004 .

[7]  Leonid M. Fridman,et al.  High order sliding mode observer for linear systems with unbounded unknown inputs , 2010, Int. J. Control.

[8]  A. Levant Sliding order and sliding accuracy in sliding mode control , 1993 .

[9]  Alessandro Pisano,et al.  On-line adaptive clustering for process monitoring and fault detection , 2012, Expert Syst. Appl..

[10]  M. E. H. Benbouzid,et al.  What Stator Current Processing Based Technique to Use for Induction Motor Rotor Faults Diagnosis , 2002, IEEE Power Engineering Review.

[11]  A.H. Bonnett,et al.  Squirrel cage rotor options for AC induction motors , 2000, Conference Record of 2000 Annual Pulp and Paper Industry Technical Conference (Cat. No.00CH37111).

[12]  Silvio Simani,et al.  Model-based fault diagnosis in dynamic systems using identification techniques , 2003 .

[13]  Paul C. Krause,et al.  Simulation of Symmetrical Induction Machinery , 1965 .

[14]  Alessandro Pisano,et al.  Robust FDI in induction motors via second order sliding mode technique , 2012, 2012 12th International Workshop on Variable Structure Systems.

[15]  Dong-Seok Hyun,et al.  Direct Torque Control of induction motor with reduction of torque ripple , 2000, 2000 26th Annual Conference of the IEEE Industrial Electronics Society. IECON 2000. 2000 IEEE International Conference on Industrial Electronics, Control and Instrumentation. 21st Century Technologies.

[16]  Alessandro Pisano,et al.  Second-order sliding mode approaches to disturbance estimation and fault detection in fractional-order systems , 2011 .

[17]  Leonid M. Fridman,et al.  High-order sliding-mode observation and fault detection , 2007, 2007 46th IEEE Conference on Decision and Control.

[18]  Alessandro Pisano,et al.  Oscillation shaping in uncertain linear plants with nonlinear PI control: analysis and experimental results , 2012 .

[19]  G. B. Kliman,et al.  Noninvasive detection of broken rotor bars in operating induction motors , 1988 .

[20]  Alessandro Pisano,et al.  Finite-time converging jump observer for switched linear systems with unknown inputs ☆ , 2011 .

[21]  Alessandro Pisano,et al.  Switched Observers for Switched Linear Systems With Unknown Inputs , 2011, IEEE Transactions on Automatic Control.

[22]  A. Craciunescu,et al.  A comparison of various strategies for direct torque control of induction motors , 2007, 2007 International Aegean Conference on Electrical Machines and Power Electronics.

[23]  W. T. Thomson,et al.  Current signature analysis to detect induction motor faults , 2001 .

[24]  H. Razik,et al.  Fault detection of broken rotor bars in induction motor using a global fault index , 2006, IEEE Transactions on Industry Applications.

[25]  Alessandro Pisano,et al.  Sliding mode control: A survey with applications in math , 2011, Math. Comput. Simul..

[26]  Alessandro Pisano,et al.  Fault diagnosis for the vertical three-tank system via high-order sliding-mode observation , 2010, J. Frankl. Inst..