A magneto-acoustic method for the noninvasive measurement of bioelectric currents

A method for the noninvasive measurement of low-level ionically conducted electric currents flowing in electrolytes and tissue is investigated. Experiments show that the application of oscillating magnetic fields to current-carrying media will cause focal Lorentz forces which generate detectable vibrations. These vibrations can be sensitively and noninvasively detected by surface contact detectors and can be used to determine the magnitude of internal current flows. Microampere-level currents introduced in hamsters to simulate natural bioelectric currents have been sensitively detected by this approach.<<ETX>>

[1]  R. Forster Measurement of gastrointestinal blood flow by means of gas absorption. , 1967, Gastroenterology.

[2]  J. Steinbach,et al.  Electric pacing of intact and transected canine small intestine and its computer model. , 1975, The American journal of physiology.

[3]  R. Hobson,et al.  Prediction of intestinal viability using Doppler ultrasound technics. , 1975, American journal of surgery.

[4]  C. Chou Relationship between intestinal blood flow and motility. , 1982, Annual review of physiology.

[5]  J. W. Vanable,et al.  Bioelectricity and Regeneration , 1979 .

[6]  A. Hreno,et al.  Effect of acute ischemia on the motility of the small bowel in the awake dog. , 1975, European surgical research. Europaische chirurgische Forschung. Recherches chirurgicales europeennes.

[7]  L. Carey,et al.  Determination of viability of ischemic intestine by Doppler ultrasound. , 1978, Surgery.

[8]  J. Semmlow,et al.  Quantitative myoelectric determination of bowel viability. , 1986, The Journal of surgical research.

[9]  S. B. Brummer,et al.  Electrochemical Considerations for Safe Electrical Stimulation of the Nervous System with Platinum Electrodes , 1977, IEEE Transactions on Biomedical Engineering.

[10]  S. Katz,et al.  New parameters of viability in ischemic bowel disease. , 1974, American journal of surgery.

[11]  W. Shoemaker,et al.  The use of surface oximetry to assess bowel viability. , 1984, Archives of surgery.

[12]  Hemantha K. Wickramasinghe,et al.  Atomic force microscope–force mapping and profiling on a sub 100‐Å scale , 1987 .

[13]  S Kohatsu,et al.  The effects of ischemia on the electrical and contractile activities of the canine small intestine. , 1978, American journal of surgery.

[14]  D. Silverman,et al.  Monitoring tissue elimination of fluorescein with the perfusion fluorometer: a new method to assess capillary blood flow. , 1981, Surgery.