An Active Diagnostic System for Structural Health Monitoring of Rocket Engines

An active diagnostic system using built-in piezoelectric actuator/sensor networks was developed for monitoring crack growth in a rocket engine pipe. The diagnostic system combines a sensor network, portable diagnostic hardware and data analysis software which allows for real-time in situ monitoring and long term tracking of the structural integrity of pressure vessels. Experimental data shows that the system can detect a surface crack as small as 4 mm and a through-crack as small as 2 mm in the high pressure engine pipe made of Inconel 718. It was found that the actuator-sensor paths that are most sensitive to crack growth are the ones in which the crack is growing away from, rather than towards the path. This discovery will provide important guidelines for the design of a sensor network for crack detection. It was also observed that the bending mode (equivalent to the A0 mode in plates) is more sensitive than the longitudinal mode (equivalent to the S0 mode in plates) to crack growth.

[1]  H. Lamb On waves in an elastic plate , 1917 .

[2]  I. A. Viktorov Rayleigh and Lamb Waves , 1967 .

[3]  P. Cawley,et al.  The interaction of Lamb waves with defects , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  S. Beard,et al.  Active Damage Detection in Filament Wound Composite Tubes Using Built-In Sensors and Actuators , 1997 .

[5]  D. R. Komar,et al.  Reusable Rocket Engine Operability Modeling and Analysis , 1998 .

[6]  Hegeon Kwun,et al.  Long-range guided wave inspection of pipe using magnetostrictive sensor technology: the feasibility of defect characterization , 1998, Smart Structures.

[7]  M. Lowe,et al.  The Mode Conversion of a Guided Wave by a Part-Circumferential Notch in a Pipe , 1998 .

[8]  Z. Chang,et al.  Scattering of Lamb waves from a rivet hole with edge cracks , 1999 .

[9]  Tribikram Kundu,et al.  A New Sensor for Pipe Inspection by Lamb Waves , 2000 .

[10]  Xinlin Qing,et al.  SMART Layer and SMART Suitcase for structural health monitoring applications , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[11]  Constantinos Soutis,et al.  Structural Health Monitoring in Composite Materials Using Lamb Wave Methods , 2001 .

[12]  Constantinos Soutis,et al.  Damage detection in composite materials using lamb wave methods , 2002 .

[13]  Victor Giurgiutiu,et al.  Piezoelectric Wafer Embedded Active Sensors for Aging Aircraft Structural Health Monitoring , 2002 .

[14]  Joseph L. Rose,et al.  Guided Wave Resonance Tuning for Pipe Inspection , 2002 .

[15]  Hoon Sohn,et al.  Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward , 2003 .

[16]  F. Chang,et al.  Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: I. Diagnostics , 2004 .

[17]  Chang Zhang,et al.  A hybrid piezoelectric/fiber optic diagnostic system for structural health monitoring , 2005 .