New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis

Phantom equivalents of different human anatomical parts are routinely used for imaging system evaluation or dose calculations. The various recommendations on the generic phantom structure given by organizations such as the AAPM, are not always accurate when evaluating a very specific task. When we compared the AAPM head phantom containing 3 mm of aluminum to actual neuro-endovascular image guided interventions (neuro-EIGI) occurring in the Circle of Willis, we found that the system automatic exposure rate control (AERC) significantly underestimated the x-ray parameter selection. To build a more accurate phantom for neuro-EIGI, we reevaluated the amount of aluminum which must be included in the phantom. Human skulls were imaged at different angles, using various angiographic exposures, at kV's relevant to neuro-angiography. An aluminum step wedge was also imaged under identical conditions, and a correlation between the gray values of the imaged skulls and those of the aluminum step thicknesses was established. The average equivalent aluminum thickness for the skull samples for frontal projections in the Circle of Willis region was found to be about 13 mm. The results showed no significant changes in the average equivalent aluminum thickness with kV or mAs variation. When a uniform phantom using 13 mm aluminum and 15 cm acrylic was compared with an anthropomorphic head phantom the x-ray parameters selected by the AERC system were practically identical. These new findings indicate that for this specific task, the amount of aluminum included in the head equivalent must be increased substantially from 3 mm to a value of 13 mm.

[1]  R J Jennings,et al.  A patient-equivalent attenuation phantom for estimating patient exposures from automatic exposure controlled x-ray examinations of the abdomen and lumbo-sacral spine. , 1990, Medical physics.

[2]  S. Balter,et al.  A new tool for benchmarking cardiovascular fluoroscopes , 2001, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  K. Hoffmann,et al.  Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system. , 2005, Medical physics.

[4]  C. M. Langton,et al.  Development and Evaluation of a Phantom for Morphometric X-ray Absorptiometry , 1999, Osteoporosis International.

[5]  Stephen Rudin,et al.  Region-of-interest micro-angiographic fluoroscope detector used in aneurysm and artery stenosis diagnoses and treatment , 2012, Medical Imaging.

[6]  Stephen Rudin,et al.  Use of the Microangiographic Fluoroscope for Coiling of Intracranial Aneurysms , 2011, Neurosurgery.

[7]  W E Bolch,et al.  Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology. , 2003, Medical physics.

[8]  G. Blake,et al.  Development of a phantom for morphometric X-ray absorptiometry. , 2001, The British journal of radiology.

[9]  C Keleshis,et al.  Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions , 2009, Medical Imaging.

[10]  C. Bergamini,et al.  Comparison of six phantoms for entrance skin dose evaluation in 11 standard X‐ray examinations , 2005, Journal of applied clinical medical physics.