Acute and Long‐Term Ventricular Stimulation Thresholds with a New, Iridium Oxide‐Coated Electrode

Efforts have been made to design electrodes that significantly reduce not only the acute and chronic stimulation thresholds, but also attenuate the early peaking phenomenon and polarization. At two voltage levels (2.7 V and 5.4 V, respectively), we evaluated the right ventricular stimulation thresholds obtained with a new, iridium oxide‐coated electrode in ten patients who received a VVI pacemaker. Measurements were mode at implant and at multiple intervals for 1 year. Pulse width stimulation thresholds at implant were as follow: 0.04 ± 0.008 msec at 2.7 V, 0.03 ± 0.004 msec at 5.4 V; values at 2 weeks were 0.14 ± 0.06 msec at 2.7 V, 0.07 ± 0.025 msec at 5.4 V; values at 3 months were 0.09 ± 0.03 msec at 2.7 V, 0.05 ± 0.01 msec at 5.4 V; values at 1 year were 0.08 ± 0.02 msec at 2.7 V, 0.04 ± 0.01 msec at 5.4 V, The maximal increase of 0.11 ± 0.05 msec occurred at 2.7 V, 2 weeks after implant. Our results indicate that this new electrode provides low acute and long‐term stimulation thresholds, as well as an attenuated early peaking phenomenon, being able to stimulate safely at 2.7 V even early after implant.

[1]  W. IRNICH Der Einfluß der Elektrodengröße auf die Reizschwelle bei der Schrittmacherreizung , 1969 .

[2]  H. Mond,et al.  The Porous Titanium Steroid Eluting Electrode: A Double Blind Study Assessing the Stimulation Threshold Effects of Steroid , 1988, Pacing and clinical electrophysiology : PACE.

[3]  J. Allen,et al.  Chronic Animal Testing of New Cardiac Pacing Electrodes , 1990, Pacing and clinical electrophysiology : PACE.

[4]  P. Gillette,et al.  Long‐Term Follow‐up of Pulse Width Threshold of Transvenous and Myo‐epicardial Leads , 1984, Pacing and clinical electrophysiology : PACE.

[5]  J. Mugica,et al.  Electrode‐Heart Interface: Definition of the Ideal Electrode , 1983, Pacing and clinical electrophysiology : PACE.

[6]  S S Barold,et al.  Stimulation and sensing thresholds for cardiac pacing: electrophysiologic and technical aspects. , 1981, Progress in cardiovascular diseases.

[7]  I. Starke Long-term follow up of cardiac pacing threshold using a noninvasive method of measurement. , 1978, British heart journal.

[8]  E. Rolett,et al.  Short‐Term Threshold Behavior of Human Ventricular Pacing Electrodes: Noninvasive Monitoring with a Multiprogrammable Pacing System , 1981, Pacing and clinical electrophysiology : PACE.

[9]  Lois S. Robblee,et al.  Charge Injection Properties of Thermally-Prepared Iridium Oxide Films , 1985 .

[10]  An Evaluation of Long‐term Stimulation Thresholds by Measurement of Chronic Strength Duration Curves , 1981 .

[11]  S. Merigliano,et al.  The iridium/iridium oxide electrode for in vivo measurement of oesophageal and gastric pH. , 1984, Journal of medical engineering & technology.

[12]  A N Zimmerman,et al.  Acute voltage, charge, and energy thresholds as functions of electrode size for electrical stimulation of the canine heart. , 1979, Cardiovascular research.

[13]  N. Smyth,et al.  The significance of electrode surface area and stimulating thresholds in permanent cardiac pacing. , 1976, Journal of Thoracic and Cardiovascular Surgery.

[14]  H. Mond,et al.  The High Impedance Dish Electrode—Clinical Experience with a New Tined Lead , 1982, Pacing and clinical electrophysiology : PACE.

[15]  H. Fischler Polarization Properties of Small‐Surface‐Area Pacemaker Electrodes—Implications on Reliability of Sensing arid Pacing * , 1979, Pacing and clinical electrophysiology : PACE.

[16]  S Furman,et al.  Cardiac pacing and pacemakers IV. Threshold of cardiac stimulation. , 1977, American heart journal.

[17]  L. Padeletti,et al.  Preliminary Experience with the pH‐triggered Pacemaker , 1978, Pacing and clinical electrophysiology : PACE.

[18]  P. Bergveld,et al.  Comparison of electrode impedances of Pt, PtIr (10% Ir) and Ir-AIROF electrodes used in electrophysiological experiments , 2006, Medical and Biological Engineering and Computing.

[19]  Y. Sato Characterization of thermally oxidized iridium oxide films , 1990 .

[20]  J. Brinker,et al.  Time Course of Transvenous Pacemaker Stimulation Impedance, Capture Threshold, and Electrogram Amplitude , 1986, Pacing and clinical electrophysiology : PACE.

[21]  V Parsonnet,et al.  Characteristics of Intracardiac Electrograms * , 1978, Pacing and clinical electrophysiology : PACE.

[22]  S. Furman,et al.  Threshold behavior of electrodes in long-term ventricular pacing. , 1977, The American journal of cardiology.

[23]  D C Amundson,et al.  The Porous Endocardial Electrode , 1979, Pacing and clinical electrophysiology : PACE.

[24]  S. Furman,et al.  Clinical thresholds of endocardial cardiac stimulation: a long-term study. , 1975, The Journal of surgical research.

[25]  A. Maseri,et al.  Tissue reaction to intracavitary electrodes: effect on duration and efficiency of unipolar pacing in patients with A-V block. , 1973, The Journal of cardiovascular surgery.