Formaldehyde (CH2O) emissions from particleboard underlayment have been measured in 0.17 and 0.2 m3 chambers at separate laboratories to test the comparability of small scale environmental chamber measurements under different ventilation and product loading conditions. Absolute CH2O calibration was established through intermethod comparison of different monitoring techniques against a CH2O generation apparatus. Interlaboratory precision was enhanced via co-calibration of each laboratory’s CH2O colorimetric analyzer against the same blank and bi-level generation source at the beginning and end of the study. The results show excellent intermethod and interlaboratory agreement in both the CH2O calibration and particleboard emissions testing. The CH2O emission rates of the test specimens demonstrate a Fick’s Law dependence on CH2O vapor concentration. Measured CH2O concentrations are described by a single-compartment, single emitter model, and are inversely proportional to the ratio [N/L (m/h)] of the air exc...
[1]
S. Tejada,et al.
Evaluation of silica gel cartridges coated in situ with acidified 2,4-dinitrophenylhydrazine for sampling aldehydes and ketones in air.
,
1986,
International journal of environmental analytical chemistry.
[2]
T. Matthews,et al.
Surface emission monitoring of pressed-wood products containing urea-formaldehyde resins
,
1986
.
[3]
T. Matthews.
Evaluation of a modified CEA Instruments, Inc. model 555 analyzer for the monitoring of formaldehyde vapor in domestic environments
,
1982
.
[4]
T. Howell,et al.
Evaluation of selected monitoring methods for formaldehyde in domestic environments
,
1982
.