Compact x-ray microtomography system for element mapping and absorption imaging.

We have designed and built a compact x-ray microtomography system to perform element mapping and absorption imaging by exploiting scanning fluorescence tomography and full-field transmission microtomography, respectively. It is based on a low power microfocus tube and is potentially appropriate for x-ray diagnostics in space. Full-field transmission tomography yields the three-dimensional inner structure of an object. Fluorescence microtomography provides the element distribution on a virtual section through the sample. Both techniques can be combined for appropriate samples. Microradiography as well as fluorescence mapping are also possible. For fluorescence microtomography a small and intensive microbeam is required. It is generated using a polycapillary optic. Operating the microfocus tube with a molybdenum target at 12 W, a microbeam with a full width at half maximum lateral extension of 16 microm and a flux of about 10(8) photonss is generated. As an example of application, this beam is used to determine the element distribution inside dried plant samples. For full-field scanning tomography, the x-ray optic is removed and the sample is imaged in magnifying projection onto a two-dimensional position sensitive detector. Depending on the sample size, a spatial resolution down to about 10 microm is possible in this mode. The method is demonstrated by three-dimensional imaging of a rat humerus.

[1]  V. G. Kohn,et al.  Phase-contrast microtomography with coherent high-energy synchrotron x rays , 1996 .

[2]  U. Bonse,et al.  3D computed X-ray tomography of human cancellous bone at 8 microns spatial and 10(-4) energy resolution. , 1994, Bone and mineral.

[3]  Jiunn‐Tzong Wu,et al.  Can fog contribute to the nutrition of Chamaecyparis obtusa var. formosana? Uptake of a fog solute tracer into foliage and transport to roots. , 2007, Tree physiology.

[4]  Anatoly Snigirev,et al.  Nanotomography based on hard x-ray microscopy with refractive lenses , 2002 .

[5]  Anatoly Snigirev,et al.  High-Resolution 3D Imaging Microscopy Using Hard X-Rays , 2004 .

[6]  Christian G. Schroer,et al.  Mapping the local nanostructure inside a specimen by tomographic small-angle x-ray scattering , 2006 .

[7]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[8]  J. C. Elliott,et al.  X‐ray microtomography , 1982, Journal of microscopy.

[9]  T. C. Miller,et al.  High-throughput screening with micro-x-ray fluorescence , 2005 .

[10]  Dean R. Haeffner,et al.  Mapping the chemical states of an element inside a sample using tomographic x-ray absorption spectroscopy , 2003 .

[11]  U. Cowgill,et al.  The Culturing and Testing of Two Species of Duckweed , 1989 .

[12]  U. Bonse,et al.  Multiple-beam X-ray interferometry for phase-contrast microtomography. , 2001, Journal of synchrotron radiation.

[13]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[14]  A. Sasov Microtomography. I: Methods and equipment , 1987 .

[15]  J. Pearson,et al.  Aquatic Toxicology and Hazard Assessment , 1982 .

[16]  Sasov,et al.  Desktop X‐ray microscopy and microtomography , 1998, Journal of microscopy.

[17]  S. Goldstein,et al.  The direct examination of three‐dimensional bone architecture in vitro by computed tomography , 1989, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[18]  M. Chukalina,et al.  High-resolution X-ray fluorescence microtomography of homogeneous samples , 2000 .

[19]  Birgit Kanngießer,et al.  Three-dimensional micro-XRF investigations of paint layers with a tabletop setup , 2005 .

[20]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[21]  Ian Foster,et al.  A high-throughput x-ray microtomography system at the Advanced , 2001 .

[22]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[23]  L. Lemelle,et al.  Nondestructive three-dimensional elemental microanalysis by combined helical x-ray microtomographies , 2004 .

[24]  S. McGrath,et al.  Cadmium accumulation in populations of Thlaspi caerulescens and Thlaspi goesingense , 2000 .

[25]  H Weinans,et al.  Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data. , 2004, Bone.

[26]  C. Schroer Reconstructing x-ray fluorescence microtomograms , 2001 .

[27]  Alexander Sasov X-ray microtomography of plastics and composite materials , 2002, Optics + Photonics.

[28]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .