Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs.

PURPOSE A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. METHODS Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. RESULTS The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4 +/- 1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. CONCLUSIONS The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

[1]  Jan J W Lagendijk,et al.  Intrafraction motion of the prostate during external-beam radiation therapy: analysis of 427 patients with implanted fiducial markers. , 2007, International journal of radiation oncology, biology, physics.

[2]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[3]  Lei Dong,et al.  Intrafraction prostate motion during IMRT for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[4]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[5]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[6]  Serge J. Belongie,et al.  Automatic co-registration of volumetric images based on implanted fiducial markers , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[7]  Lei Xing,et al.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging. , 2008, Medical physics.

[8]  Thomas O. Binford,et al.  Depth from Edge and Intensity Based Stereo , 1981, IJCAI.

[9]  Marco van Vulpen,et al.  Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  Ross Berbeco,et al.  Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification. , 2009, Medical physics.

[11]  Paul Suetens,et al.  Minimal Shape and Intensity Cost Path Segmentation , 2007, IEEE Transactions on Medical Imaging.

[12]  Dieter Seghers Local Graph-Based Probabilistic Representation of Object Shape and Appearance for Model-Based Medical Image Segmentation (Lokale graafgebaseerde probabilistische representatie van beeldobjecten voor modelgebaseerde segmentatie van medische beelden) , 2008 .

[13]  Luca Incrocci,et al.  Stereographic targeting in prostate radiotherapy: speed and precision by daily automatic positioning corrections using kilovoltage/megavoltage image pairs. , 2008, International journal of radiation oncology, biology, physics.

[14]  P Hofman,et al.  Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK). , 2000, International journal of radiation oncology, biology, physics.

[15]  Jean Pouliot,et al.  (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device. , 2003, International journal of radiation oncology, biology, physics.

[16]  Patrick A Kupelian,et al.  Influence of intrafraction motion on margins for prostate radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[17]  Emma J Harris,et al.  Feasibility of fully automated detection of fiducial markers implanted into the prostate using electronic portal imaging: a comparison of methods. , 2006, International journal of radiation oncology, biology, physics.

[18]  K L Lam,et al.  Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.

[19]  Henry M Kuerer,et al.  Locoregional treatment outcomes for inoperable anthracycline-resistant breast cancer. , 2002, International journal of radiation oncology, biology, physics.

[20]  Timothy Solberg,et al.  Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[21]  R. Mohan,et al.  On the use of EPID-based implanted marker tracking for 4D radiotherapy. , 2004, Medical physics.

[22]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[23]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[24]  Steve B. Jiang,et al.  Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking , 2007, Physics in medicine and biology.

[25]  Weihua Mao,et al.  Combined kV and MV imaging for real-time tracking of implanted fiducial markers. , 2008, Medical physics.

[26]  J Pouliot,et al.  Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID. , 2003, Medical physics.

[27]  F Nüsslin,et al.  Potential and limitations of the automatic detection of fiducial markers using an amorphous silicon flat-panel imager. , 2003, Physics in medicine and biology.

[28]  F. V. Heuvel,et al.  Image enhancement techniques allowing observation of intra-fractional motion in IMRT treatment for prostate carcinoma , 2009 .

[29]  Frank Van den Heuvel,et al.  Clinical application of a repositioning scheme, using gold markers and electronic portal imaging. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  Takeo Kanade,et al.  Stereo by Intra- and Inter-Scanline Search Using Dynamic Programming , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.