Floating-Gate MOS Transistor with Dynamic Biasing as a Radiation Sensor

This paper describes the possibility of using an Electrically Programmable Analog Device (EPAD) as a gamma radiation sensor. Zero-biased EPAD has the lowest fading and the highest sensitivity in the 300 Gy dose range. Dynamic bias of the control gate during irradiation was presented for the first time; this method achieved higher sensitivity compared to static-biased EPADs and better linear dependence. Due to the degradation of the transfer characteristics of EPAD during irradiation, a function of the safe operation area has been found that determines the maximum voltage at the control gate for the desired dose, which will not lead to degradation of the transistor. Using an energy band diagram, it was explained why the zero-biased EPAD has higher sensitivity than the static-biased EPAD.

[1]  A. Jaksic,et al.  Temperature effects and long term fading of implanted and unimplanted gate oxide RADFETs , 2004, IEEE Transactions on Nuclear Science.

[2]  S. Djorić-Veljković,et al.  Negative bias temperature instability in n-channel power VDMOSFETs , 2008, Microelectron. Reliab..

[3]  A. Mathewson,et al.  Dose rate dependence of RADFET irradiation and post-irradiation responses , 2004, 2004 24th International Conference on Microelectronics (IEEE Cat. No.04TH8716).

[4]  R. Bose The development of an in-vivo dosimeter for the application in radiotherapy , 2012 .

[6]  C. M. M. Paschoal,et al.  A Novel Dosimetry System for Computed Tomography using Phototransistor , 2011 .

[7]  F. Wrobel,et al.  Floating Gate Dosimeter Suitability for Accelerator-Like Environments , 2017, IEEE Transactions on Nuclear Science.

[8]  Evaluation of commercial programmable floating gate devices as radiation dosimeters , 2009 .

[9]  W. B. Knowlton,et al.  An Interactive Simulation Tool for Complex Multilayer Dielectric Devices , 2011, IEEE Transactions on Device and Materials Reliability.

[10]  S. Ristic,et al.  Feasibility study of a current mode gamma radiation dosimeter based on a commercial pin photodiode and a custom made auto-ranging electrometer , 2013 .

[11]  Pablo Escobedo,et al.  Light-Dependent Resistors as Dosimetric Sensors in Radiotherapy , 2020, Sensors.

[12]  J. Kahilainen,et al.  The Direct Ion Storage Dosemeter , 1996 .

[13]  W. J. Meyer,et al.  Dual dielectric silicon metal-oxide-semiconductor field-effect transistors as radiation sensors , 1989 .

[14]  J. Barak,et al.  Temperature effects and long term fading of implanted and un-implanted gate oxide RADFETs , 2003, Proceedings of the 7th European Conference on Radiation and Its Effects on Components and Systems, 2003. RADECS 2003..

[15]  V. Mathur Ion storage dosimetry , 2001 .

[16]  Luigi Dilillo,et al.  Design of a radiation tolerant system for total ionizing dose monitoring using floating gate and RadFET dosimeters , 2016 .

[17]  Ninoslav Stojadinovic,et al.  The contribution of border traps to the threshold voltage shift in pMOS dosimetric transistors , 1995 .

[18]  Ivica Manic,et al.  NBTI and Irradiation Effects in P-Channel Power VDMOS Transistors , 2016, IEEE Transactions on Nuclear Science.

[19]  Luca Larcher,et al.  Floating Gate Devices: Operation and Compact Modeling , 2004, Springer US.

[20]  M. Pejovic,et al.  P‐channel metal–oxide–semiconductor dosimeter fading dependencies on gate bias and oxide thickness , 1995 .

[21]  A. Jaksic,et al.  The behavior of fixed and switching oxide traps of RADFETs during irradiation up to high absorbed doses. , 2015, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[22]  T. A. Dellin,et al.  Radiation response of floating gate EEPROM memory cells , 1989 .

[23]  W. B. Knowlton,et al.  Stacked dual-oxide MOS energy band diagram visual representation program (IRW student paper) , 2006, IEEE Transactions on Device and Materials Reliability.

[24]  Stephen D. Gaalema,et al.  Silicon pin diode array hybrids for charged particle detection , 1989 .

[25]  Goran S. Ristić,et al.  SENSITIVITY AND FADING OF PMOS DOSIMETERS WITH THICK GATE OXIDE , 1995 .

[26]  Radiation dosimeter based on floating gate MOS transistor , 1991 .

[27]  Alessandro Masi,et al.  Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters , 2019, IEEE Transactions on Nuclear Science.

[28]  Andrew Holmes-Siedle,et al.  The space-charge dosimeter: General principles of a new method of radiation detection , 1974 .

[29]  R. Duane,et al.  FET-based radiation sensors with Er 2 O 3 gate dielectric , 2018, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms.

[30]  Goran S. Ristić,et al.  A new microcontroller-based RADFET dosimeter reader , 2012 .

[31]  Goran S. Ristić,et al.  Influence of ionizing radiation and hot carrier injection on metal-oxide-semiconductor transistors , 2008 .

[32]  Marko Andjelkovic,et al.  Current mode response of phototransistors to gamma radiation , 2015 .

[33]  I. Thomson,et al.  A floating gate MOSFET dosimeter requiring no external bias supply , 1997 .