Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions

The aim of this study was to analyse the trends of the first three power spectral moments of the mechanomyogram (MMG) signal recorded by a microphone (MMGMIC) and an accelerometer (MMGACC) during sustained contractions. MMG signals were recorded from the biceps brachii muscle in 14 healthy male subjects during a 3 min isometric elbow flexion at 30% of the maximal voluntary contraction. MMG absolute and normalised root mean square (RMS), mean power frequency (MNF), power spectral variance (Mc2), and skewness (μ3) were computed. For both MMGMIC and MMGACC, absolute and normalised RMS and Mc2 increased while MNF and μ3 decreased with contraction time (P<0.001). The rates of change of RMS over time were significantly correlated (P<0.001) for MMGMIC and MMGACC but not correlated for spectral moments. The coefficient of variation of RMS was higher for MMGMIC than for MMGACC, while the opposite was observed for μ3 (P<0.05). It was concluded that higher order spectral moments of the MMG signal change during sustained contraction, indicating a complex modification of the shape of the power spectrum and not just scaling of the bandwidth. This is most likely due to the additional motor unit recruitment with fatigue and to the non-linear summation of motor unit contributions to the signal. Moreover, the characteristics of MMG signals recorded with microphones and accelerometers have important differences, which should be taken into account when comparing results from different studies.

[1]  Anna Jaskólska,et al.  The effect of skinfold on frequency of human muscle mechanomyogram. , 2004, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[2]  B. Maton,et al.  The fatigability of two agonistic muscles in human isometric voluntary submaximal contraction: an EMG study , 2004, European Journal of Applied Physiology and Occupational Physiology.

[3]  R. Merletti,et al.  Estimation of shape characteristics of surface muscle signal spectra from time domain data , 1995, IEEE Transactions on Biomedical Engineering.

[4]  J. Dowling,et al.  The relationship between voluntary electromyogram, endurance time and intensity of effort in isometric handgrip exercise , 1995, European Journal of Applied Physiology and Occupational Physiology.

[5]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[6]  P Madeleine,et al.  Evidence of long term muscle fatigue following prolonged intermittent contractions based on mechano- and electromyograms. , 2003, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[7]  C. Orizio,et al.  Surface mechanomyogram reflects muscle fibres twitches summation. , 1996, Journal of biomechanics.

[8]  B. Bigland-ritchie,et al.  Fatigue of intermittent submaximal voluntary contractions: central and peripheral factors. , 1986, Journal of applied physiology.

[9]  Dario Farina,et al.  Upper trapezius muscle mechanomyographic and electromyographic activity in humans during low force fatiguing and non-fatiguing contractions , 2002, European Journal of Applied Physiology.

[10]  D T Barry,et al.  Acoustic signals from frog skeletal muscle. , 1987, Biophysical journal.

[11]  Claudio Orizio,et al.  Influence of motor units recruitment and firing rate on the soundmyogram and EMG characteristics in cat gastrocnemius. , 1992, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  B. Maton,et al.  The fatigability of two agonistic muscles in human isometric voluntary submaximal contraction: an EMG study , 2004, European Journal of Applied Physiology and Occupational Physiology.

[13]  G. Sjøgaard,et al.  Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode , 2002, European Journal of Applied Physiology.

[14]  T Moritani,et al.  The muscle sound properties of different muscle fiber types during voluntary and electrically induced contractions. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[15]  M. Watakabe,et al.  Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions , 2003, Medical and Biological Engineering and Computing.

[16]  R. Merletti,et al.  Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles , 2006, Medical and Biological Engineering and Computing.

[17]  Katsumi Mita,et al.  Time-frequency analysis of mechanomyogram during sustained contractions with muscle fatigue , 2004 .

[18]  P Madeleine,et al.  Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions. , 2001, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[19]  T. McMahon,et al.  The mechanism of low-frequency sound production in muscle. , 1987, Biophysical journal.

[20]  Knaflitz,et al.  Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions. , 1990, Journal of applied physiology.

[21]  C. Orizio Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. , 1993, Critical reviews in biomedical engineering.

[22]  M Solomonow,et al.  Force and surface mechanomyogram relationship in cat gastrocnemius. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[23]  M. Watakabe,et al.  Mechanical behaviour of condenser microphone in mechanomyography , 2001, Medical and Biological Engineering and Computing.

[24]  C. J. Luca Myoelectrical manifestations of localized muscular fatigue in humans. , 1984 .