Immobilization and voltammetric detection of human interleukine-2 gene on the pencil graphite electrode.

The immobilization and differential pulse anodic voltammetry (DPAV) of a 20-mer oligonucleotide related to the human interleukine-2 (hIL-2) using renewable pencil graphite electrode (PGE) is described. The influences of electrochemical pretreatment of PGE on the ability of the electrode in hIL-2 adsorption, and conditions of hiIL-2 immobilization on PGE including immobilization potential and time, sodium chloride concentration as well as stirring of the solution were studied and optimum conditions were suggested. Accordingly, the electrochemical pretreatment of the polished PGE by electrostatic procedure at 1.80V for 5min in 0.50M acetate buffer solution of pH 4.8 is proposed as the optimum pre-treatment procedure. Similarly, the obtained optimum conditions for immobilization of hIL-2 on the activated PGE was an immobilization duration of 5min at applied potential of 0.50V. Trace levels of hIL-2 was readily detected following only 5min immobilization period with detection limit of 6nM.

[1]  D. Regier,et al.  Design, synthesis and expression of a human interleukin-2 gene incorporating the codon usage bias found in highly expressed Escherichia coli genes. , 1988, Nucleic acids research.

[2]  Jan Tavernier,et al.  Molecular cloning of human interleukin 2 cDNA and its expression in E. coli , 1983, Nucleic Acids Res..

[3]  Erwin K. Kastrup,et al.  Drug facts and comparisons , 1977 .

[4]  J. Rothel,et al.  Expression of ovine interleukin-2 cDNA in Escherichia coli. , 1997, Veterinary immunology and immunopathology.

[5]  Huangxian Ju,et al.  Rapid detection of ssDNA and RNA using multi-walled carbon nanotubes modified screen-printed carbon electrode. , 2005, Biosensors & bioelectronics.

[6]  Kagan Kerman,et al.  Indicator‐Free Electrochemical DNA Biosensor Based on Adenine and Guanine Signals , 2002 .

[7]  Ronen Polsky,et al.  Genomagnetic electrochemical assays of DNA hybridization. , 2002, Talanta.

[8]  L T Kubota,et al.  Polishable and renewable DNA hybridization biosensors. , 1998, Analytical chemistry.

[9]  M. Hejazi,et al.  Developing an electrochemical deoxyribonucleic acid (DNA) biosensor on the basis of human interleukine-2 gene using an electroactive label. , 2006, Analytica chimica acta.

[10]  Xianting Zeng,et al.  Electrochemical biosensing of DNA with capture probe covalently immobilized onto glassy carbon surface , 2005 .

[11]  Marco Mascini,et al.  Electrochemical DNA biosensor for the detection of TT and Hepatitis B virus from PCR amplified real samples by using methylene blue. , 2002, Talanta.

[12]  A. Erdem,et al.  Rigid carbon composites: a new transducing material for label-free electrochemical genosensing , 2004 .

[13]  Gustavo Rivas,et al.  Indicator-free electrochemical DNA hybridization biosensor , 1998 .

[14]  Buffhirko VET , 2006 .

[15]  Shengshui Hu,et al.  Direct electrochemistry of DNA, guanine and adenine at a nanostructured film-modified electrode , 2003, Analytical and bioanalytical chemistry.

[16]  R. Kizek,et al.  DNA hybridization at microbeads with cathodic stripping voltammetric detection. , 2002, Talanta.

[17]  W. Heineman,et al.  Laboratory techniques in electroanalytical chemistry , 1984 .

[18]  Joseph Wang,et al.  Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization. , 2003, The Analyst.

[19]  Peter E. Nielsen,et al.  Reduction and Oxidation of Peptide Nucleic Acid and DNA at Mercury and Carbon Electrodes , 1999 .

[20]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[21]  C. Schulze,et al.  Solid composite electrodes for DNA enrichment and detection. , 2002, Talanta.

[22]  Kiheung Kim,et al.  Ko Kuei Chen: a pioneer of modern pharmacological research in China , 2022, Protein & cell.

[23]  G. Rivas,et al.  Immobilization of DNA on glassy carbon electrodes for the development of affinity biosensors. , 2003, Biosensors & bioelectronics.

[24]  Kagan Kerman,et al.  Allele-specific genotype detection of factor V Leiden mutation from polymerase chain reaction amplicons based on label-free electrochemical genosensor. , 2002, Analytical chemistry.

[25]  R. Kizek,et al.  Voltammetry of two single-stranded isomeric end-labeled -SH deoxyoligonucleotides on mercury electrodes. , 2002, Talanta.

[26]  E. Ferapontova,et al.  Direct electrochemical oxidation of DNA on polycrystalline gold electrodes , 2003 .

[27]  H. Katinger,et al.  Generation of an Influenza A Virus Vector Expressing Biologically Active Human Interleukin-2 from the NS Gene Segment , 2005, Journal of Virology.

[28]  Slobodan V. Jovanovic,et al.  How Easily Oxidizable Is DNA? One-Electron Reduction Potentials of Adenosine and Guanosine Radicals in Aqueous Solution , 1997 .

[29]  Reduction of guanosine at a mercury electrode , 1989 .

[30]  H. Thorp,et al.  Modification of indium tin oxide electrodes with repeat polynucleotides: electrochemical detection of trinucleotide repeat expansion. , 2001, Analytical chemistry.

[31]  J Wang,et al.  Magnetic bead-based label-free electrochemical detection of DNA hybridization. , 2001, The Analyst.

[32]  R. Engstrom Electrochemical pretreatment of glassy carbon electrodes , 1982 .

[33]  Yan Lin,et al.  Expression of an interleukin-6 - interleukin-2 fusion protein (pIL-6-IL-2) in P. pastoris. , 2004, European cytokine network.

[34]  Joseph Wang,et al.  Pencil-based renewable biosensor for label-free electrochemical detection of DNA hybridization , 2001 .