Ultrasound Imaging during Endovascular Abdominal Aortic Aneurysm Repair Using the Stentor Bifurcated Endograft

Purpose: To evaluate different ultrasound modalities during implantation and follow-up of endovascular grafts for abdominal aortic aneurysm (AAA) exclusion. Methods: Between February 1995 and May 1996, 18 patients (14 men; aged 49 to 80 years, mean 67) were treated with endovascular intervention for infrarenal AAA. Seventeen patients received Mialhe Stentor bifurcated grafts, while one patient was treated with a straight graft for pseudoaneurysm. During and after the implantation, 3.25- and 5-MHz annular array ultrasound probes were used for transabdominal visualization of the endograft. Intravascular ultrasound was applied in combination with angiography for postoperative control. Results: Intraprocedurally, transabdominal two-dimensional (2D) ultrasound successfully monitored guidewire passage from the groin into the main part of the bifurcated endograft for implantation of the second limb. All implantation procedures were technically successful, but four endoleaks were identified intraprocedurally by 2D ultrasound and angiography. One healed spontaneously, two were treated with endovascular techniques at 1 and 4 months, and the last leak was scheduled for repair when the patient died of probable myocardial infarction at 2 months. During follow-up, 2D ultrasound successfully visualized all the endografts; no endoleaks were found in up to 18 months of surveillance. Conclusions: Transabdominal ultrasound imaging could be valuable in bifurcated endograft deployment both for guiding guidewire insertion and for controlling wire position before the second graft limb is connected to the main graft. Provided that satisfactory visualization of the entire endograft can be obtained, ultrasound examination may possibly replace arteriography and computed tomographic scanning as a follow-up investigation.

[1]  G. Kopchok,et al.  Preliminary clinical outcome and imaging criterion for endovascular prosthesis development in high-risk patients who have aortoiliac and traumatic arterial lesions. , 1996, Journal of vascular surgery.

[2]  M. Thompson,et al.  Late failure of endoluminal abdominal aortic aneurysm repair due to continued aneurysm expansion , 1996, The British journal of surgery.

[3]  A. Nasim,et al.  Endovascular repair of abdominal aortic aneurysm: An initial experience , 1996, The British journal of surgery.

[4]  Staal Hatlinghus,et al.  Endovaskulær behandling av abdominale aortaaneurismer , 1996 .

[5]  J. May,et al.  Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms. , 1996, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[6]  Edward B. Diethrich,et al.  The clinical value of three-dimensional intravascular ultrasound imaging. , 1995 .

[7]  G. White,et al.  Early Experience with the Sydney and EVT Prostheses for Endoluminal Treatment of Abdominal Aortic Aneurysms , 1995, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[8]  M. Horrocks,et al.  Endovascular repair of aortic aneurysm , 1995, The British journal of surgery.

[9]  W. Moore The role of endovascular grafting technique in the treatment of infrarenal abdominal aortic aneurysm. , 1995, Cardiovascular surgery.

[10]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.

[11]  C Düber,et al.  Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. , 1996, Radiology.

[12]  N L Volodos,et al.  Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and the abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. , 1991, VASA. Supplementum.