Sub-synchronous interaction in wind power plants — part I: Study tools and techniques

This is the first part of a two-paper series which investigates different modeling and simulation tools and techniques appropriate for the analysis of sub-synchronous control and torsional interaction in wind power plants. A critical review of the commonly used techniques is presented which allows identifying the three suitable candidates. These methods include frequency scanning method, the test signal method for the calculation of electrical damping provided by the wind turbine generator, and electromagnetic transient analysis which confirms the veracity of the first two methods. A dynamic frequency scanning method for the turbine side is developed which takes account of the turbine non-linearities and its active behavior. It is shown that these three tools allow capturing all the information pertinent to sub-synchronous interaction phenomena. The application of these tools and techniques on a practical power system comprising type 3 wind turbines and series compensated lines is demonstrated. Results obtained from these three methodologies are consistent and complimentary.

[1]  A. Yazdani,et al.  Modeling and Stability Analysis of a DFIG-Based Wind-Power Generator Interfaced With a Series-Compensated Line , 2009, IEEE Transactions on Power Delivery.

[2]  Aniruddha M. Gole,et al.  A frequency scanning method for the identification of harmonic instabilities in HVDC systems , 1995 .

[3]  R.G. Farmer,et al.  Use of Frequency Scanning Techniques for Subsynchronous Resonance Analysis , 1979, IEEE Transactions on Power Apparatus and Systems.

[4]  Yunzhi Cheng,et al.  Voltage-profile-based approach for developing collection system aggregated models for wind generation resources for grid voltage ride-through studies , 2011 .

[5]  Neville R. Watson,et al.  Power System Harmonic Analysis: Arrillaga/Power System Harmonic Analysis , 1997 .

[6]  L Harnefors,et al.  Proof and Application of the Positive-Net-Damping Stability Criterion , 2011, IEEE Transactions on Power Systems.

[7]  Bikash C. Pal,et al.  Modal Analysis of Grid-Connected Doubly Fed Induction Generators , 2007 .

[8]  Lingling Fan,et al.  Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network , 2011, IEEE Transactions on Energy Conversion.

[9]  D. Muthumuni,et al.  Advanced screening techniques for Sub-Synchronous Interaction in wind farms , 2012, PES T&D 2012.

[10]  Hans-Peter Nee,et al.  Frequency-domain modelling of sub-synchronous torsional interaction of synchronous machines and a high voltage direct current transmission link with line-commutated converters , 2010 .

[11]  Aniruddha M. Gole,et al.  Steady state frequency response of STATCOM , 2001 .

[12]  D.G. Ramey,et al.  Simplified transmission and generation system analysis procedures for subsynchronous resonance problems , 1977, IEEE Transactions on Power Apparatus and Systems.

[13]  M. Sahni,et al.  Sub-synchronous interaction in Wind Power Plants- part II: An ercot case study , 2012, 2012 IEEE Power and Energy Society General Meeting.

[14]  L. Harnefors,et al.  Analysis of Subsynchronous Torsional Interaction With Power Electronic Converters , 2007, IEEE Transactions on Power Systems.

[15]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[16]  Lingling Fan,et al.  Modeling of DFIG-Based Wind Farms for SSR Analysis , 2010, IEEE Transactions on Power Delivery.

[17]  Hans-Peter Nee,et al.  A Comparison of Different Frequency Scanning Methods for Study of Subsynchronous Resonance , 2011, IEEE Transactions on Power Systems.

[18]  R.G. Farmer,et al.  Navajo project report on subsynchronous resonance analysis and solutions , 1977, IEEE Transactions on Power Apparatus and Systems.

[19]  F. Mei,et al.  Modal Analysis of Grid-Connected Doubly Fed Induction Generators , 2006, IEEE Transactions on Energy Conversion.

[20]  Garth D. Irwin,et al.  Sub-synchronous control interactions between type 3 wind turbines and series compensated AC transmission systems , 2011, 2011 IEEE Power and Energy Society General Meeting.