Dynamic shimming for multi‐slice magnetic resonance imaging

Dynamic shimming has been implemented in three pulse sequences on a commercial GE Signa 1.5‐T imaging system. Multi‐slice field maps are acquired before the imaging sequence, and linear shim terms and center frequencies are calculated for each slice. During the imaging scan, the linear shim terms and center frequency are set before each pulse sequence repetition according to the current slice. Acquisition of multi‐slice field maps and calculation of shim terms and center frequency for each slice are accomplished in a matter of seconds. Pulse sequences require only minimal modification to add dynamic shimming capability. Results are shown for a fat saturation spin‐echo sequence, a single‐shot echo‐planar gradient‐recalled echo sequence, and a spiral acquisition gradient‐recalled echo sequence. In all cases, dynamic shimming with shim currents and center frequency optimized for each slice is shown to give better results than constant shim currents and a single center frequency optimized for the entire volume of interest.

[1]  A M Blamire,et al.  Dynamic shim updating: A new approach towards optimized whole brain shimming , 1996, Magnetic resonance in medicine.

[2]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[3]  J. Michael Fitzpatrick,et al.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities , 1992, IEEE Trans. Medical Imaging.

[4]  P G Webb,et al.  Automated single‐voxel proton MRS: Technical development and multisite verification , 1994, Magnetic resonance in medicine.

[5]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[6]  Henry Stark,et al.  Spiral Sampling in Magnetic Resonance Imaging-The Effect of Inhomogeneities , 1987, IEEE Transactions on Medical Imaging.

[7]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[8]  E. Jackson,et al.  Unsuppressed fat in the right anterior diaphragmatic region on fat‐suppressed T2‐weighted fast spin‐echo MR images , 1995, Journal of magnetic resonance imaging : JMRI.

[9]  R Proksa,et al.  Automatic shimming for localized spectroscopy. , 1988, Medical physics.

[10]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[11]  B Wood,et al.  A simple field map for shimming , 1987, Magnetic resonance in medicine.

[12]  A. Maeda,et al.  Reconstruction by weighted correlation for MRI with time-varying gradients. , 1988, IEEE transactions on medical imaging.

[13]  L. Budinsky,et al.  Simulation of the influence of magnetic field inhomogeneity and distortion correction in MR imaging. , 1990, Magnetic resonance imaging.

[14]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[15]  Ching-Ming Lai Reconstructing NMR images under magnetic fields with large inhomogeneities , 1982 .

[16]  W. Hanafee,et al.  Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck. , 1992, AJNR. American journal of neuroradiology.

[17]  D G Nishimura,et al.  Inhomogeneity correction using an estimated linear field map , 1996, Magnetic resonance in medicine.

[18]  M A Moerland,et al.  Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging. , 1992, Magnetic resonance imaging.

[19]  Manfred G Prammer,et al.  A new approach to automatic shimming , 1988 .

[20]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[21]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[22]  H. W. Park,et al.  Fast gradient‐echo chemical‐shift imaging , 1988, Magnetic resonance in medicine.

[23]  K. Sekihara,et al.  Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging. , 1984, Physics in medicine and biology.

[24]  Douglas C. Noll,et al.  Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[25]  K. Sekihara,et al.  NMR Imaging for Magnets with Large Nonuniformities , 1985, IEEE Transactions on Medical Imaging.

[26]  K Sekihara,et al.  Image restoration from nonuniform static field influence in modified echo-planar imaging. , 1987, Medical physics.

[27]  G. Marchal,et al.  On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgery. , 1994, Magnetic resonance imaging.

[28]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[29]  E. Feig,et al.  Magnetic resonance imaging with non-uniform fields , 1986 .

[30]  Gary H. Glover,et al.  Phase unwrapping of MR phase images using Poisson equation , 1995, IEEE Trans. Image Process..