User-defined constant switching frequency current control strategy for a four-leg inverter

A novel current control strategy called user-defined constant switching frequency method for a four-leg voltage source inverter is presented. This scheme allows the user to directly set the switching frequency of all the legs. Unlike the hysteresis current control where the switching frequency is variable and the fourth leg operates at a very high frequency, the proposed method ensures a constant and reduced switching frequency for all the switches of the inverter. This is achieved by exercising an indirect control on the occurrence and duration of the uncontrollable (zero vector) states. The three legs of the inverter are operated in hysteresis current tracking mode and the switches of the fourth leg are controlled with a square pulse of fixed user-defined frequency. The above advantages supplemented with the simplicity, fast response and robustness make this an attractive scheme. The feasibility of the proposed strategy is verified through extensive simulation and experimental studies on a distribution static compensator to compensate for unbalanced and non-linear loads in a distribution power network.

[1]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[2]  B. Bose An adaptive hysteresis-band current control technique of a voltage-fed PWM inverter for machine drive system , 1990 .

[3]  Arindam Ghosh,et al.  Unified shunt compensator algorithm based on generalised instantaneous reactive power theory , 2001 .

[4]  Liuchen Chang,et al.  A novel DSP-based current-controlled PWM strategy for single phase grid connected inverters , 2006, IEEE Transactions on Power Electronics.

[5]  Joachim Holtz Pulsewidth modulation-a survey , 1992, IEEE Trans. Ind. Electron..

[6]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[7]  Dushan Boroyevich,et al.  Three-dimensional space vector modulation for four-leg voltage-source converters , 2002 .

[8]  Ting-Yu Chang,et al.  An improved hysteresis current controller for reducing switching frequency , 1994 .

[9]  R. Portillo,et al.  Three-dimensional space vector modulation in abc coordinates for four-leg voltage source converters , 2003, IEEE Power Electronics Letters.

[10]  Muhammad H. Rashid,et al.  New current control scheme for PWM inverters , 1988 .

[11]  Paolo Tenti,et al.  A novel hysteresis control method for current-controlled voltage-source PWM inverters with constant modulation frequency , 1990 .

[12]  S. B. Dewan,et al.  Analysis of a PWM AC to DC voltage source converter under the predicted current control with a fixed switching frequency , 1991 .

[13]  Donald W. Novotny,et al.  Current Control of VSI-PWM Inverters , 1985, IEEE Transactions on Industry Applications.

[14]  T. S. Radwan,et al.  Analysis of current controllers for voltage-source inverter , 1997, IEEE Trans. Ind. Electron..

[15]  Baolin Zhang,et al.  A novel hysteresis current control for active power filter with constant frequency , 2004 .

[16]  Paolo Mattavelli,et al.  Comparison of current control techniques for active filter applications , 1998, IEEE Trans. Ind. Electron..

[17]  Peter W. Lehn,et al.  Fixed-frequency space-vector-modulation control for three-phase four-leg active power filters , 2002 .

[18]  Paolo Mattavelli,et al.  High-performance hysteresis modulation technique for active filters , 1997 .

[19]  Fangrui Liu,et al.  A Novel Variable Hysteresis Band Current Control of Three-Phase Three-Level Unity PF Rectifier With Constant Switching Frequency , 2006, IEEE Transactions on Power Electronics.

[20]  Bong-Hwan Kwon,et al.  A novel SVM-based hysteresis current controller , 1998 .

[21]  Arindam Ghosh,et al.  A new approach to load balancing and power factor correction in power distribution system , 2000 .