The 'Augmented' Circles: A Video-Guided Solution for the Down-the-Beam Positioning of IM Nail Holes

Intramedullary nailing is the surgical procedure mostly used in fracture reduction of the tibial and femoral shafts. Following successful insertion of the nail into the medullary canal, it must be fixed by inserting screws through its proximal and distal locking holes. Prior to distal locking of the nail, surgeons must position the C-arm device and patient leg in such a way that the nail holes appear as circles in the X-ray image. This is considered a ‘trial and error’ process, is time consuming and requires many X-ray shots. We propose an augmented reality application that visually depicts to the surgeon two ‘augmented’ circles, their centers lying on the axis of the nail hole, making it visible in space. After an initial X-ray image acquisition, real-time video guidance allows the surgeon to superimpose the ‘augmented’ circles by moving the patient leg; the result being nail holes appearing as circles. Our nail pose recovery was evaluated on 1000 random trials and we consistently recovered the nail angulation within 2.76 ± 1.66°. Lastly, in a preclinical experiment involving 7 clinicians, we demonstrated that in over 95% of the trials, the nail hole appeared as a circle using an initial X-ray image.

[1]  Christian Krettek,et al.  Robot-assisted Long Bone Fracture Reduction , 2009, Int. J. Robotics Res..

[2]  Lejing Wang,et al.  Radiation-Free Drill Guidance in Interlocking of Intramedullary Nails , 2012, MICCAI.

[3]  Tien-Kan Chung,et al.  An electromagnetic-induction approach for screw-hole targeting in interlocking-nail surgery , 2012, 2012 IEEE Sensors.

[4]  Saso Tomazic,et al.  Angle Estimation of Simultaneous Orthogonal Rotations from 3D Gyroscope Measurements , 2011, Sensors.

[5]  Hervé Delingette,et al.  Medical Image Computing and Computer-Assisted Intervention – MICCAI 2012 , 2012, Lecture Notes in Computer Science.

[6]  Musa Citak,et al.  Assessment of the accuracy of infrared and electromagnetic navigation using an industrial robot: Which factors are influencing the accuracy of navigation? , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  Guoyan Zheng,et al.  Accurate and reliable pose recovery of distal locking holes in computer-assisted intra-medullary nailing of femoral shaft fractures: A preliminary study , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[8]  R Geoff Richards,et al.  Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking , 2012, BMC Musculoskeletal Disorders.

[9]  Nassir Navab,et al.  Camera Augmented Mobile C-Arm (CAMC): Calibration, Accuracy Study, and Clinical Applications , 2010, IEEE Transactions on Medical Imaging.

[10]  Nadine Warzée,et al.  A Novel Technique for Distal Locking of Intramedullary Nail Based on Two Non-constrained Fluoroscopic Images and Navigation , 2008, IEEE Transactions on Medical Imaging.