Ultraviolet lighting during orthopaedic surgery and the rate of infection.

BACKGROUND Ultraviolet lighting is an alternative to laminar airflow in the operating room that may be as effective for lowering the number of environmental bacteria and possibly lowering infection rates by killing the bacteria rather than simply reducing the number at the operative site. The purpose of the present study was to compare the infection rates following joint replacement procedures performed by one orthopaedic surgeon with and without the use of ultraviolet lighting. METHODS From July 1986 to July 2005, one surgeon performed 5980 total joint replacements at one facility. In September 1991, ultraviolet lighting was installed in the operating rooms. All procedures that were performed before the installation of the ultraviolet lighting utilized horizontal laminar airflow, whereas all procedures that were performed after that date utilized ultraviolet lighting without laminar airflow. Factors associated with the rate of infection were analyzed. RESULTS Over a nineteen-year period, forty-seven infections occurred following 5980 joint replacements. The infection rate without ultraviolet lighting (and with laminar airflow) was 1.77%, and the infection rate with ultraviolet lighting was 0.57% (p < 0.0001). The odds of infection were 3.1 times greater for procedures performed without ultraviolet lighting (and with laminar airflow) as compared with those performed with only ultraviolet lighting (p < 0.0001). The infection rate associated with total hip replacement decreased from 1.03% to 0.72% (p = 0.5407), and the infection rate associated with total knee replacement decreased from 2.20% to 0.50% (p < 0.0001). Revision surgery, previous infection, age, total body mass index, use of cement, disease, and diagnosis were not associated with an elevated infection rate. CONCLUSION When appropriate safety precautions are taken, ultraviolet lighting appears to be an effective way to lower the risk of infection in the operating room during total joint replacement surgery.

[1]  U Persson,et al.  Ultraviolet radiation and ultra-clean air enclosures in operating rooms. UV-protection, economy, and comfort. , 1992, The Journal of arthroplasty.

[2]  M. Ritter,et al.  The surgeon's garb. , 1980, Clinical orthopaedics and related research.

[3]  O M Lidwell,et al.  Ultraviolet radiation and the control of airborne contamination in the operating room. , 1994, The Journal of hospital infection.

[4]  G. J. Taylor,et al.  Wound disinfection with ultraviolet radiation. , 1995, The Journal of hospital infection.

[5]  B. Allen,et al.  Ultraviolet light in orthopedic operating rooms at Duke University. Thirty-five years' experience, 1937-1973. , 1973, Clinical orthopaedics and related research.

[6]  A. Joshi,et al.  Outcome in patients lost to follow-up. , 2003, The Journal of arthroplasty.

[7]  R. Blowers,et al.  Infection and sepsis after operations for total hip or knee-joint replacement: influence of ultraclean air, prophylactic antibiotics and other factors , 1984, Journal of Hygiene.

[8]  F. Bérard,et al.  POSTOPERATIVE WOUND INFECTIONS: THE INFLUENCE OF ULTRAVIOLET IRRADIATION OF THE OPERATING ROOM AND OF VARIOUS OTHER FACTORS. , 1964, Annals of surgery.

[9]  L. Lindberg,et al.  Systemic antibiotics and gentamicin-containing bone cement in the prophylaxis of postoperative infections in total hip arthroplasty. , 1981, Clinical orthopaedics and related research.

[10]  D. McCollum,et al.  Wound infections in patients undergoing total hip arthroplasty. Ultraviolet light for the control of airborne bacteria. , 1979, Archives of surgery.

[11]  P. D. Wilson,et al.  Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system. , 1982, The Journal of bone and joint surgery. American volume.

[12]  B. B. Roe,et al.  Total Anomalous Pulmonary Venous Drainage, Technical and Physiological Considerations , 1964 .

[13]  M. McQueen,et al.  Cefuroxime in total joint arthroplasty. Intravenous or in bone cement. , 1990, The Journal of arthroplasty.

[14]  B. Bergman,et al.  Ultraviolet radiation compared to an ultra-clean air enclosure. Comparison of air bacteria counts in operating rooms. , 1991, The Journal of bone and joint surgery. British volume.

[15]  Goldner Jl,et al.  Ultraviolet light in orthopedic operating rooms at Duke University. Thirty-five years' experience, 1937-1973. , 1973 .