Artifacts in Spiral X-ray CT Scanners: Problems and Solutions

Artifact is one of the most important factors in degrading the CT image quality and plays an important role in diagnostic accuracy. In this paper, some artifacts typically appear in Spiral CT are introduced. The different factors such as patient, equipment and interpolation algorithm which cause the artifacts are discussed and new developments and image processing algorithms to prevent or reduce them are presented. Keywords—CT artifacts, Spiral CT, Artifact removal.

[1]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[2]  Cameron J. Ritchie,et al.  Respiratory compensation in projection imaging using a magnification and displacement model , 1996, IEEE Trans. Medical Imaging.

[3]  Hidemitsu Ogawa Image Reconstruction From Incomplete Projections , 1982, Other Conferences.

[4]  Wang,et al.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction , 1999, Microscopy and Microanalysis.

[5]  Willi A. Kalender,et al.  Algorithms for the reduction of CT artifacts caused by metallic implants , 1990, Medical Imaging.

[6]  C C Ling,et al.  CT-assisted assessment of bladder and rectum dose in gynecological implants. , 1987, International journal of radiation oncology, biology, physics.

[7]  Rainer Raupach,et al.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. , 2003, Investigative radiology.

[8]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[9]  G. Herman Correction for beam hardening in computed tomography. , 1979, Physics in medicine and biology.

[10]  K. Taguchi,et al.  Algorithm for image reconstruction in multi-slice helical CT. , 1998, Medical physics.

[11]  Cyrill Burger,et al.  Respiration-induced attenuation artifact at PET/CT: technical considerations. , 2003, Radiology.

[12]  Peter Aundal Toft,et al.  A very fast implementation of 2D iterative reconstruction algorithms , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[13]  D. Robertson,et al.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. , 1997, Journal of computer assisted tomography.

[14]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[15]  E. Fishman,et al.  Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. , 1988, Journal of computer assisted tomography.

[16]  J. Hsieh Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.

[17]  M. Defrise,et al.  Iterative reconstruction for helical CT: a simulation study. , 1998, Physics in medicine and biology.

[18]  W. Kalender,et al.  Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. , 2001, Medical physics.

[19]  N. Ebraheim,et al.  Reduction of postoperative CT artifacts of pelvic fractures by use of titanium implants. , 1990, Orthopedics.

[20]  P M Joseph,et al.  A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine. , 1997, Medical physics.

[21]  Terry M. Peters Computed Tomography: Fundamentals, System Technology, Image quality and Applications , 2001 .